Unsupervised pseudo CT generation using heterogenous multicentric CT/MR images and CycleGAN: Dosimetric assessment for 3D conformal radiotherapy

被引:23
|
作者
Jabbarpour, Amir [1 ]
Mahdavi, Seied Rabi [1 ,2 ]
Sadr, Alireza Vafaei [3 ,9 ,10 ]
Esmaili, Golbarg [4 ]
Shiri, Isaac [5 ]
Zaidi, Habib [5 ,6 ,7 ,8 ]
机构
[1] Iran Univ Med Sci, Sch Med, Med Phys Dept, Tehran, Iran
[2] Iran Univ Med Sci, Radiat Biol Res Ctr, Tehran, Iran
[3] RWTH Aachen Univ Hosp, Inst Pathol, Aachen, Germany
[4] Pars Hosp, Tehran, Iran
[5] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva 4, Switzerland
[6] Univ Geneva, Neuroctr, Geneva, Switzerland
[7] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[8] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[9] Univ Geneva, Dept Theoret Phys, Geneva, Switzerland
[10] Univ Geneva, Ctr Astroparticle Phys, Geneva, Switzerland
基金
瑞士国家科学基金会;
关键词
MRI-Only radiotherapy; Brain tumors; Unsupervised deep learning; CycleGAN; RADIATION-THERAPY; MRI; REGISTRATION;
D O I
10.1016/j.compbiomed.2022.105277
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: Absorbed dose calculation in magnetic resonance-guided radiation therapy (MRgRT) is commonly based on pseudo CT (pCT) images. This study investigated the feasibility of unsupervised pCT generation from MRI using a cycle generative adversarial network (CycleGAN) and a heterogenous multicentric dataset. A dosimetric analysis in three-dimensional conformal radiotherapy (3DCRT) planning was also performed. Material and methods: Overall, 87 T1-weighted and 102 T2-weighted MR images alongside with their corre-sponding computed tomography (CT) images of brain cancer patients from multiple centers were used. Initially, images underwent a number of preprocessing steps, including rigid registration, novel CT Masker, N4 bias field correction, resampling, resizing, and rescaling. To overcome the gradient vanishing problem, residual blocks and mean squared error (MSE) loss function were utilized in the generator and in both networks (generator and discriminator), respectively. The CycleGAN was trained and validated using 70 T1 and 80 T2 randomly selected patients in an unsupervised manner. The remaining patients were used as a holdout test set to report final evaluation metrics. The generated pCTs were validated in the context of 3DCRT. Results: The CycleGAN model using masked T2 images achieved better performance with a mean absolute error (MAE) of 61.87 +/- 22.58 HU, peak signal to noise ratio (PSNR) of 27.05 +/- 2.25 (dB), and structural similarity index metric (SSIM) of 0.84 +/- 0.05 on the test dataset. T1-weighted MR images used for dosimetric assessment revealed a gamma index of 3%, 3 mm, 2%, 2 mm and 1%, 1 mm with acceptance criteria of 98.96%+/- 1.1%, 95% +/- 3.68%, 90.1% +/- 6.05%, respectively. The DVH differences between CTs and pCTs were within 2%. Conclusions: A promising pCT generation model capable of handling heterogenous multicenteric datasets was proposed. All MR sequences performed competitively with no significant difference in pCT generation. The proposed CT Masker proved promising in improving the model accuracy and robustness. There was no significant difference between using T1-weighted and T2-weighted MR images for pCT generation.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Non-rigid registration methods assessment of 3D CT images for head-neck radiotherapy
    Parraga, Adriane
    Pettersson, Johanna
    Susin, Altamiro
    De Craene, Mathieu
    Macq, Benoit
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [22] In Vivo Biological Evaluation of Micro-CT Based 3D Conformal Radiotherapy System
    Nelson, G.
    Rodriguez, M.
    Zhou, H.
    Lee, A.
    Wu, J.
    Tran, P.
    Felsher, D.
    Keall, P.
    Graves, E.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [23] New technique for axillary radiotherapy using 3D CT information
    van Beek, S
    van Vliet-Vroegindeweij, C
    De Jaeger, K
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S93 - S93
  • [24] Use of DICOM-3 CT and MR images for 3D radiation treatment planning
    Yang, CJ
    Swerdloff, S
    Dickerson, GA
    Tilmans, AS
    RADIOLOGY, 1996, 201 : 769 - 769
  • [25] A Dosimetric Comparison of Simultaneous Integrated Breast Radiotherapy Using 3D Conformal, IMRT and Tomotherapy Techniques
    Kirk, M.
    Shah, A.
    Coon, A.
    Jiang, L.
    Dickler, A.
    Griem, K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2902 - +
  • [26] 3D segmentation of abdominal aorta from CT-scan and MR images
    Duquette, Anthony Adam
    Jodoin, Pierre-Marc
    Bouchot, Olivier
    Lalande, Alain
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2012, 36 (04) : 294 - 303
  • [27] Evaluation of 3D operators for the detection of anatomical point landmarks in MR and CT images
    Hartkens, T
    Rohr, K
    Stiehl, HS
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2002, 86 (02) : 118 - 136
  • [28] Parametric modelling and segmentation of vertebral bodies in 3D CT and MR spine images
    Stern, Darko
    Likar, Bostjan
    Pernus, Franjo
    Vrtovec, Tomaz
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (23): : 7505 - 7522
  • [29] Segmentation of vertebral bodies in CT and MR images based on 3D deterministic models
    Stern, Darko
    Vrtovec, Tomaz
    Pernus, Franjo
    Likar, Bostjan
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [30] Texture analysis of 3D bladder cancer CT images for improving radiotherapy planning
    Nailon, William H.
    Redpath, Anthony T.
    McLaren, Duncan B.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 652 - 655