Synthesis and analysis of aminochromes by HPLC-photodiode array. Adrenochrome evaluation in rat blood

被引:26
|
作者
Remiao, F
Milhazes, N
Borges, F
Carvalho, F
Bastos, ML
Lemos-Amado, F
Domingues, P
Ferrer-Correia, A
机构
[1] Univ Porto, Fac Farm, CEQUP Serv Toxicol, P-4050047 Oporto, Portugal
[2] Univ Porto, Fac Farm, CEQOFFUP Serv Quim Organ, P-4050047 Oporto, Portugal
[3] Inst Ciencias Saude Norte, P-4585116 Paredes, Portugal
[4] Univ Aveiro, Dept Quim, P-3810123 Aveiro, Portugal
关键词
catecholamines oxidation; enzymatic oxidation; tyrosinase; non-enzymatic oxidation;
D O I
10.1002/bmc.203
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The catecholamine oxidation process induces cardiotoxicity and neurotoxicity. Catecholamines can oxidize to aminochromes through autoxidation or by enzymatic or non-enzymatic catalysis. Although some toxic effects seem to be related to the formation of aminochromes there is still scarce information concerning the identification and evaluation of these compounds in in vivo models. In this study five catecholamines were oxidized to their respective aminochromes: adrenaline/adrenochrome; noradrenaline/noradrenochrome; dopa/dopachrome; dopamine/dopaminochrome; and isoproterenol/isoprenochrome. The evaluation of the catecholamines oxidation profile was performed by HPLC with photodiode array detection and using either enzymatic (tyrosinase) or non-enzymatic [Ag2O, CuSO4, NaIO4 and K3Fe(CN)(6)] catalytic systems. The NaIO4 was found to be the most efficient oxidant of catecholamines. An isocratic reverse-phase HPLC method was developed to analyse each pair of catecholamine-aminochrome. The analytical system was then applied to the detection of adrenochrome in rat blood at 490 nm. Thus, adrenochrome was administered i.p. to rats and its concentration in whole blood was monitored after 5, 15 and 25 min. Blood treatment for adrenochrome evaluation consists of an acidification for protein precipitation followed by a rapid neutralization. The results showed a rapid decrease of adrenochrome concentration in blood after its administration. The adrenochrome present in blood was characterized by UV and tandem mass spectrometry. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:6 / 13
页数:8
相关论文
共 50 条
  • [41] Processing of Cardiac Optical Mapping Data for Cameras with Hexagonally Packed Photodiode Array. K-means Cluster Map for Experimental Data Analysis
    Razumov, Artem
    Ushenin, Konstantin
    Potekhina, Victoria
    Shmarko, Dmitriy
    Solovyova, Olga
    2019 URAL SYMPOSIUM ON BIOMEDICAL ENGINEERING, RADIOELECTRONICS AND INFORMATION TECHNOLOGY (USBEREIT), 2019, : 32 - 35
  • [42] Cost Effective Quantification of Asenapine Maleate in Rat Plasma: Application to Pharmacokinetic Studies by RP-HPLC with Photodiode Array
    Harani Avasarala
    Sathis Kumar Dinakaran
    Vijaya Ratna J.
    Pharmaceutical Chemistry Journal, 2022, 55 : 1261 - 1267
  • [43] Simultaneous HPLC analysis of palm carotenoids and tocopherols using a C-30 column and photodiode array detector
    Darnoko, D
    Cheryan, M
    Moros, E
    Jerrel, J
    Perkins, EG
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (12) : 1873 - 1885
  • [44] Cytotoxicity, In vitro anti-Leishmanial and fingerprint HPLC- photodiode array analysis of the roots of Trillium govanianum
    Khan, Kashif Maqbool
    Nahar, Lutfun
    Mannan, Abdul
    Ul-Haq, Ihsan
    Arfan, Muhammad
    Khan, Ghazanfar Ali
    Hussain, Izhar
    Sarker, Satyajit D.
    NATURAL PRODUCT RESEARCH, 2018, 32 (18) : 2193 - 2201
  • [45] Simultaneous analysis of candesartan cilexetil and hydrochlorothiazide in human plasma and dosage forms using HPLC with a photodiode array detector
    Erk, N
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (15) : 2581 - 2591
  • [46] Evaluation of major caffeic acid derivatives in Echinacea purpurea dietary supplements by HPLC with photodiode array detection and electrospray mass spectrometry
    Li, WK
    Sun, YK
    van Breemen, RB
    Fitzloff, JF
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2004, 27 (16) : 2507 - 2529
  • [47] Quality evaluation of Houttuynia cordata Thunb. by high performance liquid chromatography with photodiode-array detection (HPLC-DAD)
    Yang, Zhan-nan
    Sun, Yi-ming
    Luo, Shi-qiong
    Chen, Jin-wu
    Yu, Zheng-wen
    Sun, Min
    PAKISTAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 27 (02) : 223 - 231
  • [48] Solid-phase extraction study and photodiode array RP-HPLC analysis of xanthine derivatives in human biological fluids
    Papadoyannis, IN
    Samanidou, VF
    Georga, KA
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (16) : 2559 - 2578
  • [50] FLOW-INJECTION SYSTEM WITH PHOTODIODE ARRAY DETECTION AND MULTIVARIATE DATA EVALUATION FOR QUANTIFYING TENIPOSIDE IN BLOOD-PLASMA
    GERRITSEN, MJP
    KATEMAN, G
    VANOPSTAL, MAJ
    VANBENNEKOM, WP
    VANDEGINSTE, BGM
    ANALYTICA CHIMICA ACTA, 1990, 241 (01) : 23 - 30