Needle-free connectors catheter-related bloodstream infections: a prospective randomized controlled trial

被引:12
|
作者
Koeppen, Michael [1 ]
Weinert, Franziska [2 ]
Oehlschlaeger, Sabrina [3 ]
Koerner, Andreas [1 ]
Rosenberger, Peter [1 ]
Haeberle, Helene Anna [1 ]
机构
[1] Univ Klinikum Tubingen, Dept Anesthesiol & Intens Care Med, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Klinikum Sindelfingen Boblingen, Dept Anesthesiol, Boblingen, Germany
[3] Univ Hosp, Dept Cardiac Surg, Tubingen, Germany
关键词
Needle-free connectors; Catheter-related bloodstream infections; Bionecteur (R); INCREASE;
D O I
10.1186/s40635-019-0277-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background In the critically ill, catheter-related bloodstream infection can result from bacterial contamination of infusion hubs of intravascular catheters. Needle-free connectors (NFC) have been suggested to reduce the rate of bacterial contamination and subsequent catheter-related bloodstream infection (CRBSI), but data remains ambiguous. Thus, we tested if a novel NFC would reduce bacterial contamination and subsequent CRBSI. Results In a prospective, randomized controlled trial, surgical ICU patients were randomized to three-way hubs closed by caps or Bionecteur (R) (Vygon, Inc.) of central venous catheters. Every 72 h, infusion lines were renewed and microbiological samples were taken. Bacterial growth was analyzed by blinded microbiologists. Incidence of bacterial contamination and CRSBI were assessed. Outcome parameters like length of stay on ICU and outcome were retrospectively assessed. Two thousand seven hundred patients were screened, 111 were randomized to the NFC, and 109 into the control group. Finally, 24 patients in the NFC and 23 control patients were analyzed. The majority of samples (NFC 77%; control 70%) found no bacterial growth. Coagulase-negative staphylococci were most commonly detected on CVC samples (NFC 17%; control 21%). We found CRBSI (defined as identical pathogens in blood culture and catheter line tip culture, and clinical manifestations of infection) in two control patients and one patient of the NFC group. Their length of ICU stay did not differ between groups (NFC 19 days; control 23 days). Conclusion The use of NFC does not influence the rate of bacterial contamination of infusion hubs of central venous catheters.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Impact of MaxZero™ needle-free connector on the incidence of central venous catheter-related infections in surgical intensive care unit
    Clavier, Thomas
    Ferguen, Mathias
    Gouin, Philippe
    Gillibert, Andre
    Dusenne, Mikael
    Merle, Veronique
    Veber, Benoit
    AUSTRALIAN CRITICAL CARE, 2019, 32 (02) : 107 - 111
  • [32] Catheter-related thrombosis in adults with cancer: a secondary analysis of a prospective randomized controlled trial
    Hapgood, Greg
    Hill, Kate
    Okano, Satomi
    Abro, Emad
    Looke, David
    Kennedy, Glen
    Pavilion, Gilbert
    Van Kuilenburg, Rosita
    Geary, Alanna
    Joubert, Warren
    Eastgate, Melissa
    Jones, Mark
    Mollee, Peter
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2025, 23 (02) : 627 - 634
  • [33] Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter - A randomized, controlled trial
    Maki, DG
    Stolz, SM
    Wheeler, S
    Mermel, LA
    ANNALS OF INTERNAL MEDICINE, 1997, 127 (04) : 257 - +
  • [34] Central venous catheter-related bloodstream infections in patients with hematological malignancies: Comparison of data from a clinical registry and a randomized controlled trial
    Schalk, Enrico
    Teschner, Daniel
    Hentrich, Marcus
    Boell, Boris
    Panse, Jens
    Schmidt-Hieber, Martin
    Vehreschild, Maria J. G. T.
    Biehl, Lena M.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2020, 41 (02): : 254 - 256
  • [35] FACTORS INFLUENCING THE ETIOLOGY OF PRIMARY BLOODSTREAM AND CATHETER-RELATED BLOODSTREAM INFECTIONS
    Alcaraz, R.
    Palomar, M.
    Otal, J.
    Olaechea, P.
    Alvarez Lerma, F.
    Ballesteros, J. C.
    Soto, J. M.
    Lopez Pueyo, M. J.
    INTENSIVE CARE MEDICINE, 2009, 35 : 270 - 270
  • [36] Prevention of central venous catheter-related bloodstream infections
    Rupp, ME
    Craig, R
    INFECTIONS IN MEDICINE, 2004, 21 (03) : 123 - 127
  • [37] Uncommon aetiological agents of catheter-related bloodstream infections
    Reigadas, E.
    Rodriguez-Creixems, M.
    Sanchez-Carrillo, C.
    Martin-Rabadan, P.
    Bouza, E.
    EPIDEMIOLOGY AND INFECTION, 2015, 143 (04): : 741 - 744
  • [38] An intervention to decrease catheter-related bloodstream infections in the ICU
    Pronovost, Peter
    Needham, Dale
    Berenholtz, Sean
    Sinopoli, David
    Chu, Haitao
    Cosgrove, Sara
    Sexton, Bryan
    Hyzy, Robert
    Welsh, Robert
    Roth, Gary
    Bander, Joseph
    Kepros, John
    Goeschel, Christine
    NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (26): : 2725 - 2732
  • [39] What is new for the prevention of catheter-related bloodstream infections?
    Lorente, Leonardo
    ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (06)