Determination of shear strength of brick-mortar bed joint is critical to overcome the sliding-shear or joint-shear failure in masonry. In the recent past, researchers have attempted to enhance the shear strength and deformation capacity of brick-mortar bed joints by gluing fiber-reinforced polymer (FRP) composite across the bed joint. FRP composites offer several advantages like high strength-to-weight ratio, and ease of application in terms of labor, time, and reduced curing period. Furthermore, FRP composites are desirable for strengthening old masonry buildings having heritage value because of its minimal interference with the existing architecture. A majority of earlier studies on shear strengthening of masonry available in the literature adopted masonry having the ratio of modulus of elasticity of masonry unit (Emu) to modulus of elasticity of mortar (Em) greater than one. Information related to shear behavior of FRP glued masonry composed of masonry units having Young's modulus lower than mortar is limited. Hence the present study is focused on characterizing the interfacial behavior of brick-mortar bed joint of masonry assemblages composed of solid burnt clay bricks and cement-sand mortar (E-mu/E-m ratio less than one), strengthened with FRP composites. Masonry triplets and prisms with bed joint inclined to loading axis (0 degrees, 30 degrees, 45 degrees, 60 degrees and 90 degrees) are employed in this study. Glass and carbon FRP composites composed of bidirectional FRP fabric with equal density in both directions are used for strengthening masonry. Masonry triplets are glued with glass and carbon FRP composites in two configurations: (1) both faces of the triplet specimens are fully glued with GFRP composites; and (2) both faces of the triplet specimens are glued with GFRP and CFRP composites in strip form. The performance of masonry assemblages strengthened with FRP composites is assessed in terms of gain in shear strength, shear displacement, and postpeak behavior for various configurations and types of FRP composites considered. A semianalytical model is proposed for the prediction of shear strength of masonry bed joints glued with FRP composites. A composite failure envelope consisting of a Coulomb friction model and a compression cap is obtained for unreinforced masonry and GFRP-strengthened masonry based on the test results of masonry triplets and masonry prisms with bed joints having various inclinations to the loading (C) 2015 American Society of Civil Engineers.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] The Bond-Slip Relationship at FRP-to-Brick Interfaces under Dynamic Loading
    Zhang, Di
    Yang, Jun
    Chi, Li Yuan
    MATERIALS, 2021, 14 (03) : 1 - 24
  • [22] Buckling behavior of strengthened perforated plates under shear loading
    Department of Civil Engineering, Shanghai Jiao Tong University, Shanghai, China
    Steel Compos. Struct., 2012, 4 (367-382):
  • [23] Buckling behavior of strengthened perforated plates under shear loading
    Cheng, Bin
    Li, Chun
    STEEL AND COMPOSITE STRUCTURES, 2012, 13 (04): : 367 - 382
  • [24] Acoustic emission monitoring and damage assessment of FRP-strengthened reinforced concrete columns under cyclic loading
    Ma, Gao
    Li, Hui
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 144 : 86 - 98
  • [25] Behavior of FRP strengthened infill walls under in-plane seismic loading
    Almusallam, Tarek H.
    Al-Salloum, Yousef A.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2007, 11 (03) : 308 - 318
  • [26] Nonlinear Finite Element Analyses of FRP-Strengthened Concrete Slabs under Fixed-Point Cyclic Loading
    Teng, Xiaodan
    Zhang, Y. X.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (03)
  • [27] Numerical analysis of the load-bearing capacity of brick masonry walls strengthened with textile reinforced mortar and subjected to eccentric compressive loading
    Bernat-Maso, Ernest
    Gil, Lluis
    Roca, Pere
    ENGINEERING STRUCTURES, 2015, 91 : 96 - 111
  • [28] Interfacial Shear Stresses Calculation of RC Beams Strengthened with FRP Plate under Symmetry Concentrated Loading
    Yang, Jia
    Wang, Lianguang
    Zhang, Ni
    APPLIED MECHANICS AND MATERIALS II, PTS 1 AND 2, 2014, 477-478 : 773 - 776
  • [29] PARTLY UNBONDED INTERFACES BETWEEN DISSIMILAR MATERIALS UNDER NORMAL AND SHEAR LOADING
    THEOCARIS, PS
    ACTA MECHANICA, 1976, 24 (1-2) : 99 - 115
  • [30] Punching shear strength considering cumulative damage for FRP strengthened bridge decks under fatigue loading
    Park, Cheolwoo
    Sim, Jongsung
    Lee, Tai Sik
    FRACTURE AND DAMAGE MECHANICS V, PTS 1 AND 2, 2006, 324-325 : 1313 - +