Experimental aerothermal characterization of surface air-cooled oil coolers for turbofan engines

被引:8
|
作者
Broatch, A. [1 ]
Olmeda, P. [1 ]
Garcia-Tiscar, J. [1 ]
Felgueroso, A. [1 ]
Chavez-Modena, M. [2 ]
Gonzalez, L. M. [2 ]
Gelain, M. [3 ]
Couilleaux, A. [3 ]
机构
[1] Univ Politecn Valencia, CMT Motores Term, Camino Vera, Valencia 46022, Spain
[2] Univ Politecn Madrid, ETSIAE Sch Aeronaut, Plaza Cardenal Cisneros 3, Madrid 28040, Spain
[3] Safran Aircraft Engines, F-77550 Rond Point Rene Ravaud, Moissy Cramayel, France
基金
欧盟地平线“2020”;
关键词
Aero engines; Experimental aerodynamics; Heat exchangers; Turbomachinery; Thermal management; SACOC; HEAT-EXCHANGERS; PERFORMANCE; FIN; GENERATION;
D O I
10.1016/j.ijheatmasstransfer.2022.122775
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal management is a major challenge for new generation turbofan aero-engines. One of the most promising heat exchangers are the so-called surface air-cooled oil coolers (SACOCs). In this study, an ex-perimental methodology is proposed and implemented in order to characterize SACOCs mounted in tur-bofan bypass ducts. Three different SACOC geometries have been characterized under the same nominal operating point, while the actual velocity profile in the bypass was reproduced by means of a distortion screen upstream the test section. The heat exchangers were mounted in counterflow configuration and feature the same fin geometry in the oil side. The three prototypes varied only in the air side, being the first a baseline flat plate, the second a SACOC with standard trapezoidal fins and the third featuring opti-mized fins designed to reduce the pressure drop. Aerothermal results demonstrated that the effect of the SACOC on the bypass flow was confined to a region about the same height and width of the finned area, avoiding the need of reproducing the whole bypass duct. However, for this reduced-height experimental approach to be valid, we show that the velocity profile needs to be rearranged to match the specific sec-tion of the whole bypass. We also demonstrate how the optimized fin geometry achieved a 10% lower friction factor than the standard one at nominal flow conditions while increasing the overall heat transfer coefficient by 5.2%.(c) 2022 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Experimental Study on the Performance of Air-Cooled Condensing Unit in Groove
    Zhao, An-qiang
    Li, Qiong
    Meng, Qing-wei
    Meng, Qing-lin
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENTAL ENGINEERING (SEEE 2016), 2016,
  • [22] EXPERIMENTAL RESULTS OF FULL SCALE AIR-COOLED TURBINE TESTS
    NOUSE, H
    YAMAMOTO, A
    YOSHIDA, T
    NISHIMURA, H
    TAKAHARA, K
    TORISAKI, T
    MATSUKI, M
    JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1976, 98 (01): : 103 - 113
  • [23] Theoretical and experimental analyses of mist precooling for an air-cooled chiller
    Yu, F. W.
    Ho, W. T.
    Chan, K. T.
    Sit, R. K. Y.
    APPLIED THERMAL ENGINEERING, 2018, 130 : 112 - 119
  • [24] Numerical simulation and experimental study of the air-cooled motorized spindle
    He Qiang
    Shen Yuan
    Ren Fengzhang
    Li Lili
    Alex, A. Volinsky
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2017, 231 (12) : 2357 - 2369
  • [25] DETAILED CHARACTERIZATION OF COMPLEX BANDING IN AIR-COOLED BAINITIC STEELS
    Morales-Rivas, L.
    Roelofs, H.
    Hasler, S.
    Garcia-Mateo, C.
    Caballero, F. G.
    JOURNAL OF MINING AND METALLURGY SECTION B-METALLURGY, 2015, 51 (01) : 25 - 32
  • [26] Deutz' New B/FL 513 Series of Air-Cooled Diesel Engines.
    Ungeringer, Gerd
    Garthe, Hellmut
    MTZ Motortechnische Zeitschrift, 1984, 45 (12) : 525 - 526
  • [27] EVALUATION OF LUBRICANTS FOR JAPANESE SMALL AIR-COOLED TWO-CYCLE ENGINES.
    Maeda, T.
    Tanabe, T.
    Maeda, Y.
    Tamura, K.
    1979, (790076):
  • [28] Characterization and evaluation of the hydraulic activity of water-cooled slag and air-cooled slag
    Mostafa, NY
    El-Hemaly, SAS
    Al-Wakeel, EI
    El-Korashy, SA
    Brown, PW
    CEMENT AND CONCRETE RESEARCH, 2001, 31 (06) : 899 - 904
  • [29] Performance analysis of an R744 ground source heat pump system with air-cooled and water-cooled gas coolers
    Hu, Haitao
    Eikevik, Trygve Magne
    Neksa, Petter
    Hafner, Armin
    Ding, Guoliang
    Huang, Qingnan
    Ye, Jingjing
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 63 : 72 - 86
  • [30] Experimental Investigation of the Flow Maldistribution Inside an Air-Cooled Heat Exchanger
    M. A. Habib
    S. A. Said
    A. Khalifa
    M. A. Nemitallah
    T. Ayinde
    Arabian Journal for Science and Engineering, 2014, 39 : 8187 - 8198