Facile LC-UV methods for simultaneous monitoring of ciprofloxacin and rosuvastatin in API, formulations and human serum

被引:4
|
作者
Arayne, M. Saeed [1 ]
Sultana, Najma [2 ]
Tabassum, Arman [1 ]
机构
[1] Univ Karachi, Dept Chem, Karachi 75270, Pakistan
[2] Univ Karachi, Fac Pharm, Pharmaceut Sci Res Inst, Karachi 75270, Pakistan
关键词
rosuvastatin; ciprofloxacin; liquid chromatography; PHARMACEUTICAL DOSAGE FORMULATIONS; RP-HPLC; VALIDATED METHOD; SIMVASTATIN; LEVOFLOXACIN; GEMIFLOXACIN; ANTIBIOTICS; PRAVASTATIN; CAPTOPRIL; BULK;
D O I
10.1002/bmc.3260
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An efficient, selective and cost-effective liquid chromatographic assay was developed and validated for the simultaneous quantification of ciprofloxacin and rosuvastatin in Active Pharmaceutical Ingredients (API), pharmaceutical formulations and in human serum. The chromatographic system consisted of mobile phase methanol-water, 90:10v/v at pH3.0 adjusted with o-phosphoric acid, pumped at 1.0mL/min through a prepacked Purospher Star C18 (5 mu m, 25x0.46cm) column and effluent was monitored at the isosbestic point (255nm) as well as at the (max) of individual drugs (243 and 271nm). The method was validated over a linear concentration range of 0.25-15 mu g/mL for ciprofloxacin and 0.33-20 mu g/mL for rosuvastatin (r(2)0.999). The ranges of reliable response (limits of detection and quantitation) for ciprofloxacin were 3-15 and 9-45ng/mL and 17-29 and 52-88ng/mL, respectively, for rosuvastatin in all API, pharmaceutical formulations and human serum. Analytical recovery from human serum was >98% and relative standard deviation (RSD) was <2. The accuracies were 97.13-102.55 and 97.41-101.31% and precisions in RSD were 0.04-1.90 and 0.02-1.23% for ciprofloxacin and rosuvastatin, respectively. No matrix interferences, ion suppression/enhancement and carry-over were detected. The total assay run time was less than 5min. In another study, for optimum performance the detector was programmed for multiwavelength scanning at the absorption maxima of each component. Consequently, the linearity range was improved and limit of detection and quantitation values were down to 1-4 and 4-12ng/mL for ciprofloxacin and 3-5 and 9-15ng/mL for rosuvastatin, respectively. The validation parameters fitted ICH guidelines through the isosbestic and individual (max) approach. The small sample volume and simplicity of preparation make this method suitable for use in human serum samples, pharmaceutical formulations, quality control, drug-drug interaction studies, clinical laboratories, drug research centers and forensic medical centers. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:202 / 209
页数:8
相关论文
共 38 条
  • [21] RP-LC Simultaneous Analysis of Ranitidine and NSAIDS in Active Pharmaceutical Ingredient, Formulations and Human Serum
    Naveed, Safila
    Zafar, Farya
    Ali, Huma
    Dilshad, Huma
    Qamar, Fatima
    Abbas, Syeda S.
    Waheed, Nimra
    Nazeer, Safeena
    Ashraf, Zehra
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (07): : 1432 - 1437
  • [22] Simultaneous Determination of Tranexamic Acid and Losartan Potassium in Dosage Formulations and Human Serum by RP-LC
    M. Saeed Arayne
    Najma Sultana
    Faiza Qureshi
    Farhan Ahmed Siddiqui
    Agha Zeeshan Mirza
    Saima Sher Bahadur
    Muhammad Hashim Zuberi
    Chromatographia, 2009, 70 : 789 - 795
  • [23] HPLC-UV method for simultaneous determination of irbesartan, candesartan, gliquidone and pioglitazone in formulations and in human serum
    Agha Zeeshan Mirza
    Journal of Chinese Pharmaceutical Sciences, 2018, 27 (04) : 273 - 280
  • [24] Simultaneous determination of lisinopril and H2 antagonists in API, formulations and human serum by using two different HPLC systems
    Safila Naveed
    Najma Sultana
    M. Saeed Arayne
    Medicinal Chemistry Research, 2012, 21 : 4037 - 4042
  • [25] Simultaneous determination of lisinopril and H2 antagonists in API, formulations and human serum by using two different HPLC systems
    Naveed, Safila
    Sultana, Najma
    Arayne, M. Saeed
    MEDICINAL CHEMISTRY RESEARCH, 2012, 21 (12) : 4037 - 4042
  • [26] Simultaneous Determination of Metformin, Cimetidine, Famotidine, and Ranitidine in Human Serum and Dosage Formulations Using HPLC with UV Detection
    Arayne, M. Saeed
    Sultana, Najma
    Zuberi, M. Hashim
    Siddiqui, Farhan Ahmed
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2010, 48 (09) : 721 - 725
  • [27] Development and utilization of a combined LC-UV and LC-MS/MS method for the simultaneous analysis of tegafur and 5-fluorouracil in human plasma to support a phase I clinical study of oral UFT®/leucovorin
    Peer, Cody J.
    McManus, Terence J.
    Hurwitz, Herbert I.
    Petros, William P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 898 : 32 - 37
  • [28] Simultaneous RP-LC Analysis of Diltiazem and Non-Steroidal Anti-Inflammatory Drugs in Pharmaceutical Formulations and Human Serum
    Najma Sultana
    M. Saeed Arayne
    Nighat Shafi
    Farhan A. Siddiqui
    Chromatographia, 2010, 71 : 71 - 77
  • [29] Simultaneous RP-LC Analysis of Diltiazem and Non-Steroidal Anti-Inflammatory Drugs in Pharmaceutical Formulations and Human Serum
    Sultana, Najma
    Arayne, M. Saeed
    Shafi, Nighat
    Siddiqui, Farhan A.
    CHROMATOGRAPHIA, 2010, 71 (1-2) : 71 - 77
  • [30] Simultaneous LC–UV–MS–MS Analysis of Nine Pivotal Metabolites in Human Serum: Application to Studies of Impaired Glucose Tolerance
    Hongfu Zhong
    Qionglin Liang
    Jianfei Xia
    Ping Hu
    Yiming Wang
    Xiaolin Tong
    Guoan Luo
    Chromatographia, 2011, 73 : 149 - 155