Mastoid obliteration with S53P4 bioactive glass in cholesteatoma surgery

被引:26
|
作者
Mestdagh, Pieter D. de Veij [1 ]
Colnot, David R. [1 ]
Borggreven, Pepijn A. [1 ]
Orelio, Claudia C. [2 ]
Quak, Jasper J. [1 ]
机构
[1] Diakonessenhuis Utrecht, Dept Otolaryngol & Head & Neck Surg, Postbus 80250, NL-3508 TG Utrecht, Netherlands
[2] Diakonessenhuis Utrecht, Res Support, Diakad, Utrecht, Netherlands
关键词
S53P4; bioactive glass; mastoid obliteration; cholesteatoma; CHRONIC OTITIS-MEDIA; TERM-FOLLOW-UP; RECONSTRUCTION;
D O I
10.1080/00016489.2017.1279346
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Conclusion: Evaluation of the follow-up of 67 patients shows that S53P4 bioactive glass (BAG) granules are safe and effective as obliteration material in cholesteatoma surgery. Objectives: To investigate the safety and efficacy of mastoid obliteration using S53P4BAG in cholesteatoma surgery. Clinical outcomes were infection control (Merchant's grading), cholesteatoma recidivism, and audiometric performance. Methods: Retrospective follow-up study at the Diakonessenhuis, Utrecht, the Netherlands. Eighteen young (age <17 years) and 49 adult (age >= 17 years) patients treated for cholesteatoma underwent tympanomastoidectomy with mastoid obliteration using S53P4BAG in the period 2012-2015. Outcome was monitored with clinical otoscopy, otorrhea incidence measurement (Merchant's grading), DW-MRI, and audiographic performance analyses (pure tone average and air bone gap). Results: During the follow-up period (mean=22 months; range=12-54 months) cholesteatoma recidivism was observed in 6% of the patients (four ears), mostly in young patients (three ears). An acceptably dry ear (Merchant grade 0-1) was achieved in 96% of all cases. The remaining 4% of cases scored a Merchant grade 2. Overall, both air conduction thresholds and air bone gap were slightly lowered when comparing post-operative values to pre-operative values and significantly in the case of ossicular reconstruction. In none of the patients (0%) did post-operative wound infections occur.
引用
收藏
页码:690 / 694
页数:5
相关论文
共 50 条
  • [21] In vitro antibiofilm activity of bioactive glass S53P4
    Drago, Lorenzo
    Vassena, Christian
    Fenu, Simone
    De Vecchi, Elena
    Signori, Valentina
    De Francesco, Raffaele
    Romano, Carlo Luca
    [J]. FUTURE MICROBIOLOGY, 2014, 9 (05) : 593 - 601
  • [22] Experimental follow-up model for clinical frontal sinus obliteration with bioactive glass (S53P4)
    Peltola, M
    Suonpää, J
    Aitasalo, K
    Määttänen, H
    Andersson, Ö
    Yli-Urpo, A
    Laippala, P
    [J]. ACTA OTO-LARYNGOLOGICA, 2000, : 167 - 169
  • [23] In vivo model for frontal sinus and calvarial bone defect obliteration with bioactive glass S53P4 and hydroxyapatite
    Peltola, MJ
    Aitasalo, KMJ
    Suonpää, JTK
    Yli-Urpo, A
    Laippala, PJ
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (03): : 261 - 269
  • [24] BioActive Glass S53P4 Used in the Treatment of Bone Infections
    Lupescu, Olivera
    Nagea, Mihail
    Marcov, Narcis
    Jinescu, George
    Popescu, Gheorghe Ion
    [J]. REVISTA DE CHIMIE, 2016, 67 (12): : 2541 - 2544
  • [25] S53P4 Bioactive Glass - an Alternative Treatment of Bone Defects
    Trambitas, Cristian
    Pop, Tudor Sorin
    Miron, Alina Dia Trambitas
    Dorobantu, Dorin Constantin
    Brinzaniuc, Klara
    [J]. REVISTA DE CHIMIE, 2017, 68 (02): : 387 - 389
  • [26] Implantation of the Bonebridge BCI 602 after Mastoid Obliteration with S53P4 Bioactive Glass: A Safe Method of Treating Difficult Anatomical Conditions-Preliminary Results
    Krol, Bartlomiej
    Cywka, Katarzyna Beata
    Skarzynska, Magdalena Beata
    Skarzynski, Piotr Henryk
    [J]. LIFE-BASEL, 2021, 11 (05):
  • [27] Mastoid Obliteration Using S53P4 Bioactive Glass in Cholesteatoma Surgery: A 10-Year Single-Center Experience in 173 Adult Patients with Long-Term Magnetic Resonance Imaging Controlled Follow-up
    Kroon, Victor J.
    Mes, Steven W.
    Borggreven, Pepijn A.
    van de Langenberg, Rick
    Colnot, David R.
    Quak, Jasper J.
    [J]. OTOLOGY & NEUROTOLOGY, 2022, 43 (10) : 1181 - 1188
  • [28] The Obliteration of Noncritical Size Bone Defects With Bone Dust or Bone Replacement Material (Bioactive Glass S53P4)
    Kluge, Anne
    Neudert, Marcus
    Kunert-Keil, Christiane
    Lailach, Susen
    Zahnert, Thomas
    Kemper, Max
    [J]. OTOLOGY & NEUROTOLOGY, 2019, 40 (04) : E415 - E423
  • [29] Preparation and characterization of fluorapatite-bioactive glass S53P4 nanocomposite
    Manafi, Sahebali
    Mirjalili, Fatemeh
    Hajisafari, Mahmood
    Orand, Faranak
    [J]. JOURNAL OF NANOANALYSIS, 2019, 6 (03): : 145 - 156
  • [30] Influence of SrO substitution for CaO on the properties of bioactive glass S53P4
    Massera, Jonathan
    Hupa, Leena
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2014, 25 (03) : 657 - 668