Evaluating Organ Dose and Radiation Risk of Routine CT Examinations in Johor, Malaysia

被引:0
|
作者
Karim, M. K. A. [1 ,2 ]
Hashim, S. [1 ]
Sabarudin, A. [3 ]
Bradley, D. A. [4 ]
Bahruddin, N. A. [1 ]
机构
[1] Univ Teknol Malaysia, Dept Phys, Skudai 81310, Johor Darul Tak, Malaysia
[2] Johor State Hlth Dept, Div Publ Hlth, Johor Baharu 80100, Johor Darul Tak, Malaysia
[3] Univ Kebangsaan Malaysia, Fac Hlth Sci, Jalan Raja Muda Abdul Aziz, Kuala Lumpur 50300, Malaysia
[4] Univ Surrey, Dept Phys, Ctr Nucl & Radiat Phys, Guildford GU2 7XH, Surrey, England
来源
SAINS MALAYSIANA | 2016年 / 45卷 / 04期
关键词
CT scan; effective dose; organ equivalent dose; risk assessment; DIAGNOSTIC REFERENCE LEVELS; COMPUTED-TOMOGRAPHY; PROTECTION; HOSPITALS; EXPOSURE;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this study, radiation doses from CT scan procedures and its related risks to the patients from five hospitals in Johor State, Malaysia were analyzed. The survey was conducted in a two-month period encompassing data for 460 patients with the number for each hospital being set at 32, 30 and 30 samples for CT brain, CT thorax and CT abdomen, respectively. The results indicated that the CTDIw, DLP and effective dose values ranged from 7.0 +/- 1.3 to 67.7 +/- 3.4 mGy, 300.2 +/- 135.4 to 1174.2 +/- 79.9 mGy. cm and 1.5 +/- 0.2 to 11.7 +/- 6.65 mSv, respectively. The organ doses were calculated using CT EXPO software (Ver. 2.3.1, Germany) and were found to vary within the hospitals and the type of the CT examinations. Effective cancer risks per procedure were calculated by multiplying organ dose with the nominal cancer risk that was adapted from International Commission on Radiological Protection (ICRP) Publication 103. The values ranged from 0 to 1449 cancer cases per one million procedures for these three routine examinations. This present work showed that the CT systems can impart high radiation doses and increase of radiation risk to patients if optimization protocols are ignored.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 50 条
  • [1] Evaluation of radiation dose and radiation-induced cancer risk associated with routine CT scan examinations
    Bagherzadeh, Saeed
    Mirderikvand, Afsaneh
    Mohammadsharifi, Ali
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2024, 217
  • [2] Evaluation of patient radiation dose and risk of cancer from CT examinations
    Poosiri, Saowapark
    Krisanachinda, Anchali
    Khamwan, Kitiwat
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 176 - 185
  • [3] Evaluation of patient radiation dose and risk of cancer from CT examinations
    Saowapark Poosiri
    Anchali Krisanachinda
    Kitiwat Khamwan
    [J]. Radiological Physics and Technology, 2024, 17 : 176 - 185
  • [4] Radiation dose and risk to the lens of the eye during CT examinations of the brain
    Poon, Rebekah
    Badawy, Mohamed K.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2019, 63 (06) : 786 - 794
  • [5] Organ Doses, Effective Dose, and Cancer Risk From Coronary CT Angiography Examinations
    Mahmoodi, Maede
    Chaparian, Ali
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (05) : 1131 - 1136
  • [6] CT EXAMINATIONS WITH REDUCED RADIATION-DOSE
    FELSENBERG, D
    KALENDER, WA
    TRINKWALTER, W
    WOLF, KJ
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 153 (05): : 516 - 521
  • [7] Tracking radiation dose for PET/CT examinations
    Imran, Rebecca
    Moreno, Roberto Maass
    Chen, Clara
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [8] Breast radiation dose equivalent and cancer risk estimation during PET/ CT examinations
    Jambi, Layal
    Alkhorayef, Mohammed
    Almuwanis, Mohammed
    Sulieman, Abdelmoneim
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [9] Automated Extraction of Radiation Dose Information for CT Examinations
    Cook, Tessa S.
    Zimmerman, Stefan
    Maidment, Andrew D. A.
    Kim, Woojin
    Boonn, William W.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2010, 7 (11) : 871 - 877
  • [10] Radiation dose and image quality in head CT examinations
    Huda, W
    Chang, J
    Lieberman, KA
    Roskopf, ML
    [J]. RADIOLOGY, 2001, 221 : 160 - 160