In vivo continuous glucose monitoring using a chip based near infrared sensor

被引:1
|
作者
Ben Mohammadi, L. [1 ]
Sigloch, S. [1 ]
Frese, I. [1 ]
Welzel, K. [1 ]
Goeddel, M. [1 ]
Klotzbuecher, T. [1 ]
机构
[1] Fraunhofer ICT IMM, D-55129 Mainz, Germany
关键词
continuous glucose monitoring; near infrared difference spectroscopy; microdialysis; diabetes; QUANTITATIVE MICRODIALYSIS; WATER;
D O I
10.1117/12.2052216
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Diabetes is a serious health condition considered to be one of the major healthcare epidemics of modern era. An effective treatment of this disease can be only achieved by reliable continuous information on blood glucose levels. In this work we present a minimally invasive, chip-based near infrared (NIR) sensor, combined with microdialysis, for continuous glucose monitoring (CGM). The sensor principle is based on difference absorption spectroscopy in the 1st overtone band of the near infrared spectrum. The device features a multi-emitter LED and InGaAs-Photodiodes, which are located on a single electronic board (non-disposable part), connected to a personal computer via Bluetooth. The disposable part consists of a chip containing the fluidic connections for microdialysis, two fluidic channels acting as optical transmission cells and total internally reflecting mirrors for in-and out-coupling of the LED light to the chip and to the detectors. The sensor is combined with an intraveneous microdialysis to separate the glucose from the cells and proteins in the blood and operates without any chemical consumption. In vitro measurements showed a linear relationship between glucose concentration and the integrated difference signal with a coefficient of determination of 99 % in the relevant physiological concentration range from 0 to 400 mg/dl. In vivo measurements on 10 patients showed that the NIR-CGM sensor data reflects the blood reference values adequately, if a proper calibration and signal drift compensation is applied. The MARE (mean absolute relative error) value taken over all patient data is 13.8 %. The best achieved MARE value is at 4.8 %, whereas the worst is 25.8 %, with a standard deviation of 5.5 %.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Tissue phantom-based breast cancer detection using continuous near-infrared sensor
    Liu, Dan
    Liu, Xin
    Zhang, Yan
    Wang, Qisong
    Lu, Jingyang
    BIOENGINEERED, 2016, 7 (05) : 321 - 326
  • [42] Role of vascular networks in extending glucose sensor function: Impact of angiogenesis and lymphangiogenesis on continuous glucose monitoring in vivo
    Klueh, Ulrike
    Antar, Omar
    Qiao, Yi
    Kreutzer, Donald L.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2014, 102 (10) : 3512 - 3522
  • [43] Selection of the most informative near infrared spectroscopy wavebands for continuous glucose monitoring in human serum
    Goodarzi, Mohammad
    Saeys, Wouter
    TALANTA, 2016, 146 : 155 - 165
  • [44] Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats
    Woderer, Stefanie
    Henninger, Nadja
    Garthe, Claus-Dieter
    Kloetzer, Hans Martin
    Hajnsek, Martin
    Kamecke, Ulrike
    Gretz, Norbert
    Kraenzlin, Bettina
    Pill, Johannes
    ANALYTICA CHIMICA ACTA, 2007, 581 (01) : 7 - 12
  • [45] A Wireless Powered Implantable Bio-Sensor Tag System-on-Chip for Continuous Glucose Monitoring
    Guan, Shuo
    Gu, Jingren
    Shen, Zhonghan
    Wang, Junyu
    Huang, Yue
    Mason, Andrew
    2011 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2011, : 193 - 196
  • [46] A 186μW Glucose Monitoring SoC using Near-Infrared Photoplethysmography
    Hina, Aminah
    Saadeh, Wala
    2020 IEEE ASIAN SOLID-STATE CIRCUITS CONFERENCE (A-SSCC), 2020,
  • [47] Non-Invasive Blood Glucose Monitoring Using Near Infrared Spectroscopy
    Gayathri, B.
    Sruthi, K.
    Menon, K. A. Unnikrishna
    2017 INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), 2017, : 1139 - 1142
  • [48] Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy
    Repez, Andrej
    Oroszy, Dominika
    Arnez, Zoran M.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2008, 61 (01): : 71 - 77
  • [49] Subcutaneous a continuous glucose monitoring - Feasibility of a new microdialysis-based glucose sensor system
    Jungheim, K
    Wientjes, KJ
    Heinemann, L
    Lodwig, V
    Koschinsky, T
    Koschinsky, T
    Schoonen, AJ
    DIABETES CARE, 2001, 24 (09) : 1696 - 1697
  • [50] A novel glucose sensor system with Au nanoparticles based on microdialysis and coenzymes for continuous glucose monitoring
    Pan, M
    Guo, XS
    Cai, Q
    Li, G
    Chen, YQ
    SENSORS AND ACTUATORS A-PHYSICAL, 2003, 108 (1-3) : 258 - 262