The Development and Application of a Novel Apparatus for the Freezing Point Test of Soil

被引:0
|
作者
Zhou, Yongyi [1 ]
Zhang, Jianjing [1 ]
Xie, Qiang [1 ]
Yan, Shijie [1 ]
Niu, Jiayong [1 ]
机构
[1] Southwest Jiaotong Univ, Dept Civil Engn, 111,North 1st Sect Second Ring Rd, Chengdu 610031, Sichuan, Peoples R China
来源
GEOTECHNICAL TESTING JOURNAL | 2022年 / 45卷 / 03期
基金
国家重点研发计划;
关键词
freezing point; supercooling; hypercooling; SN-PID; solid-state cooling; THERMOELECTRIC COOLER; DEPRESSION; CURVES; FROZEN;
D O I
10.1520/GTJ20210002
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The nonuniform freezing of the sample has a considerable influence on the result of the freezing point test. It is associated with the size of samples and called the "size effect." A novel apparatus based on solid-state cooling technology was developed to solve this problem. A linear freezing mode called the "ramped freezing" (RF) was proposed to replace the "constant freezing" (CF) and provide a uniform freezing condition for the soil sample. The single neuron network was used to dynamically optimize the parameters of the Proportional-IntegralDerivative algorithm and improve the performance of variable temperature control. Freezing tests of water solutions were designed to verify the applicability of this apparatus. Key parameters, such as the freezing point (Tf) and the supercooling point (Ts), could be reflected in the cooling curves. Then, freezing point tests of soils with different freezing modes were carried out. Under the CF condition, the soil sample partly freezes from the surface to the central point. Because the temperature monitored by the sensor is the average value of the sensor-soil interface, the "apparent freezing point" obtained from the sample with CF mode is higher than the actual freezing point. For the sample with RF mode, the latent heat cannot raise the sample temperature to the equilibrium freezing point if the pore water is "hypercooled." The freezing point will be underestimated in this condition. Two measures, applying an external disturbance on the test box and turning up the set temperature after the release of latent heat, can be adopted to avoid the influence of hypercooling.
引用
收藏
页码:644 / 660
页数:17
相关论文
共 50 条
  • [21] Soil freezing point as obtained on melting
    Kozlowski, T
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2004, 38 (2-3) : 93 - 101
  • [22] Development and application of new apparatus for K-0 test
    Zhu Jun-gao
    Lu Yang-yang
    Jiang Ming-jie
    Chu Fu-yong
    ROCK AND SOIL MECHANICS, 2018, 39 (08) : 3071 - 3076
  • [23] Development of a novel plane strain test apparatus for frozen soils
    Yao, Xiaoliang
    Zhang, Mingyi
    Xu, Guofang
    Yu, Fan
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2018, 155 : 252 - 262
  • [24] A DIFFERENTIAL HEAT-LOSS FREEZING-POINT APPARATUS
    BERNSTEIN, IM
    JOURNAL OF PHYSICAL AND COLLOID CHEMISTRY, 1951, 55 (07): : 1231 - 1239
  • [25] Development and application of simulation test apparatus for gassy coal dynamic failure
    Yuan, Rui-Fu
    Li, Huai-Zhen
    Meitan Xuebao/Journal of the China Coal Society, 2013, 38 (SUPPL.1): : 117 - 123
  • [26] Low freezing point of inert liquid test and analysis based on the frozen soil moisture research
    Gao, Yu
    Shang, Yunhu
    Dai, Chang-lei
    Liu, Yue
    Wu, Gen-zhi
    ADVANCES IN ENERGY SCIENCE AND EQUIPMENT ENGINEERING, 2015, : 1209 - 1214
  • [27] Application Development of Smoke Leakage Test Apparatus for Door Sets in the Field
    Hung, Hsuan-Yu
    Lin, Ching-Yuan
    Chuang, Ying-Ji
    Luan, Chung-Pi
    FIRE-SWITZERLAND, 2022, 5 (01):
  • [28] Laboratory investigation of the freezing point of saline soil
    Bing, Hui
    Ma, Wei
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2011, 67 (1-2) : 79 - 88
  • [29] FREEZING-POINT TEST OF COW MILK
    DILLIERZULAUF, A
    ALIMENTA, 1984, 23 (05): : 139 - 143
  • [30] NEW TYPE OF FREEZING-POINT APPARATUS - FREEZING POINTS OF DILUTE LANTHANUM CHLORIDE SOLUTIONS
    SCATCHARD, G
    VONNEGUT, B
    BEAUMONT, DW
    JOURNAL OF CHEMICAL PHYSICS, 1960, 33 (05): : 1292 - 1298