Continuous measurement of cardiac output using stochastic system identification techniques

被引:0
|
作者
Yelderman, M [1 ]
机构
[1] Monterey Med Solut, CEO, Monterey, CA USA
来源
PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7 | 2004年 / 26卷
关键词
system theory; patient monitoring; continuous cardiac output; stochastic;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Indicator dilutions techniques offer the most reliable methods of determining clinical cardiac output because of the elastic nature of the cardiac vessels. A catheter-mounted heating filament affords a simple means of supplying "heat" indicator, but is power and temperature limited because of possible patient injury. A stochastic signal processing method using pseudorandom binary infusion of heat offers a process of enhancing the signal to noise sufficiently to facilitate a computation of cardiac output over a reasonable time period (5 min) with a clinically acceptable error.
引用
收藏
页码:5360 / 5362
页数:3
相关论文
共 50 条
  • [21] Continuous cardiac output measurement by thermodeprivation is unsatisfactory in cardiac surgical patients
    Uesugi, F
    Inada, T
    Inada, K
    Kawachi, S
    Matsuda, M
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (03) : 442 - 444
  • [22] IS CONTINUOUS CARDIAC-OUTPUT MEASUREMENT USING THERMODILUTION RELIABLE IN THE CRITICALLY ILL PATIENT
    BOLDT, J
    MENGES, T
    WOLLBRUCK, M
    HAMMERMANN, H
    HEMPELMANN, G
    CRITICAL CARE MEDICINE, 1994, 22 (12) : 1913 - 1918
  • [23] USCOM: an accurate system for cardiac output measurement?
    P Lichtenthal
    R Phillips
    J Sloniger
    J Copeland
    Critical Care, 9 (Suppl 1):
  • [24] ONLINE MONITORING-SYSTEM FOR CONTINUOUS AND REAL-TIME MEASUREMENT OF CARDIAC-OUTPUT
    TACHIMORI, Y
    TAKEZAWA, J
    OKADA, T
    FUKUI, S
    TAKAHASHI, H
    TAENAKA, N
    YOSHIYA, I
    CRITICAL CARE MEDICINE, 1986, 14 (04) : 401 - 401
  • [25] Continuous cardiac output measurement by arterial pulse contour analysis: Accuracy under changes in cardiac output?
    Reuter, DA
    Ehrmann, Z
    Felbinger, TW
    Kilger, E
    Goedje, O
    Meier-Hellmann, AD
    Pfeiffer, UJ
    Goetz, AE
    CRITICAL CARE MEDICINE, 2000, 28 (12) : A71 - A71
  • [26] NONINVASIVE CONTINUOUS MEASUREMENT OF THE CARDIAC-OUTPUT WITH ULTRASOUND (ACCUCOM)
    KLEIN, G
    LEUWER, M
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1987, 28 (06): : 189 - 193
  • [27] Cardiac arrhythmias related to continuous thermodilution cardiac output measurement in an anaesthetized sheep
    Coppens, P.
    Moens, Y.
    LABORATORY ANIMALS, 2009, 43 (03) : 291 - 294
  • [28] CONTINUOUS CARDIAC-OUTPUT MEASUREMENT BY MODIFIED THERMODILUTION CATHETER
    KATAYAMA, M
    SEKII, S
    MIYASAKA, K
    CRITICAL CARE MEDICINE, 1986, 14 (04) : 364 - 364
  • [29] Measurement of continuous cardiac output useful for the management of polytrauma patients?
    Stiletto, R
    Hünerkopf, M
    Schnabel, M
    Gotzen, L
    Baacke, M
    UNFALLCHIRURG, 2001, 104 (11): : 1043 - 1047
  • [30] CATHETER SEMICONDUCTOR RADIATION DETECTOR FOR CONTINUOUS MEASUREMENT OF CARDIAC OUTPUT
    UEDA, H
    SASAKI, Y
    IIO, M
    KAIHARA, S
    MACHIDA, K
    ITO, I
    TAKAYANA.SI
    KABAYASH.T
    SUGITA, T
    JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (12) : 713 - &