Assessment of Visual Space Recognition in Patients with Visual Field Defects using Head Mounted Display (HMD) System: Case Study with Severe Visual Field Defect

被引:0
|
作者
Sugihara, Shunichi [1 ]
Tanaka, Toshiaki [2 ]
Miyasaka, Tomoya [3 ]
Izumi, Takashi [4 ]
Shimizu, Koichi [1 ]
机构
[1] Hokkaido Univ, Grad Sch Informat Sci & Technol, Kita Ku, N14,W9, Sapporo, Hokkaido 0600814, Japan
[2] Univ Tokyo, Res Ctr Adv Sci & Technol, Meguro Ku, Tokyo 1538904, Japan
[3] Uekusa Gakuen Univ, Wakaba Ku, Chiba 2640007, Japan
[4] Tokai Univ, Sch Int Cultural Relat, Sapporo, Hokkaido 0058601, Japan
关键词
HOMONYMOUS HEMIANOPIA;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For the quantitative assessment of visual field defects of cerebrovascular patients, we developed a new measurement system that could present various kinds of visual information to the patient. In this system, we use a head mounted display as the display device. The quantitative assessment becomes possible by adding the capability to measure the eye movement and the head movement simultaneously by means of a video apparatus of motion analysis. In our study, we examined the effectiveness of this system by applying it to a patient with serious visual field defects. The visual image of the reduced test paper was presented to the patient, the effect on his/her spatial recognition and eye movement was investigated. The results indicated the increase in the ration of visual search in the reduced side. With the reduced image, the decrease of the angular velocity of eye movement was recognized in the visual search in the defected side. In the motion analysis, the head movement was not observed while the eye movements appeared corresponding to each different conditions. This fact led us to confirm that the patient coped with this kind of test by the eye movement. In this analysis, the effectiveness and the usefulness of the developed system were confirmed that enables us to evaluate the abnormal and compensation movement of the eyes.
引用
收藏
页码:6925 / +
页数:4
相关论文
共 50 条
  • [31] Assessment of vision-related quality of life in patients with homonymous visual field defects
    Eleni Papageorgiou
    Gregor Hardiess
    Frank Schaeffel
    Horst Wiethoelter
    Hans-Otto Karnath
    Hanspeter Mallot
    Birgitt Schoenfisch
    Ulrich Schiefer
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 1749 - 1758
  • [32] Assessment of vision-related quality of life in patients with homonymous visual field defects
    Papageorgiou, Eleni
    Hardiess, Gregor
    Schaeffel, Frank
    Wiethoelter, Horst
    Karnath, Hans-Otto
    Mallot, Hanspeter
    Schoenfisch, Birgitt
    Schiefer, Ulrich
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (12) : 1749 - 1758
  • [33] Quantitative visual pathway abnormalities predict visual field defects in patients with pituitary adenomas: a diffusion spectrum imaging study
    Lihong Liang
    Hai Lin
    Fan Lin
    Jihu Yang
    Hanwen Zhang
    Liang Zeng
    Yaqiong Hu
    Weiwu Lan
    Hua Zhong
    Hong Zhang
    Siping Luo
    Yongqian Mo
    Weihua Li
    Yi Lei
    European Radiology, 2021, 31 : 8187 - 8196
  • [34] Quantitative visual pathway abnormalities predict visual field defects in patients with pituitary adenomas: a diffusion spectrum imaging study
    Liang, Lihong
    Lin, Hai
    Lin, Fan
    Yang, Jihu
    Zhang, Hanwen
    Zeng, Liang
    Hu, Yaqiong
    Lan, Weiwu
    Zhong, Hua
    Zhang, Hong
    Luo, Siping
    Mo, Yongqian
    Li, Weihua
    Lei, Yi
    EUROPEAN RADIOLOGY, 2021, 31 (11) : 8187 - 8196
  • [35] Comparing a head-mounted virtual reality perimeter and the Humphrey Field Analyzer for visual field testing in healthy and glaucoma patients
    Phu, Jack
    Wang, Henrietta
    Kalloniatis, Michael
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2024, 44 (01) : 83 - 95
  • [36] Moderate to severe obstructive sleep apnoea patients is associated with a higher incidence of visual field defect
    Tsang, CSL
    Chong, SL
    Ho, CK
    Li, MF
    EYE, 2006, 20 (01) : 38 - 42
  • [37] Moderate to severe obstructive sleep apnoea patients is associated with a higher incidence of visual field defect
    C S L Tsang
    S L Chong
    C K Ho
    M F Li
    Eye, 2006, 20 : 38 - 42
  • [38] Saccadic eye movements and face recognition performance in patients with central glaucomatous visual field defects
    Glen, Fiona C.
    Smith, Nicholas D.
    Crabb, David P.
    VISION RESEARCH, 2013, 82 : 42 - 51
  • [39] Visual Evoked Potential Using Head-Mounted Display Versus Cathode Ray Tube: A Pilot Study
    Choi, Hyo Seon
    Im, Sang Hee
    Kim, Yong Kyun
    Lee, Sang Chul
    ANNALS OF REHABILITATION MEDICINE-ARM, 2016, 40 (02): : 334 - 340
  • [40] Assessment of Visual Field in Patients with Moderate-to-Severe Parkinson's disease (PD)
    Mehta, S.
    Syed, M.
    Naghizadehkashani, S.
    Shivok, K.
    Krisa, L.
    Matias, C.
    Wu, C.
    Liang, T.
    Sergott, R.
    Alizadeh, M.
    MOVEMENT DISORDERS, 2024, 39 : S500 - S501