A Flexible Calibration Approach for Cameras with Double-sided Telecentric Lenses

被引:30
|
作者
Yao, Linshen [1 ,2 ]
Liu, Haibo [1 ,2 ]
机构
[1] Natl Univ Def Technol, Coll Aerosp Sci & Engn, Changsha, Hunan, Peoples R China
[2] Hunan Prov Key Lab Image Measurement & Vis Nav, Changsha, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Camera Calibration; Double-sided Telecentric Lens; Parallel Projection; Distortion; Homographic Matrix; ACCURACY; SYSTEM;
D O I
10.5772/63825
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
With their constant perspective and large magnification in the working distance, double-sided telecentric lenses have been widely used in machine-vision applications. This paper puts forward a flexible calibration approach for the double-sided telecentric camera. Based on an orthographic projection model considering the major sources of lens distortions, a two-step calibration procedure is proposed. In this approach, the camera parameters apart from the lens distortions are achieved by a closed-form solution. Then a double non-linear optimization is performed to refine all the parameters, including the distortion coefficients and distortion centre. In addition, to achieve a flexible calibration procedure, the calibration pattern used is a cheap print product rather than a professional customized calibration pattern. Simulation and real-world experiments are performed to validate the performance of the proposed calibration approach. In addition, the comparison experiments between the print calibration pattern and professional calibration pattern are carried out, and the accuracy of calibration results are at the same level.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A Camera Model for Line-Scan Cameras with Telecentric Lenses
    Carsten Steger
    Markus Ulrich
    International Journal of Computer Vision, 2021, 129 : 80 - 99
  • [22] A Camera Model for Line-Scan Cameras with Telecentric Lenses
    Steger, Carsten
    Ulrich, Markus
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 2021, 129 (01) : 80 - 99
  • [23] Development, manufacturing and application of double-sided flexible implantable microelectrodes
    Wigand Poppendieck
    Adam Sossalla
    Marc-Oliver Krob
    Christine Welsch
    T. A. Khoa Nguyen
    Wangsong Gong
    Jack DiGiovanna
    Silvestro Micera
    Daniel M. Merfeld
    Klaus-Peter Hoffmann
    Biomedical Microdevices, 2014, 16 : 837 - 850
  • [24] Development, manufacturing and application of double-sided flexible implantable microelectrodes
    Poppendieck, Wigand
    Sossalla, Adam
    Krob, Marc-Oliver
    Welsch, Christine
    Nguyen, T. A. Khoa
    Gong, Wangsong
    DiGiovanna, Jack
    Micera, Silvestro
    Merfeld, Daniel M.
    Hoffmann, Klaus-Peter
    BIOMEDICAL MICRODEVICES, 2014, 16 (06) : 837 - 850
  • [25] CALIBRATION OF LENSES AND CAMERAS AT USGS
    TAYMAN, WP
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1974, 40 (11): : 1331 - 1334
  • [26] Automatically retrieving an initial design of a double-sided telecentric zoom lens based on a particle swarm optimization
    Fan, Zichao
    Wei, Shili
    Zhu, Zhengbo
    Mo, Yan
    Yan, Yiming
    Ma, Donglin
    APPLIED OPTICS, 2019, 58 (27) : 7379 - 7386
  • [27] DOUBLE-SIDED DEWATERING
    WIGHTMAN, WS
    TAPPI, 1977, 60 (01): : 150 - 151
  • [28] DOUBLE-SIDED PHOTOLITHOGRAPHY
    HEINZ, RA
    CHUSS, JT
    SCHROEDER, CM
    SOLID STATE TECHNOLOGY, 1978, 21 (08) : 55 - 60
  • [29] What and who with: A social approach to double-sided recommendation
    Lombardi, Ilaria
    Vernero, Fabiana
    INTERNATIONAL JOURNAL OF HUMAN-COMPUTER STUDIES, 2017, 101 : 62 - 75
  • [30] Optical system design of double-sided telecentric microscope with high numerical aperture and long working distance
    Zhang, Kun
    Li, Jingchen
    Sun, Si
    Wang, Jian
    Yu, Siyang
    OPTICS EXPRESS, 2023, 31 (14) : 23518 - 23532