Electrocoagulation-electrooxidation for mitigating trace organic compounds in model drinking water sources

被引:14
|
作者
Ryan, Donald R. [1 ]
Maher, Emily K. [1 ]
Heffron, Joe [1 ]
Mayer, Brooke K. [1 ]
McNamara, Patrick J. [1 ]
机构
[1] Marquette Univ, Dept Civil Construct & Environm Engn, Milwaukee, WI 53233 USA
关键词
Electrochemical water treatment; Benzalkonium chloride; Advanced oxidation process (AOP); Electrical energy per order (EEO); Boron-doped diamond; BORON-DOPED DIAMOND; ADVANCED OXIDATION PROCESSES; ELECTROCHEMICAL OXIDATION; IRON-ELECTROCOAGULATION; ANODIC-OXIDATION; REMOVAL; TRIMETHOPRIM; CONTAMINANTS; SULFAMETHOXAZOLE; SURFACTANTS;
D O I
10.1016/j.chemosphere.2020.129377
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In-situ water treatment can be accomplished using electrochemical treatments such as electrocoagulation (EC), which generates coagulants, and electrooxidation (EO), which generates oxidants (e.g., free chlorine and reactive oxygen species) via electrolysis using boron-doped diamond electrodes. In sequential EC-EO, EC can remove oxidant scavengers present in dissolved organic carbon (DOC), thereby improving the efficacy of downstream oxidation via EO. This study evaluated sequential EC-EO (and each process independently for comparison) for mitigating the trace organic compounds (TOrCs) acyclovir (ACY), trimethoprim (TMP), and benzyldimethyldecylammonium chloride (BAC-C10) in model groundwaters and surface waters. EO-only removed greater than 70% of ACY and TMP but negligible BAC-C10 in model groundwaters. In model surface waters, EO-only removed similar to 55-75% BAC-C10, but had less removal for ACY and TMP (similar to 20-55%), primarily due to DOC interference. Sequential-EC-EO was investigated to better gauge the potential process improvement due to the addition of EC ahead of EO. EC removed 74 +/- 7% DOC from model surface water and improved downstream EO treatment relative to EO-only by a factor of 3.4 for ACY, 1.7 for TMP, and 1.4 for BAC-C10. When treating model groundwater, EC-EO resulted in no improvement compared to EO-only for ACY and TMP. BAC-C10 removal was attributed to the particle separation step between EC and EO rather than electrochemical inputs. EO-only treatment was more energy efficient for model groundwater compared to model surface waters based on electrical energy per order (E-EO) values. Sequential EC-EO further improved the energy efficiency for treating model river water. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] DETERMINATION OF ORGANIC-COMPOUNDS IN DRINKING-WATER
    不详
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1977, 69 (04): : 73 - 73
  • [32] Metal type and natural organic matter source for direct filtration electrocoagulation of drinking water
    Dubrawski, Kristian L.
    Fauvel, Milena
    Mohseni, Madjid
    JOURNAL OF HAZARDOUS MATERIALS, 2013, 244 : 135 - 141
  • [33] ANALYSIS OF TRACE HALOGENATED ORGANIC-COMPOUNDS IN WATER
    MILANO, JC
    VERNET, JL
    ANALUSIS, 1981, 9 (07) : 360 - 362
  • [34] Septic systems as sources of organic wastewater compounds in domestic drinking water wells in a shallow sand and gravel aquifer
    Schaider, Laurel A.
    Ackerman, Janet M.
    Rudel, Ruthann A.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 547 : 470 - 481
  • [35] Peculiarities of Preparation of Drinking Water from Surface Sources with High Contents of Natural Organic Compounds, Iron, and Manganese
    O. Yu. Kulishenko
    N. A. Klymenko
    L. A. Savchyna
    S. V. Grechanyk
    L. V. Nevynna
    L. K. Patyuk
    V. A. Kostiuk
    L. P. Avramenko
    Journal of Water Chemistry and Technology, 2021, 43 : 448 - 458
  • [36] Surface microlayer enrichment of volatile organic compounds and semivolatile organic compounds in drinking water source
    Huang, Z
    Zhou, W
    Yu, YJ
    Zhang, AQ
    Han, SK
    Wang, LS
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2004, 16 (01) : 56 - 60
  • [37] Peculiarities of Preparation of Drinking Water from Surface Sources with High Contents of Natural Organic Compounds, Iron, and Manganese
    Kulishenko, O. Yu.
    Klymenko, N. A.
    Savchyna, L. A.
    Grechanyk, S. V.
    Nevynna, L. V.
    Patyuk, L. K.
    Kostiuk, V. A.
    Avramenko, L. P.
    JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY, 2021, 43 (06) : 448 - 458
  • [38] The Reproductive Toxicity of Organic Compounds Extracted from Drinking Water Sources on Sprague Dawley Rats: An In Vitro Study
    Wu, Jiang
    Hu, Guanjiu
    Wang, Xiaoyi
    Li, Dongmei
    Yu, Hongxia
    Han, Xiaodong
    ENVIRONMENTAL TOXICOLOGY, 2010, 25 (03) : 284 - 293
  • [39] The sources of trace element pollution of dry depositions nearby a drinking water source
    Guo, Xinyue
    Ji, Hongbing
    Li, Cai
    Gao, Yang
    Ding, Huaijian
    Tang, Lei
    Feng, Jinguo
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (04) : 3829 - 3842
  • [40] The sources of trace element pollution of dry depositions nearby a drinking water source
    Xinyue Guo
    Hongbing Ji
    Cai Li
    Yang Gao
    Huaijian Ding
    Lei Tang
    Jinguo Feng
    Environmental Science and Pollution Research, 2017, 24 : 3829 - 3842