PWLS-PR: low-dose computed tomography image reconstruction using a patch-based regularization method based on the penalized weighted least squares total variation approach

被引:5
|
作者
Fu, Jing [1 ,2 ]
Feng, Fei [3 ]
Quan, Huimin [2 ]
Wan, Qian [1 ,4 ]
Chen, Zixiang [1 ]
Liu, Xin [1 ]
Zheng, Hairong [1 ]
Liang, Dong [1 ]
Cheng, Guanxun [3 ]
Hu, Zhanli [1 ]
机构
[1] Chinese Acad Sci, Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Shenzhen, Peoples R China
[2] Hunan Univ, Coll Elect & Informat Engn, Changsha, Peoples R China
[3] Peking Univ Shenzhen Hosp, Dept Radiol, Shenzhen, Peoples R China
[4] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen, Peoples R China
关键词
Lose-dose computed tomography (lose-dose CT); image reconstruction; patch regularization; penalized weighted least squares (PWLS); total variation (TV); LIMITED-ANGLE DATA; NOISE-REDUCTION; ARTIFACT REDUCTION; CT RECONSTRUCTION; SUPERRESOLUTION; MULTISLICE; STRATEGIES; CONTRAST; QUALITY; FILTERS;
D O I
10.21037/qims-20-963
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Radiation exposure computed tomography (CT) scans and the associated risk of cancer in patients have been major clinical concerns. Existing research can achieve low-dose CT imaging by reducing the X-ray current and the number of projections per rotation of the human body. However, this method may produce excessive noise and fringe artifacts in the traditional filtered back projection (FBP)-reconstructed image. Methods: To solve this problem, iterative image reconstruction is a promising option to obtain high-quality images from low-dose scans. This paper proposes a patch-based regularization method based on penalized weighted least squares total variation (PWLS-PR) for iterative image reconstruction. This method uses neighborhood patches instead of single pixels to calculate the nonquadratic penalty. The proposed regularization method is more robust than the conventional regularization method in identifying random fluctuations caused by sharp edges and noise. Each iteration of the proposed algorithm can be described in the following three steps: image updating via the total variation based on penalized weighted least squares (PWLS-TV), image smoothing, and pixel-by-pixel image fusion. Results: Simulation and real-world projection experiments show that the proposed PWLS-PR algorithm achieves a higher image reconstruction performance than similar algorithms. Through the qualitative and quantitative evaluation of simulation experiments, the effectiveness of the method is also verified. Conclusions: Furthermore, this study shows that the PWLS-PR method reduces the amount of projection data required for repeated CT scans and has the useful potential to reduce the radiation dose in clinical medical applications.
引用
收藏
页码:2541 / 2559
页数:19
相关论文
共 50 条
  • [1] Penalized weighted least-squares approach for multienergy computed tomography image reconstruction via structure tensor total variation regularization
    Zeng, Dong
    Gao, Yuanyuan
    Huang, Ling
    Bian, Zhaoying
    Zhang, Hua
    Lu, Lijun
    Ma, Jianhua
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2016, 53 : 19 - 29
  • [2] LBP-based penalized weighted least-squares approach to low-dose cone-beam computed tomography reconstruction
    Ma, Ming
    Wang, Huafeng
    Liu, Yan
    Zhang, Hao
    Gu, Xianfeng
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [3] Total Generalized Variation Constrained Weighted Least-Squares for Low-Dose Computed Tomography Reconstruction
    Niu Shanzhou
    Zhang Mengzhen
    Qiu Yang
    Li Shuo
    Liang Lijing
    Liu Hong
    Liu Guoliang
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (04)
  • [4] Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    Wang, Jing
    Li, Tianfang
    Lu, Hongbing
    Liang, Zhengrong
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (10) : 1272 - 1283
  • [5] Penalized weighted least-squares approach for low-dose X-ray computed tomography
    Wang, Jing
    Li, Tianfang
    Lu, Hongbing
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [6] Effects of the penalty on the penalized weighted least-squares image reconstruction for low-dose CBCT
    Ouyang, Luo
    Solberg, Timothy
    Wang, Jing
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17): : 5535 - 5552
  • [7] Low-dose computed tomography image reconstruction from under-sampling data based on weighted total variation minimization
    Liu, Yan
    Ma, Jianhua
    Fan, Yi
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [8] Penalized Likelihood PET Image Reconstruction Using Patch-Based Edge-Preserving Regularization
    Wang, Guobao
    Qi, Jinyi
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (12) : 2194 - 2204
  • [9] Joint regularization-based image reconstruction by combining data-driven tight frame and total variation for low-dose computed tomography
    Li, Jie
    Zhang, Wenkun
    Cai, Ailong
    Wang, Linyuan
    Liang, Ningning
    Zheng, Zhizhong
    Li, Lei
    Yan, Bin
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (05) : 785 - 803
  • [10] Multiscale penalized weighted least-squares sinogram restoration for low-dose x-ray computed tomography
    Wang, Jing
    Liang, Zhengrong
    Lu, Hongbing
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1666 - +