A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity

被引:558
|
作者
Bouten, CVC
Koekkoek, KTM
Verduin, M
Kodde, R
Janssen, JD
机构
[1] University of Technology, Division of Computational and Experimental Mechanics, Eindhoven 5600 MB
[2] University of Technology, Division of Computational and Experimental Mechanics
关键词
assessment of daily physical activity; data processing unit; energy expenditure; physical activity; piezoresistive accelerometer; portable unit; triaxial accelerometer;
D O I
10.1109/10.554760
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present study describes the development of a triaxial accelerometer (TA) and a portable data processing unit for the assessment of daily physical activity. The TA is composed of three orthogonally mounted uniaxial piezoresistive accelerometers and can be used to register accelerations covering the amplitude and frequency ranges of human body acceleration, Interinstrument and test-retest experiments showed that the offset and the sensitivity of the TA were equal for each measurement direction and remained constant on two measurement days, Transverse sensitivity was significantly different for each measurement direction, but did not influence accelerometer output (<3% of the sensitivity along the main axis), The data unit enables the on-line processing of accelerometer output to a reliable estimator of physical activity over eight-day periods, Preliminary evaluation of the system in 13 male subjects during standardized activities in the laboratory demonstrated a significant relationship between accelerometer output and energy expenditure due to physical activity, the standard reference for physical activity (r = 0.89), Shortcomings of the system are its low sensitivity to sedentary activities and the inability to register static exercise. The validity of the system for the assessment of normal daily physical activity and specific activities outside the laboratory should be studied in free-living subjects.
引用
收藏
页码:136 / 147
页数:12
相关论文
共 50 条
  • [1] Detection of daily physical activities using a triaxial accelerometer
    M. J. Mathie
    A. C. F. Coster
    N. H. Lovell
    B. G. Celler
    [J]. Medical and Biological Engineering and Computing, 2003, 41 : 296 - 301
  • [2] Detection of daily physical activities using a triaxial accelerometer
    Mathie, MJ
    Coster, ACF
    Lovell, NH
    Celler, BG
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (03) : 296 - 301
  • [3] Validation of the RT3 triaxial accelerometer for the assessment of physical activity
    Rowlands, AV
    Thomas, PWM
    Eston, RG
    Topping, R
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (03): : 518 - 524
  • [4] PHYSICAL ACTIVITY IN ADULTS ASSESSED BY THE TRIAXIAL ACCELEROMETER
    Dung, Nguyen Quang
    Khan, Nguyen Cong
    Tabata, Izumi
    [J]. ANNALS OF NUTRITION AND METABOLISM, 2009, 55 : 308 - 308
  • [5] Comparison of Physical Activity Recall with Triaxial Accelerometer
    Lee, Dong Ju
    Oh, Seung Min
    Park, Jin Ho
    Kim, Ju Young
    Yoo, Tai Woo
    [J]. KOREAN JOURNAL OF FAMILY MEDICINE, 2005, 26 (02): : 74 - 80
  • [6] ASSESSMENT OF PHYSICAL ACTIVITY USING A NEW TRIAXIAL ACCELEROMETER (ACTIVTRACER) IN JAPANESE ADULTS
    Oguma, Y.
    Onishi, S.
    Katsukawa, F.
    Kinoshita, N.
    Yamamoto, S.
    Ishida, H.
    Lee, I. M.
    Yamazaki, H.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S252 - S252
  • [7] ASSESSMENT OF ENERGY-EXPENDITURE FOR PHYSICAL-ACTIVITY USING A TRIAXIAL ACCELEROMETER
    BOUTEN, CV
    WESTERTERP, KR
    VERDUIN, M
    JANSSEN, JD
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1994, 26 (12): : 1516 - 1523
  • [8] Re-examination of accelerometer data processing and calibration for the assessment of physical activity intensity
    Arvidsson, Daniel
    Fridolfsson, Jonatan
    Borjesson, Mats
    Andersen, Lars Bo
    Ekblom, Orjan
    Dencker, Magnus
    Brond, Jan Christian
    [J]. SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2019, 29 (10) : 1442 - 1452
  • [9] Evaluation of the Physical Activity of Anesthesiologists in the Operating Room During Daily Work Using a Triaxial Accelerometer
    Tanaka, Hidenori
    Kawamata, Tomoyuki
    Gen-No, Hirokazu
    Nose, Hiroshi
    Kawamata, Mikito
    [J]. ARCHIVES OF ENVIRONMENTAL & OCCUPATIONAL HEALTH, 2015, 70 (02) : 77 - 80
  • [10] Significance of Lifestyle Activity in Daily Life Assessed by Triaxial Accelerometer
    Oshima, Yoshitake
    Kawaguchi, Kaori
    Doi, Ryosuke
    Ohkawara, Kazunori
    Hikihara, Yuki
    Ishikawa-Takata, Kazuko
    Tanaka, Shigeho
    Ebine, Naoyuki
    Aoki, Kazuo
    Misumi, Junichi
    Tabata, Izumi
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S250 - S250