PWLS-PR: low-dose computed tomography image reconstruction using a patch-based regularization method based on the penalized weighted least squares total variation approach

被引:5
|
作者
Fu, Jing [1 ,2 ]
Feng, Fei [3 ]
Quan, Huimin [2 ]
Wan, Qian [1 ,4 ]
Chen, Zixiang [1 ]
Liu, Xin [1 ]
Zheng, Hairong [1 ]
Liang, Dong [1 ]
Cheng, Guanxun [3 ]
Hu, Zhanli [1 ]
机构
[1] Chinese Acad Sci, Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Shenzhen, Peoples R China
[2] Hunan Univ, Coll Elect & Informat Engn, Changsha, Peoples R China
[3] Peking Univ Shenzhen Hosp, Dept Radiol, Shenzhen, Peoples R China
[4] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen, Peoples R China
关键词
Lose-dose computed tomography (lose-dose CT); image reconstruction; patch regularization; penalized weighted least squares (PWLS); total variation (TV); LIMITED-ANGLE DATA; NOISE-REDUCTION; ARTIFACT REDUCTION; CT RECONSTRUCTION; SUPERRESOLUTION; MULTISLICE; STRATEGIES; CONTRAST; QUALITY; FILTERS;
D O I
10.21037/qims-20-963
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Radiation exposure computed tomography (CT) scans and the associated risk of cancer in patients have been major clinical concerns. Existing research can achieve low-dose CT imaging by reducing the X-ray current and the number of projections per rotation of the human body. However, this method may produce excessive noise and fringe artifacts in the traditional filtered back projection (FBP)-reconstructed image. Methods: To solve this problem, iterative image reconstruction is a promising option to obtain high-quality images from low-dose scans. This paper proposes a patch-based regularization method based on penalized weighted least squares total variation (PWLS-PR) for iterative image reconstruction. This method uses neighborhood patches instead of single pixels to calculate the nonquadratic penalty. The proposed regularization method is more robust than the conventional regularization method in identifying random fluctuations caused by sharp edges and noise. Each iteration of the proposed algorithm can be described in the following three steps: image updating via the total variation based on penalized weighted least squares (PWLS-TV), image smoothing, and pixel-by-pixel image fusion. Results: Simulation and real-world projection experiments show that the proposed PWLS-PR algorithm achieves a higher image reconstruction performance than similar algorithms. Through the qualitative and quantitative evaluation of simulation experiments, the effectiveness of the method is also verified. Conclusions: Furthermore, this study shows that the PWLS-PR method reduces the amount of projection data required for repeated CT scans and has the useful potential to reduce the radiation dose in clinical medical applications.
引用
收藏
页码:2541 / 2559
页数:19
相关论文
共 50 条
  • [21] An image reconstruction algorithm based on the regularized total least squares method for electrical capacitance tomography
    Lei, Jing
    Liu, Shi
    Li, Zhihong
    Schlaberg, H. Inaki
    Sun, Meng
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2008, 19 (06) : 325 - 330
  • [22] Image reconstruction model for the exterior problem of computed tomography based on weighted directional total variation
    Guo, Yumeng
    Zeng, Li
    Wang, Chengxiang
    Zhang, Lingli
    [J]. APPLIED MATHEMATICAL MODELLING, 2017, 52 : 358 - 377
  • [23] FAST HIGH-RESOLUTION IMAGE RECONSTRUCTION USING TIKHONOV REGULARIZATION BASED TOTAL LEAST SQUARES
    Lee, Geunseop
    Fu, Haoying
    Barlow, Jesse L.
    [J]. SIAM JOURNAL ON SCIENTIFIC COMPUTING, 2013, 35 (01): : B275 - B290
  • [24] Non-Local Total Variation based Low-Dose Computed Tomography Denoising
    Hashemi, SayedMasoud
    Beheshti, Soosan
    Cobbold, Richard S. C.
    Paul, Narinder S.
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1083 - 1086
  • [25] A nonlinear total variation based computed tomography (CT) image reconstruction method using gradient reinforcement
    Ertas, Metin
    [J]. PEERJ, 2024, 12
  • [26] Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction
    Liu, Yan
    Ma, Jianhua
    Fan, Yi
    Liang, Zhengrong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (23): : 7923 - 7956
  • [27] Image reconstruction algorithm based on the extended regularised total least squares method for electrical capacitance tomography
    Lei, J.
    Liu, S.
    Li, Z. H.
    Sun, M.
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2008, 2 (05) : 326 - 336
  • [28] Texture-preserved penalized weighted least-squares reconstruction of low-dose CT image via image segmentation and high-order MRF modeling
    Han, Hao
    Zhang, Hao
    Wei, Xinzhou
    Moore, William
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [29] Statistical image reconstruction for low-dose CT using nonlocal means-based regularization
    Zhang, Hao
    Ma, Jianhua
    Wang, Jing
    Liu, Yan
    Lu, Hongbing
    Liang, Zhengrong
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2014, 38 (06) : 423 - 435
  • [30] Deriving adaptive MRF coefficients from previous normal-dose CT scan for low-dose image reconstruction via penalized weighted least-squares minimization
    Zhang, Hao
    Han, Hao
    Wang, Jing
    Ma, Jianhua
    Liu, Yan
    Moore, William
    Liang, Zhengrong
    [J]. MEDICAL PHYSICS, 2014, 41 (04)