An alternative method for radioactivity measurement in quantitative bone SPECT/CT imaging

被引:0
|
作者
Ishihara, Masaru [1 ]
Kato, Yasuaki [2 ]
Onoguchi, Masahisa [3 ]
Shibutani, Takayuki [3 ]
机构
[1] Hyogo Prefectural Kakogawa Med Ctr, Dept Radiol, 203 Kanno, Kakogawa, Hyogo 6758555, Japan
[2] Hyogo Prefectural Awaji Med Ctr, Dept Radiol, Sumoto, Hyogo, Japan
[3] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, Kanazawa, Ishikawa, Japan
关键词
Bone metastasis; SPECT; CT; standardized uptake value; measured value; fixed value; SCINTIGRAPHY; QUANTIFICATION; CANCER;
D O I
10.1177/00368504211028363
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Bone scintigraphy with combined single-photon emission computed tomography (SPECT) and computed tomography (CT) has become widely used for the detection of bone metastases. However, calculation of the semi-quantitative standardized uptake value (SUV) requires measurement of the pre- and post-injection radioactivity of the radiopharmaceutical. This study aimed to compare measured and fixed input radioactivity values for quantitative SPECT/CT bone imaging to examine whether the fixed measurement method of radiopharmaceutical radioactivity could be used as an alternative method. Four different methods were used to quantify the Tc-99m hydroxymethylene diphosphonate input radioactivity: (A) measured pre- and post-injection radioactivity values; (B) measured pre-injection and fixed post-injection radioactivity values; (C) fixed pre-injection and measured post-injection radioactivity values; (D) fixed pre- and post-injection radioactivity values. All SPECT/CT acquisitions were analyzed using bone SPECT analysis software, and the semi-quantitative parameters (SUVpeak and SUVmean) were recorded and compared for each analytical method. Two semi-quantitative parameters showed significant differences between analytical methods A and B, A and D, and C and D. However, an additional subgroup analysis performed on patients whose median post-injection measured radioactivity value was <1.5 MBq showed no significant differences in parameters between all analytical methods. Measurement of the radiopharmaceutical radioactivity can be an alternative method because it reduces the volume of radioactivity post-injection. The simplified fixed measurement method of radiopharmaceutical radioactivity can be used as an alternative method in cases when measuring the radioactivity in quantitative bone SPECT/CT imaging is missed.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] The diagnostic value of quantitative bone SPECT/CT in solitary undetermined bone lesions
    Du, Fen
    Wumener, Xieraili
    Zhang, Yarong
    Liu, Ming
    Li, Taichuang
    Huang, Size
    Zhang, Maoqun
    Wu, Rongliang
    Liang, Ying
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [32] The effect of metal artifact reduction on quantitative SPECT/CT imaging
    Konishi, T.
    Shibutani, T.
    Okuda, K.
    Yoneyama, H.
    Moribe, R.
    Onoguchi, M.
    Nakajima, K.
    Kinuya, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S873 - S873
  • [33] Metal artifact reduction for improving quantitative SPECT/CT imaging
    Takahiro Konishi
    Takayuki Shibutani
    Koichi Okuda
    Hiroto Yoneyama
    Riku Moribe
    Masahisa Onoguchi
    Kenichi Nakajima
    Seigo Kinuya
    Annals of Nuclear Medicine, 2021, 35 : 291 - 298
  • [34] Metal artifact reduction for improving quantitative SPECT/CT imaging
    Konishi, Takahiro
    Shibutani, Takayuki
    Okuda, Koichi
    Yoneyama, Hiroto
    Moribe, Riku
    Onoguchi, Masahisa
    Nakajima, Kenichi
    Kinuya, Seigo
    ANNALS OF NUCLEAR MEDICINE, 2021, 35 (03) : 291 - 298
  • [35] Transmission CT image quality for quantitative brain SPECT imaging
    Hasegawa, H
    Motomura, N
    Ichihara, T
    Ogawa, K
    Hashimoto, J
    Kubo, A
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 964 - 964
  • [36] Quantitative SPECT/CT
    Kuwert, T.
    Ritt, P.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2014, 38 (03): : 200 - 203
  • [37] Optimization of SPECT/CT imaging protocols for quantitative and qualitative 99mTc SPECT
    Dennis Kupitz
    Heiko Wissel
    Jan Wuestemann
    Stephanie Bluemel
    Maciej Pech
    Holger Amthauer
    Michael C. Kreissl
    Oliver S. Grosser
    EJNMMI Physics, 8
  • [38] Optimization of SPECT/CT imaging protocols for quantitative and qualitative 99mTc SPECT
    Kupitz, Dennis
    Wissel, Heiko
    Wuestemann, Jan
    Bluemel, Stephanie
    Pech, Maciej
    Amthauer, Holger
    Kreissl, Michael C.
    Grosser, Oliver S.
    EJNMMI PHYSICS, 2021, 8 (01)
  • [39] Measurement of radioactivity by 3-D imaging for estimating dose: Use of SPECT and PET
    Koral, K
    MEDICAL PHYSICS, 2004, 31 (06) : 1768 - 1768
  • [40] Marble bone disease: The role of SPECT/CT hybrid imaging
    Matrane, A.
    El Issami, S.
    Bsiss, M. A.
    ARCHIVES DE PEDIATRIE, 2016, 23 (07): : 714 - 718