Deformation analysis of in-vivo implant for total hip arthroplasty using multidetector-row CT images

被引:0
|
作者
Kobashi, S. [1 ]
Shibanuma, N. [2 ]
Kondo, K. [1 ]
Kurosaka, M. [2 ]
Hata, Y. [1 ]
机构
[1] Univ Hyogo, Grad Sch Engn, 2167 Shosha, Himeji, Hyogo 6712280, Japan
[2] Kobe Univ, Grad Sch Med, Himeji, Hyogo 6712280, Japan
来源
NAFIPS 2006 - 2006 ANNUAL MEETING OF THE NORTH AMERICAN FUZZY INFORMATION PROCESSING SOCIETY, VOLS 1 AND 2 | 2006年
关键词
D O I
10.1109/NAFIPS.2006.365472
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In the field of orthopedic surgery, many types of implant have been used. Especially, revision total hip arthroplasty (THA) uses a metallic implant called support implant to reconstruct the damaged acetabulum. After the revision THA, the support implant might be deformed or be broken in serious cases by the strong load or by the other factors. However, there are few effective diagnosing methods for evaluating the 3-D deformation of the support implant in vivo. This study proposes a novel approach for finding the deformation of the support implant in vivo. The proposed method uses Multidetector-row CT images to take the 3-D shape of the support implant, and employs the combination of finite element method (FEM) and genetic algorithm (GA). The new combination gives us the new application of FEM. The proposed system was evaluated by computer-simulation experiment, and the effective of the system was demonstrated by applying it to the revision THA patient.
引用
收藏
页码:570 / +
页数:2
相关论文
共 50 条
  • [21] Pancreatic ductal adenocarcinoma: Usefulness of iisotropic multiplanar reformation images obtained with multidetector-row CT
    Sou, H
    Ichikawa, T
    Nakajima, H
    Kitamura, T
    Tsukamoto, T
    Araki, T
    RADIOLOGY, 2002, 225 : 302 - 302
  • [22] CT urography: Description of a novel technique using a uniquely modified multidetector-row CT scanner
    Vrtiska, TJ
    King, BF
    LeRoy, AJ
    Hattery, RR
    McCollough, CH
    Quam, JP
    RADIOLOGY, 2000, 217 : 225 - 225
  • [23] Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT: correlation with histopathological findings
    Takeyuki Watadani
    Masaaki Akahane
    Takeharu Yoshikawa
    Kuni Ohtomo
    Radiation Medicine, 2008, 26 : 402 - 407
  • [24] A case of transdiaphragmatic intercostal hernia: the efficacy of using multidetector-row CT with multiplanar reformation
    Yanagawa, Y.
    Kaneko, N.
    EMERGENCY MEDICINE JOURNAL, 2011, 28 (01) : 10 - 10
  • [25] Using Multidetector-Row CT for the Diagnosis of Afferent Loop Syndrome Following Gastroenterostomy Reconstruction
    Juan, Yu-Hsiu
    Yu, Chih-Yung
    Hsu, Hsian-He
    Huang, Guo-Shu
    Chan, De-Chuan
    Liu, Chang-Hsien
    Tung, Ho-Jui
    Chang, Wei-Chou
    YONSEI MEDICAL JOURNAL, 2011, 52 (04) : 574 - 580
  • [26] Prevalence of Temporal Bone Fractures in Patients with Mandibular Fractures Using Multidetector-Row CT
    I. Ogura
    T. Kaneda
    Y. Sasaki
    K. Buch
    O. Sakai
    Clinical Neuroradiology, 2015, 25 : 137 - 141
  • [27] Evaluation of coronary artery bypass grafts using multidetector-row CT with Japanese patients
    Murai S.
    Hamada S.
    Yamamoto S.
    Khankan A.A.
    Sumikawa H.
    Inoue A.
    Tsubamoto M.
    Honda O.
    Tomiyama N.
    Johkoh T.
    Nakamura H.
    Radiation Medicine, 2006, 24 (1): : 72 - 76
  • [28] The value of drip infusion cholangiography using multidetector-row helical CT in patients with choledocholithiasis
    Okada, M
    Fukada, J
    Toya, K
    Ito, R
    Ohashi, T
    Yorozu, A
    EUROPEAN RADIOLOGY, 2005, 15 (10) : 2140 - 2145
  • [29] Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT: correlation with histopathological findings
    Watadani, Takeyuki
    Akahane, Masaaki
    Yoshikawa, Takeharu
    Ohtomo, Kuni
    RADIATION MEDICINE, 2008, 26 (07): : 402 - 407
  • [30] The value of drip infusion cholangiography using multidetector-row helical CT in patients with choledocholithiasis
    Masahiro Okada
    Jun-ichi Fukada
    Kazuhito Toya
    Reiko Ito
    Toshio Ohashi
    Atsunori Yorozu
    European Radiology, 2005, 15 : 2140 - 2145