Fracture of Standard Titanium Mandibular Reconstruction Plates and Preliminary Study of Three-Dimensional Printed Reconstruction Plates

被引:29
|
作者
Almansoori, Akram Abdo [1 ,2 ]
Choung, Han-Wool [3 ]
Kim, Bongju [2 ]
Park, Joo-Young [4 ]
Kim, Soung-Min [4 ]
Lee, Jong-Ho [5 ,6 ]
机构
[1] Seoul Natl Univ, Oral Canc Ctr, Dent Hosp, Seoul, South Korea
[2] Seoul Natl Univ, Clin Translat Res Ctr Dent Sci, Dent Hosp, Seoul, South Korea
[3] Chungang Univ Hosp, Dept Oral & Maxillofacial Surg, Seoul, South Korea
[4] Seoul Natl Univ, Dept Oral & Maxillofacial Surg, Seoul, South Korea
[5] Seoul Natl Univ, Dept Oral & Maxillofacial Surg, Oral Canc Ctr, Seoul, South Korea
[6] Seoul Natl Univ, Clin Translat Res Ctr Dent Sci, Seoul, South Korea
关键词
DEFECTS; RESECTION; SURGERY;
D O I
10.1016/j.joms.2019.07.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: A cohort review was performed to compare the effect of a number of variables on mandible reconstruction plate (R-plate) survival and to identify the potential risk factors for plate fracture. We also reported our preliminary results of 3-dimensional (3D) printed reconstruction plates. Patients and Methods: The data from patients who had undergone mandibular reconstruction using reconstruction plates were evaluated for age, gender, mandibular resection indication, defect site and length, remaining occluded teeth, reconstruction plate type, simultaneous soft or bone tissue reconstruction, and radiotherapy. The plate survival rate was estimated using the Kaplan-Meier curve, and the variables were compared using the log-rank (Mantel-Cox) test. Multifactorial risk correlation was determined using logistic regression analysis. Results: The study included 159 patients who had been followed for 97 +/- 5.4 months. Of the 159 patients, 22 had experienced plate fracture that had occurred within 20 months. Most of the plate fractures had occurred near the mandibular bone stump, passing through the shoulder of the plate hole or the bridge between the subsequent plate holes. The overall survival was 86.2%. Patients with few occluded teeth (type I) had a significantly greater R-plate survival rate compared with those with many occluded teeth (P = .045). Laterocentral "LC'' defects had a significantly lower survival rate (44.4%) compared with lateral "L'' defects (84.5%; P = .00). The survival rates with soft tissue (88.7%) or bone tissue reconstruction (100%) were significantly different compared with that for R-plate alone (40%; P = .000 and P = .004, respectively). Four patients received 3D printed R-plates and were followed for 2 to 8 months (mean, 4 months) with no complications. Conclusions: Patients with many remaining occluded teeth, LC defect, and the absence of simultaneous soft or bone tissue reconstruction were associated with a lower plate survival rate. Bending of the plate increased the incidence of plate fracture, and the use of 3D printed customized R-plates seems a valuable alternative. (C) 2019 Published by Elsevier Inc. on behalf of the American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:153 / 166
页数:14
相关论文
共 50 条
  • [41] Three-dimensional printed titanium chest wall reconstruction for tumor removal in the sternal region
    Wang, Wenzhang
    Yang, Shiyan
    Han, Menghu
    Liu, Haifeng
    Feng, Qing
    Su, Yonglin
    Han, Yi
    Wang, Jin
    JOURNAL OF CARDIOTHORACIC SURGERY, 2024, 19 (01)
  • [42] Necessity of pleura repair in the chest wall reconstruction with three-dimensional printed titanium implant
    Zhang, Hao
    Zhao, Jinbo
    Li, Xiaofei
    Huang, Lijun
    Wang, Lei
    JOURNAL OF THORACIC DISEASE, 2020, 12 (05) : 2713 - 2716
  • [43] The Use of Three-Dimensional Printed Technology for Mandibular Reconstruction in a Rare Case of Giant Odontogenic Myxofibroma
    Yilmaz, Yetkin Zeki
    Elkhatroushi, Taha
    Erdur, Zulkuf Burak
    Karaaltin, Mehmet Veli
    comunoglu, Nil
    Batioglu-Karaaltin, Aysegul
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (07) : E618 - E620
  • [44] Multicenter study on the use of patient-specific CAD/CAM reconstruction plates for mandibular reconstruction
    Frank Wilde
    Henning Hanken
    Florian Probst
    Alexander Schramm
    Max Heiland
    Carl-Peter Cornelius
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 2035 - 2051
  • [45] Multicenter study on the use of patient-specific CAD/CAM reconstruction plates for mandibular reconstruction
    Wilde, Frank
    Hanken, Henning
    Probst, Florian
    Schramm, Alexander
    Heiland, Max
    Cornelius, Carl-Peter
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (12) : 2035 - 2051
  • [46] Long-term comparison of CarBulat™ (pure carbon) and titanium mandibular reconstruction plates
    Szabo, G.
    Barabas, J.
    Nemeth, Z.
    PROCEEDINGS OF THE XVIII CONGRESS OF THE EUROPEAN ASSOCIATION FOR CRANIO-MAXILLO FACIAL SURGERY, 2006, : 141 - +
  • [47] Biomechanical comparison of titanium miniplates versus a variety of CAD/CAM plates in mandibular reconstruction
    Steffen, Claudius
    Sellenschloh, Kay
    Vollmer, Matthias
    Morlock, Michael M.
    Heiland, Max
    Huber, Gerd
    Rendenbach, Carsten
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 111 (111)
  • [48] Clinical Study of Reconstruction Plates Used in the Surgery for Mandibular Discontinuity Defect
    Kawasaki, Goro
    Imayama, Naomi
    Yoshitomi, Izumi
    Furukawa, Kohei
    Umeda, Masahiro
    IN VIVO, 2019, 33 (01): : 191 - 194
  • [49] Three-dimensional printing of patient-specific surgical plates in head and neck reconstruction: A prospective pilot study
    Yang, Wei-fa
    Choi, Wing Shan
    Leung, Yiu Yan
    Curtin, Justin Paul
    Du, Ruxu
    Zhang, Chun-yu
    Chen, Xian-shuai
    Su, Yu-xiong
    ORAL ONCOLOGY, 2018, 78 : 31 - 36
  • [50] Mandibular Reconstruction Using a Customized Three-Dimensional Titanium Implant Applied on the Lingual Surface of the Mandible
    Jo, You-Young
    Kim, Seong-Gon
    Kim, Min-Keun
    Shin, Sung-Ho
    Ahn, Janghoon
    Seok, Hyun
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (02) : 415 - 419