Comparison of comfort between cone beam breast computed tomography and digital mammography

被引:17
|
作者
Li, Haijie [1 ]
Yin, Lu [1 ]
He, Ni [2 ]
Han, Peng [1 ]
Zhu, Yueqiang [1 ]
Ma, Yue [1 ]
Liu, Aidi [1 ]
Lu, Hong [1 ]
Gao, Zhipeng [1 ]
Liu, Peifang [1 ]
Wu, Yaopan [2 ]
Ye, Zhaoxiang [1 ]
机构
[1] Tianjin Med Univ, Key Lab Breast Canc Prevent & Therapy,Minist Educ, Tianjins Clin Res Ctr Canc,Canc Inst & Hosp,Dept, Natl Clin Res Ctr Canc,Key Lab Canc Prevent & The, Tianjin, Peoples R China
[2] Sun Yat Sen Univ, Dept Radiol, Canc Ctr, 651 Dongfeng Rd East, Guangzhou 510060, Guangdong, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Breast neoplasms; Cone-Beam Computed Tomography; Mammography; Pain; PAIN; CT; COMPRESSION; DISCOMFORT; MORTALITY;
D O I
10.1016/j.ejrad.2019.108674
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the comfort levels of cone beam breast computed tomography (CBBCT) and digital mammography. Materials and methods: On 409 patients, CBBCT was performed within 1 week after conventional mammography. Patients evaluated their comfort by using an 11-point numerical rating scale (NRS-11) after completing the two examinations. The lower the score was, the more comfortable the examination modality was. The data was divided into different groups according to CBBCT scan mode (non-contrast mode, contrast-enhanced mode), age (<= 44, 45 similar to 59 and >= 60), body mass index (BMI) (< 18.5 kg/m(2), 18.5 similar to 23.9 kg/m(2), 24 similar to 27.9 kg/m(2) and >= 28 kg/m(2)), and breast density (fatty-breast, dense-breast) to evaluate the performance of CBBCT comfort in different groups and to analyse the influencing factor of patient comfort. The paired rank sum test was used to compare the comfort between CBBCT and mammography. Results: Overall, the comfort of CBBCT was better than mammography (P< 0.05). CBBCT was more comfortable than mammography in both non-contrast and contrast-enhanced groups (P < 0.05). CBBCT was more comfortable than mammography in the <= 44, 45 similar to 59 age groups (P < 0.05). There was no significant difference in the >= 60 age group (P = 0.5433). CBBCT was more comfortable than mammography in the BMI groups of 18.5 similar to 23.9 kg/m(2), 24 similar to 27.9 kg/m(2)and >= 28 kg/m(2) (P < 0.05). There was no significant difference in the< 18.5 kg/m(2) group (P= 0.43). CBBCT was more comfortable than mammography in both the fatty-breast and dense-breast groups (P < 0.05). Conclusion: The comfort of CBBCT was better than mammography.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Comparison of linear and angular changes assessed in digital dental models and cone-beam computed tomography
    Massaro, Camila
    Losada, Carolina
    Cevidanes, Lucia
    Yatabe, Marilia
    Garib, Daniela
    Pereira Lauris, Jose Roberto
    Ioshida, Marcos
    Rey, Diego
    Antonia Alvarez, Maria
    Benavides, Erika
    Rios, Hector
    Fernando Aristizabal, Juan
    Ruellas, Antonio Carlos
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2020, 23 (01) : 118 - 128
  • [32] Comparison of Cone Beam Computed Tomography and Digital Radiography in Detecting Separated Endodontic Files and Strip Perforation
    Abdinian, Mehrdad
    Moshkforoush, Saba
    Hemati, Hamidreza
    Soltani, Parisa
    Moshkforoushan, Mansoure
    Spagnuolo, Gianrico
    APPLIED SCIENCES-BASEL, 2020, 10 (23): : 1 - 11
  • [33] EVALUATION OF DOSE HOMOGENEITY IN CONE-BEAM BREAST COMPUTED TOMOGRAPHY
    Mettivier, Giovanni
    Costa, Matilde
    Lanconelli, Nico
    Ianiro, Anna
    Pugliese, Mariagabriella
    Quarto, Maria
    Russo, Paolo
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (04) : 473 - 481
  • [34] Cone-Beam Computed Tomography for Breast Biopsy Analysis: Simulations
    Laamanen, C.
    LeClair, R.
    MEDICAL PHYSICS, 2012, 39 (07) : 4641 - 4641
  • [35] Evaluation of the relationship between phantom position and computed tomography dose index in cone beam computed tomography when assuming breast irradiation
    Ueno, Hiroyuki
    Matsubara, Kosuke
    Takemura, Akihiro
    Hizume, Masato
    Bou, Sayuri
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 262 - 267
  • [36] Detectability of Multiple Slice Breast Cone Beam Computed Tomography Images
    Han, M.
    Kim, B.
    Baek, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3141 - 3141
  • [37] Comparison between cone-beam and multislice computed tomography for identification of simulated bone lesions
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Perrella, Andreia
    Fenyo-Pereira, Marlene
    Paraiso Cavalcanti, Marcelo Gusmao
    BRAZILIAN ORAL RESEARCH, 2011, 25 (04) : 362 - 368
  • [38] Measuring the alveolar bone level in adolescents: A comparison between ultrasound and cone beam computed tomography
    Nguyen, Kim-Cuong T.
    Le, Lawrence H.
    Kaipatur, Neelambar R.
    Almeida, Fabiana T.
    Lai, Hollis
    Lou, Edmond H. M.
    Major, Paul W.
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2023, 33 (05) : 487 - 497
  • [39] Cone beam computed tomography in endodontics
    Jasem Greval
    British Dental Journal, 2019, 226 (2) : 92 - 92
  • [40] Panoramic cone beam computed tomography
    Chang, Jenghwa
    Zhou, Lili
    Wang, Song
    Chao, K. S. Clifford
    MEDICAL PHYSICS, 2012, 39 (05) : 2930 - 2946