AFODSS: Heart Rate Estimation Method From Photoplethysmographic Signals With Motion Artifacts Using Fourier-Sparse Dual Optimization

被引:3
|
作者
Raj, Remya [1 ]
Selvakumar, J. [1 ]
Maik, Vivek [1 ]
机构
[1] SRM Inst Sci & Technol, Dept Elect & Commun Engn, Kattankulathur 603203, India
关键词
Heart rate; Estimation; Signal processing algorithms; Acceleration; Sensors; Biomedical monitoring; Fourier series; Photoplethysmography; Adaptive Fourier Decomposition; Multi Measurement Model(MMV); Bi-Conjugate Gradient; FOCUSS Method; FRAMEWORK; ALGORITHM;
D O I
10.1109/JSEN.2019.2928643
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Precise heart rate (HR) estimation of individuals during physical exercise from PPG sensors using direct methods often produces erroneous output due to the occurrence of exceedingly high motion artifacts (MAs). The effect of MAs can be neutralized using non-direct algorithms such as optimization techniques using some a priori about MA. In this paper, we propose a dual-optimization technique using adaptive Fourier decomposition in conjunction with sparse spectral reconstruction (AFODSS) using a multiple measurement vectors (MMVs) model and a regularized bi-conjugate gradient focal underdetermined system solver (BCG-FOCUSS) algorithm. Using AFODSS, the average absolute error (AAE) of HR obtained on the dataset recorded from 23 subjects during their intense exercise is 1.35 beats/min. The BCG-FOCUSS algorithm used in this paper helps to speed up the convergence rate and reduce time complexity when compared with other FOCUSS algorithms.
引用
收藏
页码:9953 / 9963
页数:11
相关论文
共 46 条
  • [1] A Robust Heart Rate Monitoring Scheme Using Photoplethysmographic Signals Corrupted by Intense Motion Artifacts
    Khan, Emroz
    Al Hossain, Forsad
    Uddin, Shiekh Zia
    Alam, S. Kaisar
    Hasan, Md. Kamrul
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (03) : 550 - 562
  • [2] Utilization of Adaptive-coefficient Estimation Method for Motion Artifacts Reduction from Photoplethysmographic Signals
    Ram, M. Raghu
    Sivani, K.
    Reddy, K. Ashoka
    [J]. PROCEEDINGS OF THE 2016 IEEE INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS, SIGNAL PROCESSING AND NETWORKING (WISPNET), 2016, : 818 - 822
  • [3] A New Framework to Extract Heart Rate Information from Photoplethysmographic (PPG) Signals with Strong Motion Artifacts
    Zhang, Zi-Hao
    Liu, Jian
    Wu, Xiao-Yue
    Wang, Chao-Ying
    Yang, Ran
    [J]. TENCON 2015 - 2015 IEEE REGION 10 CONFERENCE, 2015,
  • [4] Heart Rate Measurement from Motion Compensated Photoplethysmographic Signals
    Savaskan, Deniz Alp
    Mahanoglu, Alihan
    Soner, Burak
    Kholmatov, Alisher
    [J]. 2020 28TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2020,
  • [5] Determination of Absolute Heart Beat from Photoplethysmographic Signals in the Presence of Motion Artifacts
    Karna, Viswavardhan Reddy
    Kumar, Navin
    [J]. 2018 SECOND INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRONICS, COMPUTERS AND COMMUNICATIONS (ICAECC), 2018,
  • [6] Harmonic sum-based method for heart rate estimation using PPG signals affected with motion artifacts
    Dubey, Harishchandra
    Kumaresan, Ramdas
    Mankodiya, Kunal
    [J]. JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2018, 9 (01) : 137 - 150
  • [7] Harmonic sum-based method for heart rate estimation using PPG signals affected with motion artifacts
    Harishchandra Dubey
    Ramdas Kumaresan
    Kunal Mankodiya
    [J]. Journal of Ambient Intelligence and Humanized Computing, 2018, 9 : 137 - 150
  • [8] Heart Rate Estimation during Exercise from Photoplethysmographic Signals Using Convolutional Neural Network
    Nakamura, Masaki
    Sato, Takashi
    [J]. 2019 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS 2019), 2019,
  • [9] Robust Heart Rate Estimation During Physical Exercise Using Photoplethysmographic Signals
    Motin, Mohammod Abdul
    Karmakar, Chandan Kumar
    Palaniswami, Marimuthu
    [J]. 2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 494 - 497
  • [10] A Particle Filter Framework for the Estimation of Heart Rate from ECG Signals Corrupted by Motion Artifacts
    Nathan, Viswam
    Akkaya, Ilge
    Jafari, Roozbeh
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6560 - 6565