Comparative Accuracy of Facial Models Fabricated Using Traditional and 3D Imaging Techniques

被引:11
|
作者
Lincoln, Ketu P. [1 ]
Sun, Albert Y. T. [2 ]
Prihoda, Thomas J. [3 ]
Sutton, Alan J. [4 ]
机构
[1] USAF, Dept Grad Prosthodont, Joint Base San Antonio L, TX USA
[2] Natl Taipei Univ Technol, Dept Mech Engn, Taipei 106, Taiwan
[3] Univ Texas Hlth Sci Ctr San Antonio, Dept Pathol, San Antonio, TX 78229 USA
[4] Univ Colorado, Dept Restorat Dent, Sch Dent Med, Aurora, CO USA
关键词
Moulage; facial prosthetics; 3D imaging; 3D models; dental materials; stereolithography; rapid prototyping; BEAM COMPUTED-TOMOGRAPHY; DIGITAL 3-DIMENSIONAL PHOTOGRAMMETRY; ANTHROPOMETRIC PRECISION; RELIABILITY; IMAGES; STEREOPHOTOGRAMMETRY; SYSTEM; GENEX; CORPS; HEAD;
D O I
10.1111/jopr.12358
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe purpose of this investigation was to compare the accuracy of facial models fabricated using facial moulage impression methods to the three-dimensional printed (3DP) fabrication methods using soft tissue images obtained from cone beam computed tomography (CBCT) and 3D stereophotogrammetry (3D-SPG) scans. Materials and MethodsA reference phantom model was fabricated using a 3D-SPG image of a human control form with ten fiducial markers placed on common anthropometric landmarks. This image was converted into the investigation control phantom model (CPM) using 3DP methods. The CPM was attached to a camera tripod for ease of image capture. Three CBCT and three 3D-SPG images of the CPM were captured. The DICOM and STL files from the three 3dMD and three CBCT were imported to the 3DP, and six testing models were made. Reversible hydrocolloid and dental stone were used to make three facial moulages of the CPM, and the impressions/casts were poured in type IV gypsum dental stone. A coordinate measuring machine (CMM) was used to measure the distances between each of the ten fiducial markers. Each measurement was made using one point as a static reference to the other nine points. The same measuring procedures were accomplished on all specimens. All measurements were compared between specimens and the control. The data were analyzed using ANOVA and Tukey pairwise comparison of the raters, methods, and fiducial markers. ResultsThe ANOVA multiple comparisons showed significant difference among the three methods (p < 0.05). Further, the interaction of methods versus fiducial markers also showed significant difference (p < 0.05). The CBCT and facial moulage method showed the greatest accuracy. Conclusions3DP models fabricated using 3D-SPG showed statistical difference in comparison to the models fabricated using the traditional method of facial moulage and 3DP models fabricated from CBCT imaging. 3DP models fabricated using 3D-SPG were less accurate than the CPM and models fabricated using facial moulage and CBCT imaging techniques.
引用
收藏
页码:207 / 215
页数:9
相关论文
共 50 条
  • [21] Comparative analysis of RNA secondary structure accuracy on predicted RNA 3D models
    Kulkarni, Mandar
    Thangappan, Jayaraman
    Deb, Indrajit
    Wu, Sangwook
    PLOS ONE, 2023, 18 (09):
  • [22] Analysis of Facial Muscle Activation in Children with Autism using 3D Imaging
    Samad, Manar D.
    Bobzien, Jonna L.
    Harrington, John W.
    Iftekharuddin, Khan M.
    PROCEEDINGS 2015 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE, 2015, : 337 - 342
  • [23] 3D Anthropometric Facial Imaging-A comparison of different 3D scanners
    Koban, Konstantin Christoph
    Perko, Philipp
    Li, Zhouxiao
    Xu, Ya
    Giunta, Riccardo E.
    Alfertshofer, Michael G.
    Kohler, Lukas H.
    Freytag, David L.
    Cotofana, Sebastian
    Frank, Konstantin
    FACIAL PLASTIC SURGERY CLINICS OF NORTH AMERICA, 2022, 30 (02) : 149 - 158
  • [24] Adaptation of Custom Trays Fabricated Using CAD/3D Printer and Manual Techniques
    Sadr, Katayoun
    Ghasemi, Shima
    Garjan, Alireza Hayati
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL AND PHYTOPHARMACOLOGICAL RESEARCH, 2020, 10 (03): : 30 - 36
  • [25] 3D facial and lento-alveolar imaging
    Freezer, Simon
    Fricker, John
    AUSTRALASIAN ORTHODONTIC JOURNAL, 2017, : 73 - 86
  • [26] Evaluation of a Structured Light Scanner for 3D Facial Imaging: A Comparative Study with Direct Anthropometry
    Major, Martin
    Meszaros, Bence
    Wursching, Tamas
    Polyak, Melinda
    Kammerhofer, Gabor
    Nemeth, Zsolt
    Szabo, Gyoergy
    Nagy, Krisztian
    SENSORS, 2024, 24 (16)
  • [27] IDENTIFYING FASD ASSOCIATED FACIAL DYSMORPHOLOGY USING AUTOMATED ANALYSIS OF 2D AND 3D FACIAL IMAGING
    Suttie, M.
    Hammond, P.
    Huang, R.
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2019, 43 : 324A - 324A
  • [28] Statistical generation of 3d facial animable models
    Rudomin, I
    Bojórquez, A
    Cuevas, H
    SHAPE MODELING AND APPLICATIONS, PROCEEDINGS, 2002, : 219 - 226
  • [29] Automatic Pose Estimation of 3D Facial Models
    Sun, Yi
    Yin, Lijun
    19TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOLS 1-6, 2008, : 104 - 107
  • [30] Errors in landmarking and the evaluation of the accuracy of traditional and 3D anthropometry
    Kouchi, Makiko
    Mochimaru, Masaaki
    APPLIED ERGONOMICS, 2011, 42 (03) : 518 - 527