eBP: An Ear-Worn Device For Frequent and Comfortable Blood Pressure Monitoring

被引:0
|
作者
Bui, Nam [1 ]
Pham, Nhat [2 ]
Barnitz, Jessica Jacqueline [1 ]
Zou, Zhanan [1 ]
Nguyen, Phuc [3 ]
Truong, Hoang [1 ]
Kim, Taeho [1 ]
Farrow, Nicholas [1 ]
Nguyen, Anh [1 ]
Xiao, Jianliang [1 ]
Deterding, Robin [4 ]
Dinh, Thang [5 ]
Vu, Tam [1 ,2 ]
机构
[1] Univ Colorado, Boulder, CO 80309 USA
[2] Univ Oxford, Oxford, England
[3] Univ Texas Arlington, Arlington, TX 76019 USA
[4] Childrens Hosp Colorado, Boulder, CO USA
[5] Virginia Commonwealth Univ, Richmond, VA USA
关键词
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Frequent blood pressure monitoring is the key to diagnosis and treatments of many severe diseases. However, the conventional ambulatory methods require patients to carry a blood pressure (BP) monitoring device for 24 h and conduct the measurement every 10-15 min. Despite their extensive usage, wearing the wrist/arm-based BP monitoring device for a long time has a significant impact on users' daily activities. To address the problem, we developed eBP to measure blood pressure (BP) from inside user's ear aiming to minimize the measurement's impact on users' normal activities although maximizing its comfort level. The key novelty of eBP includes (1) a light-based inflatable pulse sensor which goes inside the ear, (2) a digital air pump with a fine controller, and (3) BP estimation algorithms that eliminate the need of blocking the blood flow inside the ear. Through the comparative study of 35 subjects, eBP can achieve the average error of 1.8 mmHg for systolic (high-pressure value) and -3.1 mmHg for diastolic (low-pressure value) with the standard deviation error of 7.2 mmHg and 7.9 mmHg, respectively. These results satisfy the FDA's AAMI standard, which requires a mean error of less than 5 mmHg and a standard deviation of less than 8 mmHg.
引用
收藏
页码:118 / 125
页数:8
相关论文
共 50 条
  • [41] Continuous Blood Pressure Monitoring using Wrist-worn Bio-impedance Sensors with Wet Electrodes
    Ibrahim, Bassem
    Jafari, Roozbeh
    [J]. 2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 251 - 254
  • [42] More Frequent Remote Home Monitoring Decreases Blood Pressure in an Unselected Population of People With Diabetes
    Xu, Karen
    James, Roberta
    Lu, Wei
    Sangha, Anoop
    Shah, Bimal R.
    [J]. CIRCULATION, 2019, 140
  • [43] Reproducibility of nighttime home blood pressure measured by a wrist-type nocturnal home blood pressure monitoring device
    Tomitani, Naoko
    Kanegae, Hiroshi
    Kario, Kazuomi
    [J]. JOURNAL OF CLINICAL HYPERTENSION, 2021, 23 (10): : 1872 - 1878
  • [44] FEASIBILITY OF WATCH-TYPE CUFF-LESS BLOOD PRESSURE MEASUREMENT DEVICE IN DAILY BLOOD PRESSURE MONITORING
    Lee, Youngro
    Seo, Jongmo
    Lee, Haeyoung
    [J]. JOURNAL OF HYPERTENSION, 2024, 42
  • [45] A NEW PROGRAMMABLE HOME BLOOD PRESSURE MONITORING DEVICE FOR THE ASSESSMENT OF NIGHTTIME BLOOD PRESSURE OF TOTAL 40 NORMOTENSIVE SUBJECTS
    Ishigami, T.
    Ushio, H.
    Minegishi, S.
    Araki, N.
    Umemura, M.
    Tamura, K.
    Uchino, K.
    Umemura, S.
    [J]. JOURNAL OF HYPERTENSION, 2010, 28 : E208 - E208
  • [46] Wearable device for continuously blood pressure monitoring enable atrial fibrillation risk
    Guo, Y.
    Zhang, H.
    [J]. EUROPEAN HEART JOURNAL, 2022, 43 : 2811 - 2811
  • [47] An acute hypertensive episode triggered by an ambulatory blood-pressure-monitoring device
    Yosefy, C
    Vaturi, M
    Levine, RA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (22): : 2315 - 2316
  • [48] In vitro and in vivo evaluation of an oscillometric device for monitoring blood pressure in dialysis patients
    Lodi, Carlo Alberto
    Estridge, Charles
    Ghidini, Carlo
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (10) : 2950 - 2961
  • [49] Validation of a noninvasive blood pressure monitoring device in pediatric intensive care patients
    Wankum, PC
    Thurman, TL
    Holt, SJ
    Hall, RA
    Simpson, PM
    Heulitt, MJ
    [J]. SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1944 - 1945
  • [50] Development of bioimpedance sensing device for wearable monitoring of the aortic blood pressure curve
    Koiv, H.
    Rist, M.
    Min, M.
    [J]. TM-TECHNISCHES MESSEN, 2018, 85 (05) : 366 - 377