Study of Delay-line Readout for Boron Coated Straw detector

被引:0
|
作者
Yu, Hao [1 ,2 ]
Gong, Hui [2 ]
Wang, Yongqiang [3 ]
Wang, Xuewu [2 ]
Li, Jianmin [2 ]
Li, Yuanjing [2 ]
Kang, Kejun [2 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Minist Educ, Key Lab Radiat Phys & Detect Technol, Beijing 100084, Peoples R China
[3] Nuctech Co, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
He-3 detector has been widely used for security and neutron scattering. Due to 3He supply crisis, alternative thermal neutron detection technique is studied. For the adequate 10B supply and its large cross-section with thermal neutron, boron coated straw detector (BCSD) is a good choice to replace the He-3 tube. To achieve high thermal neutron detection efficiency, a BCSD module usually consists of tens of straws. The BCSD module can be read out in delay-line method. We study the principle of delay-line method, and design a delay-line based readout circuit including delay-line circuit and signal processing circuit. The simulation results and test results of the delay-line readout circuit are presented in this paper.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Study of delay-line readout for GEM detector
    Zhou, Yi
    Li, Cheng
    Sun, Yongjie
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 71 - 76
  • [2] A MICROSTRIP DETECTOR WITH DELAY-LINE READOUT
    BARBOSA, AF
    RIEKEL, C
    WATTECAMPS, P
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 667 - 669
  • [3] FPGA implementation of a delay-line readout system for a particle detector
    Seferiadis, G
    Pouchet, M
    Gough, MP
    [J]. MEASUREMENT, 2006, 39 (01) : 90 - 99
  • [4] Readout electronics for position sensitive boron coated straw detector
    Yu, Hao
    Gong, Hui
    Wang, Yongqiang
    Wang, Xuewu
    Li, Jianmin
    Li, Yuanjing
    Kang, Kejun
    [J]. Qinghua Daxue Xuebao/Journal of Tsinghua University, 2015, 55 (06): : 691 - 694
  • [5] PROPORTIONAL CHAMBERS WITH DELAY-LINE READOUT IN THE MD-1 DETECTOR
    AULCHENKO, VM
    BONDAR, AE
    FILIMONOV, GS
    KOLACHEV, GM
    MINAKOV, GD
    ONUCHIN, AP
    PANIN, VS
    RODYAKIN, VA
    TELNOV, VI
    ZHILICH, VN
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3): : 267 - 271
  • [6] Two-dimensional GEM imaging detector with delay-line readout
    Guedes, GP
    Breskin, A
    Chechik, R
    Vartsky, D
    Bar, D
    Barbosa, AF
    Marinho, PRB
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (03): : 473 - 483
  • [7] DELAY-LINE READOUT FOR DRIFT CHAMBERS
    KREHBIEL, H
    WARMING, P
    ELSEN, E
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1978, 156 (1-2): : 347 - 351
  • [8] DELAY-LINE READOUT FOR MULTICELL DETECTORS
    DITTA, J
    KURODA, K
    NEMOZ, C
    SILLOU, D
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 250 (03): : 539 - 542
  • [9] DELAY-LINE READOUT FOR PROPORTIONAL CHAMBERS
    RINDI, A
    PEREZMEN.V
    WALLACE, RI
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1970, 77 (02): : 325 - +
  • [10] DELAY-LINE READOUT DRIFT CHAMBERS
    ATENCIO, LG
    AMANN, JF
    BOUDRIE, RL
    MORRIS, CL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 187 (2-3): : 381 - 386