Fuzzy Logic Control of Shunt Active Power Filter for Power Quality Improvement

被引:4
|
作者
Anjana, S. [1 ]
Maya, P. [1 ]
机构
[1] Amrita Vishwa Vidyapeetham, Dept Elect & Elect, Coimbatore, Tamil Nadu, India
关键词
Shunt active filter; Power quality; Harmonics; Fuzzy logic controller; Hysteresis controller; Harmonic compensation; REACTIVE POWER;
D O I
10.1007/978-81-322-2671-0_92
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
With the advent of semiconductor technology, the usage of nonlinear loads in the power system has increased tremendously thereby creating different power quality issues. Shunt active power filters are used to eliminate current harmonics and also for reactive power compensation, which are major power quality issues. In this paper, simulation study of fuzzy logic for shunt active filter is presented. Synchronous reference frame theory is used for current control and fuzzy logic is used for DC link voltage control. The output from current control and voltage control is used for generating switching pulses for shunt active filter using a hysteresis controller. The proposed scheme is simulated using MATLAB/SIMULINK. Results are compared with a conventional control scheme based on PI controller.
引用
收藏
页码:975 / 985
页数:11
相关论文
共 50 条
  • [31] Flatness based control of single phase multicellular shunt active power filter for power quality improvement
    Aourir, M.
    Abouloifa, A.
    El Otmani, F.
    Aouadi, C.
    Hamdoun, A.
    Lachkar, I.
    [J]. 2018 RENEWABLE ENERGIES, POWER SYSTEMS & GREEN INCLUSIVE ECONOMY (REPS-GIE), 2018,
  • [32] Fuzzy logic-based instantaneous power ripple minimization for direct power control applied in a shunt active power filter
    Mohammed Kadem
    Abdelhafid Semmah
    Patrice Wira
    Samira Dahmani
    [J]. Electrical Engineering, 2020, 102 : 1327 - 1338
  • [33] Fuzzy logic-based instantaneous power ripple minimization for direct power control applied in a shunt active power filter
    Kadem, Mohammed
    Semmah, Abdelhafid
    Wira, Patrice
    Dahmani, Samira
    [J]. ELECTRICAL ENGINEERING, 2020, 102 (03) : 1327 - 1338
  • [34] A Control Strategy in Active Power Filter for Power Quality Improvement
    Nohra, A. F. Hanna
    Kanaan, H. Y.
    Fadel, M.
    [J]. 2014 INTERNATIONAL CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2014, : 42 - 47
  • [35] Simulation and performance evaluation of shunt hybrid power filter using fuzzy logic based non-linear control for power quality improvement
    R Balasubramanian
    R Sankaran
    S Palani
    [J]. Sādhanā, 2017, 42 : 1443 - 1452
  • [36] Fuzzy Logic Controlled Hybrid Filter For Power Quality Improvement
    Kumar, Amit
    Bhat, Abdul Hamid
    [J]. 2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 714 - 719
  • [37] Simulation and performance evaluation of shunt hybrid power filter using fuzzy logic based non-linear control for power quality improvement
    Balasubramanian, R.
    Sankaran, R.
    Palani, S.
    [J]. SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2017, 42 (09): : 1443 - 1452
  • [38] The Research on H∞ Control and Fuzzy Control in Shunt Active Power Filter
    Liu, Ruiye
    Zhang, Yuhao
    Wu, Xiaodong
    [J]. 2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1484 - 1487
  • [39] Analysis and experimental evaluation of shunt active power filter for power quality improvement based on predictive direct power control
    Aissa, Oualid
    Moulahoum, Samir
    Colak, Ilhami
    Babes, Badreddine
    Kabache, Nadir
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (25) : 24548 - 24560
  • [40] Analysis and experimental evaluation of shunt active power filter for power quality improvement based on predictive direct power control
    Oualid Aissa
    Samir Moulahoum
    Ilhami Colak
    Badreddine Babes
    Nadir Kabache
    [J]. Environmental Science and Pollution Research, 2018, 25 : 24548 - 24560