Needle-free connectors catheter-related bloodstream infections: a prospective randomized controlled trial

被引:12
|
作者
Koeppen, Michael [1 ]
Weinert, Franziska [2 ]
Oehlschlaeger, Sabrina [3 ]
Koerner, Andreas [1 ]
Rosenberger, Peter [1 ]
Haeberle, Helene Anna [1 ]
机构
[1] Univ Klinikum Tubingen, Dept Anesthesiol & Intens Care Med, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Klinikum Sindelfingen Boblingen, Dept Anesthesiol, Boblingen, Germany
[3] Univ Hosp, Dept Cardiac Surg, Tubingen, Germany
关键词
Needle-free connectors; Catheter-related bloodstream infections; Bionecteur (R); INCREASE;
D O I
10.1186/s40635-019-0277-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background In the critically ill, catheter-related bloodstream infection can result from bacterial contamination of infusion hubs of intravascular catheters. Needle-free connectors (NFC) have been suggested to reduce the rate of bacterial contamination and subsequent catheter-related bloodstream infection (CRBSI), but data remains ambiguous. Thus, we tested if a novel NFC would reduce bacterial contamination and subsequent CRBSI. Results In a prospective, randomized controlled trial, surgical ICU patients were randomized to three-way hubs closed by caps or Bionecteur (R) (Vygon, Inc.) of central venous catheters. Every 72 h, infusion lines were renewed and microbiological samples were taken. Bacterial growth was analyzed by blinded microbiologists. Incidence of bacterial contamination and CRSBI were assessed. Outcome parameters like length of stay on ICU and outcome were retrospectively assessed. Two thousand seven hundred patients were screened, 111 were randomized to the NFC, and 109 into the control group. Finally, 24 patients in the NFC and 23 control patients were analyzed. The majority of samples (NFC 77%; control 70%) found no bacterial growth. Coagulase-negative staphylococci were most commonly detected on CVC samples (NFC 17%; control 21%). We found CRBSI (defined as identical pathogens in blood culture and catheter line tip culture, and clinical manifestations of infection) in two control patients and one patient of the NFC group. Their length of ICU stay did not differ between groups (NFC 19 days; control 23 days). Conclusion The use of NFC does not influence the rate of bacterial contamination of infusion hubs of central venous catheters.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Needle-free connectors catheter-related bloodstream infections: a prospective randomized controlled trial
    Michael Koeppen
    Franziska Weinert
    Sabrina Oehlschlaeger
    Andreas Koerner
    Peter Rosenberger
    Helene Anna Haeberle
    Intensive Care Medicine Experimental, 7
  • [2] Prevention of catheter-related bloodstream infection in critically ill patients using a disinfectable, needle-free connector:: A randomized controlled trial
    Yébenes, JC
    Vidaur, L
    Serra-Prat, M
    Sirvent, JM
    Batlle, J
    Motje, M
    Bonet, A
    Palomar, M
    AMERICAN JOURNAL OF INFECTION CONTROL, 2004, 32 (05) : 291 - 295
  • [3] Do Needle-Free Connectors Prevent Catheter-Related Bloodstream Infections in Patients Receiving Hemodialysis Treatments Using Central Venous Catheters?
    Micklos, Lisa
    NEPHROLOGY NURSING JOURNAL, 2015, 42 (04) : 383 - 386
  • [4] The effects of needleless connectors on catheter-related bloodstream infections
    Btaiche, Imad F.
    Kovacevich, Debra S.
    Khalidi, Nabil
    Papke, Lorelei F.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2011, 39 (04) : 277 - 283
  • [5] Impact of needle-free connectors compared with 3-way stopcocks on catheter-related bloodstream infection rates: A meta-analysis
    Daniel Rosenthal, Victor
    AMERICAN JOURNAL OF INFECTION CONTROL, 2020, 48 (03) : 281 - 284
  • [6] Catheter-related bloodstream infections
    Sitges-Serra, A
    Girvent, M
    WORLD JOURNAL OF SURGERY, 1999, 23 (06) : 589 - 595
  • [7] Catheter-related bloodstream infections
    Jenny-Avital, Elizabeth R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (12): : 1267 - 1267
  • [8] Catheter-related Bloodstream Infections
    Antonio Sitges-Serra
    Meritxell Girvent
    World Journal of Surgery, 1999, 23 : 589 - 595
  • [9] A randomized trial on chlorhexidine dressings for the prevention of catheter-related bloodstream infections in neutropenic patients
    Biehl, L. M.
    Huth, A.
    Panse, J.
    Kraemer, C.
    Hentrich, M.
    Engelhardt, M.
    Schaefer-Eckart, K.
    Kofla, G.
    Kiehl, M.
    Wendtner, C. -M.
    Karthaus, M.
    Ullmann, A. J.
    Hellmich, M.
    Christ, H.
    Vehreschild, M. J. G. T.
    ANNALS OF ONCOLOGY, 2016, 27 (10) : 1916 - 1922
  • [10] Intravascular Catheter-Related Bloodstream Infections
    Rupp, Mark E.
    Karnatak, Rajendra
    INFECTIOUS DISEASE CLINICS OF NORTH AMERICA, 2018, 32 (04) : 765 - +