In vivo measurement of the three-dimensional motion of the sacroiliac joint

被引:20
|
作者
Wilke, HJ [1 ]
Fischer, K [1 ]
Jeanneret, B [1 ]
Claes, L [1 ]
Magerl, F [1 ]
机构
[1] Univ Ulm, Abt Unfallchirurg Forsch & Biomech, D-89081 Ulm, Germany
来源
关键词
sacroiliac joint; biomechanics; low-back pain; in vivo; three-dimensional motion;
D O I
10.1055/s-2008-1039744
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to quantify in vivo the three-dimensional motion patterns of the sacroiliac joint during passive manipulations as the opinions about the extent of motion of this joint are varied. 12 sacroiliac joints of 6 patients with clinically and radiologically normal joints were investigated. All patients were treated with an external fixator for diagnostic purposes of low back pain unrelated to this study. The motion of the sacroiliac joint was measured continuously with a three-dimensional goniometric system, which was mounted at the end of Schanz screws implanted in S1 and the ilium. All measurements showed relatively small rotation angles around the three main axis of the body between the ilium and the sacrum (< 2 degrees) and very small translations between the screw entry points into the bones (<1 mm). The maximum rotation angle in the sagittal plane was 1.3 degrees on the right joint and 1.6 degrees on the left joint for flexion plus extension. It is questionable whether this motion can be quantified during manual manipulation. Extension of the hip always produced the largest motion in the sacroiliac joint.
引用
收藏
页码:550 / 556
页数:7
相关论文
共 50 条
  • [31] Motion Analysis of the Trapeziometacarpal Joint Using Three-dimensional Computed Tomography
    Kimura, Tetsuya
    Takai, Hiroaki
    Azuma, Tatsuo
    Sairyo, Koichi
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (01): : 78 - 84
  • [32] Three-Dimensional Analysis of the In Vivo Motion of Implantable Cardioverter Defibrillator Leads
    Szili-Torok, Tamas
    Rump, Jens
    Luther, Torsten
    Yap, Sing-Chien
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2022, 13 (01) : 129 - 138
  • [33] In Vivo Three-dimensional Motion Analysis of Chronic Radial Head Dislocations
    Miyake, Junichi
    Moritomo, Hisao
    Kataoka, Toshiyuki
    Murase, Tsuyoshi
    Sugamoto, Kazuomi
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (10) : 2746 - 2755
  • [34] The in vivo three-dimensional motion of the human lumbar spine during gait
    Rozumalski, Adam
    Schwartz, Michael H.
    Wervey, Roy
    Swanson, Andrew
    Dykes, Daryll C.
    Novacheck, Tom
    GAIT & POSTURE, 2008, 28 (03) : 378 - 384
  • [35] Three-Dimensional Analysis of the In Vivo Motion of Implantable Cardioverter Defibrillator Leads
    Tamas Szili-Torok
    Jens Rump
    Torsten Luther
    Sing-Chien Yap
    Cardiovascular Engineering and Technology, 2022, 13 : 129 - 138
  • [36] Three-dimensional motion patterns of the carpel bones:: an in vivo study using three-dimensional computed tomography and clinical applications
    Feipel, V
    Rooze, M
    SURGICAL AND RADIOLOGIC ANATOMY, 1999, 21 (02) : 125 - 131
  • [37] Three-dimensional motion patterns of the carpal bones: an in vivo study using three-dimensional computed tomography and clinical applications
    V. Feipel
    M. Rooze
    Surgical and Radiologic Anatomy, 1999, 21 : 125 - 131
  • [38] THREE-DIMENSIONAL MOTION PICTURES
    Norling, J. A.
    JOURNAL OF THE SOCIETY OF MOTION PICTURE ENGINEERS, 1939, 33 (06): : 612 - 634
  • [39] Human scratching motion analysis method by using three-dimensional motion measurement system
    Watanabe, Keisuke
    Abe, Takao
    Isozaki, Goushiro
    Okuyama, Takeshi
    Tanaka, Mami
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2019, 59 (03) : 1111 - 1118
  • [40] Uncertainty Analysis of Spherical Joint Three-Dimensional Rotation Angle Measurement
    Zhang, Jin
    Yang, Qianyun
    Yang, Long
    Hu, Penghao
    APPLIED SCIENCES-BASEL, 2023, 13 (06):