Study of Delay-line Readout for Boron Coated Straw detector

被引:0
|
作者
Yu, Hao [1 ,2 ]
Gong, Hui [2 ]
Wang, Yongqiang [3 ]
Wang, Xuewu [2 ]
Li, Jianmin [2 ]
Li, Yuanjing [2 ]
Kang, Kejun [2 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Minist Educ, Key Lab Radiat Phys & Detect Technol, Beijing 100084, Peoples R China
[3] Nuctech Co, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
He-3 detector has been widely used for security and neutron scattering. Due to 3He supply crisis, alternative thermal neutron detection technique is studied. For the adequate 10B supply and its large cross-section with thermal neutron, boron coated straw detector (BCSD) is a good choice to replace the He-3 tube. To achieve high thermal neutron detection efficiency, a BCSD module usually consists of tens of straws. The BCSD module can be read out in delay-line method. We study the principle of delay-line method, and design a delay-line based readout circuit including delay-line circuit and signal processing circuit. The simulation results and test results of the delay-line readout circuit are presented in this paper.
引用
收藏
页数:3
相关论文
共 50 条
  • [11] DELAY-LINE READOUT OF MICROCHANNEL PLATES
    SOBOTTKA, SE
    WILLIAMS, MB
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 348 - 351
  • [12] Fabrication and Signal Readout of the Si-based Delay-line Radiation Detector
    Jeong, Manhee
    Ramadoss, Subhashree
    Hammig, Mark D.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1666 - +
  • [13] High impedance discrete delay-line readout circuit for silicon strip detector
    Vind, R. P.
    Inkar, A. L.
    Choudhury, R. K.
    Nayak, B. K.
    Saxena, A.
    Thomas, R. G.
    Biswas, D. C.
    John, B. V.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (03): : 1435 - 1440
  • [14] A POSITION-SENSITIVE MICROCHANNELPLATE DETECTOR USING A DELAY-LINE READOUT ANODE
    KELLER, H
    KLINGELHOFER, G
    KANKELEIT, E
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 258 (02): : 221 - 224
  • [15] A multiplex readout method for position sensitive boron coated straw neutron detector
    Yu, Hao
    Gong, Hui
    Li, Jianmin
    Wang, Yongqiang
    Wang, Xuewu
    Li, Yuanjing
    Kang, Kejun
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 797 : 324 - 329
  • [16] Research on the delay-line readout for GEM detectors
    Zhou Yi
    Li Cheng
    [J]. CHINESE PHYSICS C, 2008, 32 : 232 - 234
  • [17] An X-ray imaging device based on a GEM detector with delay-line readout
    Zhou Yi
    Li Cheng
    Sun Yong-Jie
    Shao Ming
    [J]. CHINESE PHYSICS C, 2010, 34 (01) : 78 - 82
  • [18] Position- and time-sensitive single photon detector with delay-line readout
    Czasch, A.
    Milnes, J.
    Hay, N.
    Wicking, W.
    Jagutzki, O.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1066 - 1070
  • [19] An X-ray imaging device based on a GEM detector with delay-line readout
    周意
    李澄
    孙勇杰
    邵明
    [J]. Chinese Physics C, 2010, (01) : 78 - 82
  • [20] Position and time sensitive photon counting detector with image charge delay-line readout
    Czasch, Achim
    Dangendorf, Volker
    Milnes, James
    Schoessler, Sven
    Lauck, Ronald
    Spillmann, Uwe
    Howorth, Jon
    Jagutzki, Ottmar
    [J]. ADVANCED PHOTON COUNTING TECHNIQUES II, 2007, 6771