Influence of superstructure materials on strain around an implant under 2 loading conditions: A technical investigation

被引:0
|
作者
Stegaroiu, R
Khraisat, A
Nomura, S
Miyakawa, O
机构
[1] Niigata Univ, Grad Sch Med & Dent Sci, Dept Oral Hlth Sci, Div Oral Hlth Aging & Fixed Prosthodont, Niigata 9518514, Japan
[2] Univ Jordan, Fac Dent, Dept Conservat Dent & Prosthodont, Amman, Jordan
[3] Niigata Univ, Grad Sch Med & Dent Sci, Dept Oral Hlth Sci, Div Dent Biomat Sci, Niigata 9518514, Japan
关键词
dental implants; dental materials; dynamic loading; static loading; strain gauges;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This investigation was concerned with the effect of 3 superstructure materials on the strain around an implant under static and nonimpact dynamic loading. Materials and Methods: Five highly filled composite resin-veneered crown analogs, 5 autopolymerized acrylic resin-veneered crown analogs, and 5 gold-alloy full cast crown analogs were prepared. The resin veneers were applied to gold-alloy frameworks. These crown analogs were prepared to fit an ITI implant-abutment assembly, which was screwed into a block of acrylic resin to simulate implantation in bone. The crown analogs were successively placed on the abutment, and a lateral load of 100 N was applied to the superstructure by a lever-type testing machine. Strains were recorded under static and dynamic loading by a 2-mm-long strain gauge bonded to the surface of the bone simulant tangential to the implant. The dynamic load simulated masticatory cycles (75 strokes/min). Results: Although the strain values differed significantly between the static and dynamic loading (P < .05), there was no significant difference among the superstructure materials under either loading condition (P > .05). Discussion: These findings are in agreement with in vivo measurements, thus suggesting that cyclic rather than impact loading should be used in the investigation of occlusal material behavior under functional loading. Conclusion: Under static and nonimpact dynamic loading, the 3 superstructure materials tested (highly filled composite resin, acrylic resin, and gold alloy) had the same influence on the strain transmitted to a bone simulant that surrounded a single implant.
引用
收藏
页码:735 / 742
页数:8
相关论文
共 50 条
  • [21] Investigation of the influence of the loading direction on the strength of composite materials
    Skvortsov, Yu. V.
    Evtushenko, M. A.
    Manukyan, L. A.
    INTERNATIONAL JOURNAL OF MODELING SIMULATION AND SCIENTIFIC COMPUTING, 2025, 16 (01)
  • [22] Influence of Implant Number and Location on Strain Around an Implant Combined with Force Transferred to the Palate in Maxillary Overdentures
    Yang, Tsung-Chieh
    Chen, Yi-Chen
    Wang, Tong-Mei
    Lin, Li-Deh
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (03) : 286 - 288
  • [24] CHARACTERIZATION OF ADHESIVE MATERIALS UNDER HIGH STRAIN RATE LOADING
    Gollins, Kenneth
    Chiu, Jack
    Shaffren, Daniel
    Delale, Feridun
    Elvin, Niell
    Liaw, Benjamin
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 9, 2017,
  • [25] Strain accumulation process under periodical loading in polymeric materials
    Emri, I.
    Zupancic, B.
    Nikonov, A.
    Florjancic, U.
    TRANSFERABILITY AND APPLICABILITY OF CURRENT MECHANICS APPROACHES, 2009, : 79 - 83
  • [26] Numerical investigation on the wear characteristics of hip implant under static loading
    Abu Qudeiri, Jaber E.
    Abdudeen, Asarudheen
    Sahadevan, Mini Rema
    Padmanabhan, M. Anantha
    HELIYON, 2024, 10 (04)
  • [27] Characterization of heterogeneous materials under shear loading at finite strain
    Abadi, Mohammad Tahaye
    COMPOSITE STRUCTURES, 2010, 92 (02) : 578 - 584
  • [28] Piezoresistance of constantan strain gauges under shock loading conditions
    Cavendish Lab, Cambridge, United Kingdom
    J Phys D, 9 (1126-1130):
  • [29] The piezoresistanse of constantan strain gauges under shock loading conditions
    Millett, J
    Bourne, N
    Rosenberg, Z
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (09) : 1126 - 1130
  • [30] Irregular Implant Design Decreases Periimplant Stress and Strain Under Oblique Loading
    He, Ling
    Zhang, Jiwu
    Li, Xiucheng
    Hu, Hongcheng
    Lu, Songhe
    Tang, Zhihui
    IMPLANT DENTISTRY, 2017, 26 (05) : 744 - 750