Minimally invasive cardiac output monitoring: agreement of oesophageal Doppler, LiDCOrapid™ and Vigileo FloTrac™ monitors in non-cardiac surgery

被引:9
|
作者
Phan, T. D. [1 ]
Kluger, R. [1 ]
Wan, C. [1 ]
机构
[1] Univ Melbourne, Dept Anaesthesia & Acute Pain Med, St Vincents Hosp, Melbourne, Vic, Australia
关键词
cardiac output monitoring; clinical monitoring; oesophageal Doppler; arterial pressure-derived cardiac output monitoring; trend analysis; STROKE VOLUME VARIATION; RANDOMIZED CONTROLLED-TRIAL; MAJOR COLORECTAL SURGERY; DIRECTED FLUID THERAPY; RISK SURGICAL-PATIENTS; WAVE-FORM ANALYSIS; PULSE PRESSURE; CIRRHOTIC-PATIENTS; RESPONSIVENESS; OPTIMIZATION;
D O I
10.1177/0310057X1604400313
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
There is lack of data about the agreement of minimally invasive cardiac output monitors, which make it impossible to determine if they are interchangeable or differ objectively in tracking physiological trends. We studied three commonly used devices: the oesophageal Doppler and two arterial pressure based devices, the Vigileo FloTracTM and LiDCOrapidTM. The aim of this study was to compare the agreement of these three monitors in adult patients undergoing elective non -cardiac surgery. Measurements were taken at baseline and after predefined clinical interventions of fluid, metaraminol or ephedrine bolus. From 24 patients, 131 events, averaging 5.2 events per patient, were analysed. The cardiac index of LiDCOrapid versus FloTrac had a mean bias of -6.0% (limits of agreement from -51% to 39%) and concordance of over 80% to the three clinical interventions. The cardiac index of Doppler versus LiDCOrapid and Doppler versus FloTrac, had an increasing negative bias at higher mean cardiac outputs and there was significantly poorer concordance to all interventions. Of the preload -responsive parameters, Doppler stroke volume index, Doppler systolic flow time and FloTrac stroke volume variation were fair at predicting fluid responsiveness while other parameters were poor. While there is reasonable agreement between the two arterial pressure derived cardiac output devices (LiDCOrapid and Vigileo FloTrac), these two devices differ significantly to the oesophageal Doppler technology in response to common clinical intraoperative interventions, representing a limitation to how interchangeable these technologies are in measuring cardiac output.
引用
收藏
页码:382 / 390
页数:9
相关论文
共 50 条
  • [21] Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring
    Sophie Marqué
    Alain Cariou
    Jean-Daniel Chiche
    Pierre Squara
    [J]. Critical Care, 13
  • [22] Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring
    Marque, Sophie
    Cariou, Alain
    Chiche, Jean-Daniel
    Squara, Pierre
    [J]. CRITICAL CARE, 2009, 13 (03)
  • [23] Comparison of cardiac output measurements in critically ill patients: Flotrac/Vigileo vs transthoracic Doppler echocardiography
    McLean, A. S.
    Huang, S. J.
    Kot, M.
    Rajamani, A.
    Hoyling, L.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (04) : 590 - 598
  • [24] Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo®
    Sophie Marqué
    Antoine Gros
    Loic Chimot
    Arnaud Gacouin
    Sylvain Lavoué
    Christophe Camus
    Yves Le Tulzo
    [J]. Journal of Clinical Monitoring and Computing, 2013, 27 : 273 - 279
  • [25] Effect of different doses of remifentanil on cardiac output with FloTrac/Vigileo system during spine surgery
    Asouhidou, I.
    Ioannou, P.
    Kemanetzi, I.
    Vaidis, G.
    Vitoula, C.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 43 - 43
  • [26] Is there still a role for the oesophageal Doppler in cardiac output monitoring?
    Harris, Joseph
    Jones, Conor
    [J]. BRITISH JOURNAL OF HOSPITAL MEDICINE, 2021, 82 (06)
  • [27] FloTrac/Vigileo™ (Third Generation) and MostCare®/PRAM Versus Echocardiography for Cardiac Output Estimation in Vascular Surgery
    Romagnoli, Stefano
    Ricci, Zaccaria
    Romano, Salvatore M.
    Dimizio, Fabio
    Bonicolini, Eleonora
    Quattrone, Diego
    De Gaudio, Raffaele
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (06) : 1114 - 1121
  • [28] Monitoring of Cardiac Output Using a New Smartphone Application (Capstesia) vs. Vigileo FloTrac System
    Nisi, Fulvio
    Melchiorri, Chiara
    Di Grigoli, Paola
    Giustiniano, Enrico
    Cerutti, Elisabetta
    Rispoli, Paolo
    Balagna, Roberto
    [J]. SURGERIES, 2021, 2 (04): : 347 - 356
  • [29] Comparison of cardiac output derived from FloTrac/Vigileo and impedance cardiography during major abdominal surgery
    Kim, Ji-Yeon
    Kim, Bo-Ram
    Lee, Kang-Hun
    Kim, Kyung-Woo
    Kim, Jun-Hyun
    Lee, Sang-Il
    Kim, Kyung-Tae
    Choe, Won-Joo
    Park, Jang-Su
    Kim, Jung-Won
    [J]. JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (04) : 1342 - 1349
  • [30] Comparison of bioimpedance and oesophageal Doppler cardiac output monitoring during abdominal aortic surgery
    HK Jørgensen
    J Bisgaard
    T Gilsaa
    [J]. Critical Care, 16 (Suppl 1):