Adequacy of compression positioning using the feedback device during chest compressions by medical staff in a simulation study

被引:4
|
作者
Koyama, Yasuaki [1 ]
Matsuyama, Tasuku [2 ]
Kaino, Takako [1 ]
Hoshino, Tetsuya [1 ]
Nakao, Junzo [1 ]
Shimojo, Nobutake [1 ]
Inoue, Yoshiaki [1 ]
机构
[1] Univ Tsukuba Hosp, Dept Emergency & Crit Care Med, 2-1-1 Amakubo, Tsukuba, Ibaraki, Japan
[2] Kyoto Prefectural Univ Med, Dept Emergency Med, Kamigyo Ku, 465 Kawaramachi Hirok, Kyoto, Japan
关键词
Chest compressions; Feedback device; Adequate position for chest compressions; Flexible pressure sensor; Hypothenar side; CARDIOPULMONARY-RESUSCITATION; STERNUM FRACTURES; FREQUENCY; HAND; RIB;
D O I
10.1186/s12873-022-00640-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background The 2020 American Heart Association guidelines recommend the use of a feedback device during chest compressions (CCs). However, these devices are only placed visually by medical personnel on the lower half of the sternum and do not provide feedback on the adequacy of the pressure-delivery position. In this study, we investigated whether medical staff could deliver CCs at the adequate compression position using a feedback device and identified where the inadequate position was compressed. Methods This simulation-based, prospective single-centre study enrolled 44 medical personnel who were assigned to four different groups based on the standing position and the hand in contact with the feedback device as follows: right-left (R-l), right-right (R-r), left-right (L-r), and left-left (L-l), respectively. The sensor position where the maximal average pressure was applied during CCs using the feedback device were ascertained with a flexible capacitive pressure sensor. We determined if this position is the adequate compression position or not. The intergroup differences in the frequency of the adequate compression position, the maximal average pressure, compression rate, depth and recoil were determined. Results The frequencies of adequate compression positioning were 55, 50, 58, and 60% in the R-l, R-r, L-r, and L-l groups, respectively, with no significant intergroup difference (p = 0.917). Inadequate position occurred in the front, back, hypothenar and thenar sides. The maximal average pressure did not significantly differ among the groups (p = 0.0781). The average compression rate was 100-110 compressions/min in each group, the average depth was 5-6 cm, and the average recoil was 0.1 cm, with no significant intergroup differences (p = 0.0882, 0.9653, and 0.2757, respectively). Conclusions We found that only approximately half of the medical staff could deliver CCs using the feedback device at an adequate compression position and the inadequate position occurred in all sides. Resuscitation courses should be designed to educate trainees about the proper placement during CCs using a feedback device while also evaluating the correct compression position.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Measuring the effectiveness of a novel CPRcard™ feedback device during simulated chest compressions by non-healthcare workers
    White, Alexander E.
    Ng, Han Xian
    Ng, Wai Yee
    Ng, Eileen Kai Xin
    Fook-Chong, Stephanie
    Kua, Phek Hui Jade
    Ong, Marcus Eng Hock
    SINGAPORE MEDICAL JOURNAL, 2017, 58 (07) : 438 - 445
  • [22] Effect of feedback on delaying deterioration in quality of compressions during 2 minutes of continuous chest compressions: a randomized manikin study investigating performance with and without feedback
    Lyngeraa, Tobias Stenbjerg
    Hjortrup, Peter Buhl
    Wulff, Nille Birk
    Aagaard, Theis
    Lippert, Anne
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2012, 20
  • [23] Effect of feedback on delaying deterioration in quality of compressions during 2 minutes of continuous chest compressions: a randomized manikin study investigating performance with and without feedback
    Tobias Stenbjerg Lyngeraa
    Peter Buhl Hjortrup
    Nille Birk Wulff
    Theis Aagaard
    Anne Lippert
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 20
  • [24] Analysis of chest compression depth and rate during cardiopulmonary resuscitation with and without a feedback device
    Fronczek-Wojciechowska, Magdalena
    Kopacz, Karolina
    Jazwinska, Anna
    Padula, Gianluca
    Gaszynski, Tomasz
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2018, 25 (04) : 179 - 184
  • [25] Comparison of positional shift of supraglottic devices resulting from chest compressions: simulation using a manikin and automated chest compression system
    Kitano, Manabu
    Komasawa, Nobuyasu
    Fujiwara, Shunsuke
    Minami, Toshiaki
    ACUTE MEDICINE & SURGERY, 2015, 2 (02): : 134 - 137
  • [26] A STUDY OF CHEST COMPRESSION RATES DURING CARDIOPULMONARY-RESUSCITATION IN HUMANS - THE IMPORTANCE OF RATE-DIRECTED CHEST COMPRESSIONS
    KERN, KB
    SANDERS, AB
    RAIFE, J
    MILANDER, MM
    OTTO, CW
    EWY, GA
    ARCHIVES OF INTERNAL MEDICINE, 1992, 152 (01) : 145 - 149
  • [27] A randomised control trial of prompt and feedback devices and their impact on quality of chest compressions-A simulation study
    Yeung, Joyce
    Davies, Robin
    Gao, Fang
    Perkins, Gavin D.
    RESUSCITATION, 2014, 85 (04) : 553 - 559
  • [28] Chest compression quality and patient outcomes with the use of a CPR feedback device: A retrospective study
    Wen Zhe Leo
    Damien Chua
    Hui Cheng Tan
    Vui Kian Ho
    Scientific Reports, 13
  • [29] Chest compression quality and patient outcomes with the use of a CPR feedback device: A retrospective study
    Leo, Wen Zhe
    Chua, Damien
    Tan, Hui Cheng
    Ho, Vui Kian
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [30] Effect of Audiovisual Feedback Device Type on Prehospital Chest Compression Quality During Prehospital Resuscitation
    Lee, Stephen Gyung Won G.
    Kim, Tae Han H.
    Song, Kyoung J.
    Park, Jeong Ho
    Kim, Ki Hong
    Choi, Yeongho
    Kim, Minwoo
    Hong, Kijeong
    CIRCULATION, 2023, 148