Global urine metabolomics is a rapidly expanding field with the potential to discover biomarkers of disease and exposure. To date, most methods focus on rapid sample preparation, using neat or diluted urine, together with high-throughput analyses, and are poorly suited for detection of low abundance metabolites present in urine samples. In this study, novel methods have been developed to analyze urine by splitless nanoflowUHPLC-nanoESI-TOFMS (nUHPLC-nESI-TOFMS) after preconcentration by solid-phase extraction (SPE), thus enabling significant improvements in analytical sensitivity and coverage of the urinary metabolome. In initial work, urine samples were extracted by both anion and cation exchange mixed-mode polymeric SPE cartridges and qualitatively compared with those using conventional sample preparations using UHPLC-ESI-TOFMS analyses. Compared with neat or diluted urine samples, SPE concentration of urine resulted in detection of additional metabolites including bile acids, lipids, pharmaceuticals, and markers of lifestyle, with little loss of other components of the metabolome. Analyses of SPE preparations by nUHPLC-nESI-TOFMS revealed excellent retention time repeatability with <1% coefficient of variation (CV) for 96% of analyzed peaks. The repeatability of the MS response was <30% CV for >79% of MS features in both negative and positive nESI modes. Compared with UHPLC-ESI-TOFMS, analysis by the nanoplatform enabled detection of signaling molecules important in disease processes including sex steroids, glucocorticoids, eicosanoids, and neurotransmitter metabolites. The significant improvement in sensitivity arising from use of splitless nUHPLC-nESI-TOFMS analyses of SPE-concentrated samples represents a step change in coverage of the urinary metabolome, thereby increasing the potential for biomarker discovery.
引用
收藏
页码:1158 / 1165
页数:8
相关论文
共 50 条
  • [31] Determination of traces of pesticides in water by solid-phase extraction and liquid chromatography ionspray mass spectrometry
    Giraud, D
    Ventura, A
    Camel, V
    Bermond, A
    Arpino, P
    JOURNAL OF CHROMATOGRAPHY A, 1997, 777 (01) : 115 - 125
  • [32] SOLID-PHASE EXTRACTION TECHNIQUES FOR THE DETERMINATION OF GLYCOPYRROLATE FROM EQUINE URINE BY LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    MATASSA, LC
    WOODARD, D
    LEAVITT, RK
    FIRBY, P
    BEAUMIER, P
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (01): : 43 - 48
  • [33] Solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry
    Huang, Jin-Feng
    Xian, Yan-Ping
    Li, Xiu-Ying
    Cai, Wei-Hong
    Li, He
    Lin, Sen-Yu
    He, Min-Heng
    Guo, Xin-Dong
    Modern Food Science and Technology, 2014, 30 (12) : 241 - 246
  • [34] Determination of Tetrodotoxin in Nassarius by Solid-Phase Extraction Ultrafiltration and Liquid Chromatography-Mass Spectrometry
    Luo Hedong
    Jia Yuzhu
    Zhu Baoping
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (06) : 917 - 921
  • [35] On-line solid-phase extraction for liquid chromatography-mass spectrometry analysis of pesticides
    Lucci, Paolo
    Nunez, Oscar
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (20) : 2929 - 2939
  • [36] Comparison of solid-phase extraction and micro-solid-phase extraction for liquid chromatography/mass spectrometry analysis of pesticides in water samples
    Famiglini, G
    Trufelli, H
    Pierini, E
    De Simoni, E
    Mangani, F
    Cappiello, A
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (05) : 941 - 946
  • [37] Optimized extraction of phospholipids and lysophospholipids for nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry
    Byeon, Seul Kee
    Lee, Ju Yong
    Moon, Myeong Hee
    ANALYST, 2012, 137 (02) : 451 - 458
  • [38] Online hyphenation of in-capillary aptamer-functionalized solid-phase microextraction and extraction nanoelectrospray ionization for miniature mass spectrometry analysis
    Lv, Yueguang
    Shang, Yuhan
    Li, Linsen
    Zhang, Ying
    Ma, Qiang
    ANALYST, 2023, 148 (08) : 1815 - 1823
  • [39] Determination of phenprocoumon, warfarin and their monohydroxylated metabolites in human plasma and urine by liquid chromatography-mass spectrometry after solid-phase extraction
    Ufer, M
    Kammerer, B
    Kirchheiner, J
    Rane, A
    Svensson, JO
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 217 - 226
  • [40] Evaluation of matrix solid-phase dispersion extraction for 11 β-agonists in swine feed by liquid chromatography with electrospray ionization tandem mass spectrometry
    Tao, Yanfei
    Zhu, Fangwei
    Chen, Dongmei
    Xie, Shuyu
    Pan Yuanhu
    Wang, Xu
    Liu, Zhenli
    Peng, Dapeng
    Yuan, Zonghui
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (18) : 2574 - 2582