Differences in the Corneal Biomechanical Changes After SMILE and LASIK

被引:85
|
作者
Wang, Danyang [1 ]
Liu, Manli [1 ]
Chen, Yile [1 ]
Zhang, Xiaoying [1 ]
Xu, Yangtao [2 ]
Wang, Jianchao [3 ]
To, Chi-ho [1 ,4 ]
Liu, Quan [1 ,4 ]
机构
[1] Sun Yat Sen Univ, State Key Lab Ophthalmol, Zhongshan Ophthalm Ctr, Guangzhou 510275, Guangdong, Peoples R China
[2] Liu Zhou Workers Hosp, Dept Ophthalmol, Liu Zhou, Guang Xi, Peoples R China
[3] Xi An Jiao Tong Univ, Coll Med, Affiliated Hosp 2, Dept Ophthalmol, Xian 710049, Shan Xi, Peoples R China
[4] Hong Kong Polytech Univ, Sch Optometry, Ctr Myopia Res, Lab Expt Optometry, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
INCISION LENTICULE EXTRACTION; OCULAR RESPONSE ANALYZER; IN-SITU KERATOMILEUSIS; THICKNESS MEASUREMENT; LASER; REPRODUCIBILITY; REPEATABILITY; HYSTERESIS; PARAMETERS; MYOPIA;
D O I
10.3928/1081597X-20140903-09
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the corneal biomechanical properties before and after small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK in different levels of myopia with the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Depew, NY). METHODS: A total of 187 and 79 eyes that received SMILE or LASIK, respectively, between January and June 2013 at Zhongshan Ophthalmic Center were enrolled in this study. Patients were grouped according to surgery type (SMILE or LASIK) and -6.00 diopters (D) or less (< -6.00 D) or myopia greater than -6.00 D (> -6.00 D). Corneal hysteresis, corneal resistance factor, and 37 waveform parameters were recorded and compared preoperatively and at 1 week and 1 and 3 months postoperatively. RESULTS: There was a significant decrease of corneal hysteresis, corneal resistance factor, p1area, and p2area, and an increase of path1 and path2 in both SMILE and LASIK. In myopia -6.00 D or less, the differences between SMILE and LASIK were not significant (P > .05), but in myopia greater than-6.00 D, the corneal hysteresis, corneal resistance factor, p1area, and p2area decreased significantly more in LASIK than in SMILE (P < .05). CONCLUSIONS: When comparing SMILE with LASIK, myopia was greater than -6.00 D, and the corneal hysteresis, corneal resistance factor, p1area, and p2area decrease was less after SMILE.
引用
收藏
页码:702 / U57
页数:7
相关论文
共 50 条
  • [1] Corneal Biomechanical Changes and Tissue Remodeling After SMILE and LASIK
    Shetty, Rohit
    Francis, Mathew
    Shroff, Rushad
    Pahuja, Natasha
    Khamar, Pooja
    Girrish, Molleti
    Nuijts, Rudy M. M. A.
    Roy, Abhijit Sinha
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (13) : 5695 - 5704
  • [2] Comparison of corneal biomechanical changes after LASIK and F-SMILE with CorVis ST
    Abd El-Fattah, Eman A.
    El Dorghamy, Alaa A.
    Ghoneim, Ahmed M.
    Saad, Hisham A.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (04) : 1762 - 1770
  • [3] A comparison of biomechanical changes after PRK, LASIK and SMILE
    Wilson, Abby
    Archer, Timothy J.
    Reinstein, Dan Z.
    Marshall, John
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [4] Corneal Denervation After SMILE Versus LASIK
    Teus, Miguel A.
    Garcia-Gonzalez, Montserrat
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (07) : 504 - 504
  • [5] Comparison of changes in corneal volume and corneal thickness after myopia correction between LASIK and SMILE
    Schuh, Anna
    Kolb, Carolin M.
    Mayer, Wolfgang J.
    Vounotrypidis, Efstathios
    Kreutzer, Thomas
    Kohnen, Thomas
    Priglinger, Siegfried
    Shajari, Mehdi
    Kook, Daniel
    [J]. PLOS ONE, 2021, 16 (05):
  • [6] Intraocular Pressure Changes and Relationship With Corneal Biomechanics After SMILE and FS-LASIK
    Li, Hua
    Wang, Yan
    Dou, Rui
    Wei, Pinghui
    Zhang, Jiamei
    Zhao, Wei
    Li, Liuyang
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (10) : 4180 - 4186
  • [7] Review of Corneal Biomechanical Properties Following LASIK and SMILE for Myopia and Myopic Astigmatism
    Damgaard, Iben Bach
    Reffat, Mohamed
    Hjortdal, Jesper
    [J]. OPEN OPHTHALMOLOGY JOURNAL, 2018, 12 : 164 - 174
  • [8] The Study on Changes of Rabbit Corneal Biomechanical Properties after Femtosecond Assisted LASIK
    Khan, Muhammad Ahmad
    Lin, Ding
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [9] Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry
    Iben Bach Pedersen
    Sashia Bak-Nielsen
    Anders Højslet Vestergaard
    Anders Ivarsen
    Jesper Hjortdal
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1329 - 1335
  • [10] Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry
    Pedersen, Iben Bach
    Bak-Nielsen, Sashia
    Vestergaard, Anders Hojslet
    Ivarsen, Anders
    Hjortdal, Jesper
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (08) : 1329 - 1335