Effect of external electrode arrangements on R-134a two-phase flow regimes in the presence of AC electric fields

被引:12
|
作者
Hanafizadeh, Pedram [1 ]
Ahmadi, Sadegh [1 ]
Zeraati, Shahab [1 ]
Gharahasanlo, Mahla [1 ]
Akhavan-Behabadi, M. A. [1 ]
机构
[1] Univ Tehran, Coll Engn, Sch Mech Engn, CEDOES, POB 11155-4563, Tehran 111554563, Iran
基金
美国国家科学基金会;
关键词
Experimental investigation; AC electric field; Tow-phase; External electrode arrangements; Flow pattern; HEAT-TRANSFER ENHANCEMENT; ELECTROHYDRODYNAMIC ENHANCEMENT; MASS FLUX; EHD; VOLTAGE; PATTERN;
D O I
10.1016/j.applthermaleng.2017.05.030
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, two-phase flow regime redistribution in a horizontal tube within which two-phase flow of refrigerant R-134a is passing under the influence of high-voltage AC electric fields is experimentally investigated. The experimental study deals with the effects of external position for double electrodes, external arrangements for triple electrodes and using alternative refrigerant. A theoretical Steiner tube two-phase flow pattern map for external double electrode arrangement in the horizontal tube under flow conditions with mass fluxes of 30-530 kg/m(2) s, inlet qualities from 0% to 90% and fixed applied voltage of 9.8 kV is developed. The results show that by intensifying the applied electric field and increasing the vapor quality, the volume of the liquid splashed on the tube wall increases. It is found that electrode arrangements substantially affect on the two-phase flow pattern. Based on these results, because of the difference between the created electric field of the various electrode arrangements, the number of generated bubbles and their density in arrangement #2 is significantly less than arrangement #1. Also the results indicate that because of the uniformity of electric field, the number of the generated bubbles and their density in electrode arrangement #5 is more than all of the electrode arrangements. Eventually, the effect of using refrigerant R-600a rather than R-134a is studied. It was observed that because of low difference between liquid and vapor electric permittivity for R-600a, applying AC high-voltage on R-600a two-phase flow has not any impact on two-phase flow regime redistribution. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:503 / 514
页数:12
相关论文
共 50 条
  • [31] Two-phase flow visualization and pressure drop measurements of HFO-1234yf and R-134a refrigerants in horizontal return bends
    Padilla, Miguel
    Revellin, Remi
    Bonjour, Jocelyn
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 39 : 98 - 111
  • [32] Numerical investigation of EHD effects on heat transfer enhancement and flow pattern of R-134a two phase flow
    Hanafizadeh, Pedram
    Gharahasanlo, Mahla
    Ahmadi, Sadegh
    Zeraati, Shahab
    Akhavan-Behabadi, M. A.
    JOURNAL OF ELECTROSTATICS, 2016, 82 : 63 - 71
  • [33] Two-phase flow condensation heat transfer characteristics of R-134a inside three-dimensional cylindrical micropillar enhanced tube
    Kumar, Anil
    Kumar, Ravi
    Das, Arup Kumar
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 159 : 88 - 98
  • [34] INVESTIGATING MICRO-FIN AND SMOOTH TUBES IN HORIZONTAL TWO-PHASE FLOW BOILING USING R-1234ze and R-134a REFRIGERANTS
    Abdul, Kaggwa
    Wang, Chi-chuan
    4TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2016, : 104 - 111
  • [35] Flow boiling of R-22, R-134a and CO2 in horizontal evaporator with minichannels -: Part 2:: Two-phase flow boiling heat transfer
    Choi, Kwang-Il
    Pamitran, Agus Sunjarianto
    Oh, Jong-Taek
    Oh, Hoo-Kyu
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 687 - +
  • [36] Flow regimes and two-phase pressure gradient in horizontal straight tubes: Experimental results for HFO-1234yf, R-134a and R-410A (vol 35, pg 1113, 2011)
    Padilla, Miguel
    Revellin, Remi
    Haberschill, Philippe
    Bensafi, Ahmed
    Bonjour, Jocelyn
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 40 : 195 - 197
  • [37] Two-phase flow visualization of R134A in a multiport microchannel tube
    Niño, VG
    Hrnjak, PS
    Newell, TA
    HEAT TRANSFER ENGINEERING, 2003, 24 (01) : 41 - 52
  • [38] Effect of EHD on heat transfer enhancement during two-phase condensation of R-134a at high mass flux in a horizontal smooth tube
    Laohalertdecha, Suriyan
    Wongwises, Somchai
    HEAT AND MASS TRANSFER, 2007, 43 (09) : 871 - 880
  • [39] Experimental study on two-phase condensation heat transfer and pressure drop of R-134a flowing in a dimpled tube
    Aroonrat, Kanit
    Wongwises, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 106 : 437 - 448
  • [40] Effect of EHD on heat transfer enhancement during two-phase condensation of R-134a at high mass flux in a horizontal smooth tube
    Suriyan Laohalertdecha
    Somchai Wongwises
    Heat and Mass Transfer, 2007, 43 : 871 - 880