Partial discharge patterns and the identification of defects in high voltage stator windings insulation.

被引:0
|
作者
Kouadria, D [1 ]
Watt, G [1 ]
机构
[1] Eleco Dowding & Mills, Aberdeen, Scotland
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Reliable operation of high voltage (HV) equipment depends largely on the integrity of its insulation [1]. Therefore, the condition of insulating systems, and the early prediction of faults and problems are of major concern to high voltage equipment's manufacturers and users. They allow corrective maintenance and planning and reduce the overall maintenance costs. Partial Electrical discharges (PD) are both a factor that can cause the degradation, ageing and breakdown of HV insulation systems, and an indicator of the actual state and condition of the insulation. Thus, reliable periodic measurement and interpretation of PD activities are of great importance to manufacturer and user of HV equipment. They can enable the detection of a range of insulation problems, which can then be addressed in order to prevent the occurrence of failure and controlled outage of equipment. The introduction of computers and digital equipment has greatly benefited the detection, measurement and identification of PDs. It has allowed better analysis and interpretation of complicated discharge distributions, and providing fast data acquisition, processing and vast amounts of memory space for data storage. An on-line partial discharge detection system has been developed by ELECO Dowding & Mills [2,3], based on more than 12 years experience of PD field tests. The system has been used over the years to monitor, and evaluate the condition of insulating used in the stator windings of HV machines. This paper discuses the relation between the discharge patterns and identification of insulation problems in high voltage stator windings, and how this can help the manufacturer and user to assess ageing and controlled outage of equipment. Practical typical examples from site tests, demonstrating this relationship, are also presented.
引用
收藏
页码:236 / 240
页数:3
相关论文
共 50 条
  • [11] INSULATION DETERIORATION OF HIGH-VOLTAGE STATOR WINDINGS BY HEATING AND COOLING CYCLES
    MATSUNOB.K
    ISOBE, S
    OKA, K
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1973, EI-8 (03): : 111 - 111
  • [12] Searching for Partial Discharge Patterns for the Identification of Defects of Insulation Systems in AC Rotating Machines
    Contin, A.
    Al-Marzouqi, H.
    [J]. 2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 405 - +
  • [13] Voltage Equivalence of Partial Discharge Tests for XLPE Insulation Defects
    Chen, Yun
    Hao, Yanpeng
    Huang, Tao
    Xiao, Jiapeng
    Hui, Baojun
    Chen, Yanwen
    Yang, Lin
    Li, Licheng
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (02) : 683 - 692
  • [14] Identification of stator insulation material partial discharge parameters during lifetime
    Qerkini, A.
    Vogelsberger, M.
    Grubelnik, W.
    Wolbank, T.
    [J]. 2021 IEEE 13TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2021, : 99 - 105
  • [15] Using partial discharge measurement technology to implement predictive maintenance in high voltage motor and generator stator windings
    Stone, G
    Kapler, J
    [J]. 1997 IEEE/PCA CEMENT INDUSTRY TECHNICAL CONFERENCE - XXXIX CONFERENCE RECORD, 1997, : 63 - 68
  • [16] DEVELOPMENT OF A STATIONARY PARTIAL DISCHARGE MONITORING-SYSTEM FOR HIGH-VOLTAGE ROTATING MACHINE STATOR WINDINGS
    ARBOUR, RC
    MILANO, B
    [J]. PROCEEDINGS OF THE 19TH ELECTRICAL ELECTRONICS INSULATION CONFERENCE, 1989, : 212 - 214
  • [17] The practical use of a computerised Partial Discharge measuring system for online condition monitoring of high voltage stator windings
    Watt, G
    Kouadria, D
    [J]. NINTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND DRIVES, 1999, (468): : 112 - 117
  • [18] Partial discharge detection in generator stator insulation using oscillating voltage waves
    Gulski, E
    van Breen, HJ
    Smit, JJ
    Seitz, PN
    Schikarski, P
    [J]. ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, PROCEEDINGS, 2001, : 331 - 334
  • [19] Experience with continuous Partial Discharge monitoring of stator windings
    Fenger, M
    Stone, GC
    Lloyd, BA
    [J]. ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, PROCEEDINGS, 2001, : 417 - 421
  • [20] Locating Partial Discharge Sources in High Voltage Transformer Windings
    Lewin, P. L.
    Golosnoy, I. O.
    Mohamed, R.
    [J]. 2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 196 - 200