Spatially Variant Resolution Modelling for Iterative List-Mode PET Reconstruction

被引:0
|
作者
Bickell, Matthew G. [1 ]
Zhou, Lin [1 ]
Nuyts, Johan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, Med Imaging Res Ctr, Leuven, Belgium
来源
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2013年
关键词
IMAGE-RECONSTRUCTION; MATHEMATICAL REMOVAL; BIOGRAPH MCT; EM ALGORITHM; SYSTEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A spatially variant resolution modelling technique is presented which estimates the system matrix on-the-tly. The method randomly redistributes the line-of-response endpoints according to probability density functions describing the detector response and photon acollinearity effects. A list-mode OSEM algorithm is used for the reconstruction. We demonstrate that this model agrees with measured Pit's and we present results showing an improvement in resolution recovery as compared to using a Gaussian convolution to model the resolution, although with an increase in noise. We also present results from applying this method to event-by-event rigid motion correction with list-mode reconstruction using the microPET Focus220 seamier.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Spatially Variant Resolution Modelling for Iterative List-Mode PET Reconstruction
    Bickell, Matthew G.
    Zhou, Lin
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (07) : 1707 - 1718
  • [2] Non-Gaussian space-variant resolution modelling for list-mode reconstruction
    Cloquet, C.
    Sureau, F. C.
    Defrise, M.
    Van Simaeys, G.
    Trotta, N.
    Goldman, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17): : 5045 - 5066
  • [3] Projector with Realistic Detector Scatter Modelling for PET List-Mode Reconstruction
    Autret, Awen
    Bert, Julien
    Strauss, Olivier
    Visvikis, Dimitris
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3333 - 3336
  • [4] A complete implementation of list-mode reconstruction for PET
    ZHANG Bin1 SHAN Baoci2 YUN Mingkai2 ZHAO Shujun(1
    NuclearScienceandTechniques, 2012, 23 (04) : 219 - 225
  • [5] Use of spatially-variant probability density functions in list-mode reconstruction for the HRRT
    Jian, Yiqiang
    Yao, Rutao
    Mulnix, Tim
    Carson, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [6] A complete implementation of list-mode reconstruction for PET
    Zhang Bin
    Shan Baoci
    Yun Mingkai
    Zhao Shujun
    NUCLEAR SCIENCE AND TECHNIQUES, 2012, 23 (04) : 219 - 225
  • [7] Spatiotemporal reconstruction of list-mode PET data
    Nichols, TE
    Qi, JY
    Asma, E
    Leahy, RM
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (04) : 396 - 404
  • [8] Space-variant and anisotropic resolution modeling in list-mode EM reconstruction
    Rahmim, A
    Lenox, M
    Michel, C
    Reader, AJ
    Sossi, V
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3074 - 3077
  • [9] Evaluation of Resolution Properties of Median Priors in List-Mode Reconstruction Methods for PET
    Ahmad, Munir
    Todd-Pokropek, Andrew
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2853 - 2856
  • [10] LMIRA: List-mode iterative reconstruction algorithm for SPECT
    Bouwens, L
    Van de Walle, R
    Gifford, H
    King, M
    Lemahieu, I
    Dierckx, RA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1364 - 1370