Evaluation of Resolution Properties of Median Priors in List-Mode Reconstruction Methods for PET

被引:1
|
作者
Ahmad, Munir [1 ]
Todd-Pokropek, Andrew [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London W1E 6BT, England
来源
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2009年
关键词
LIKELIHOOD;
D O I
10.1109/NSSMIC.2009.5401634
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In list-mode acquisition, data is collected as a list of events with different attributes recorded for each event. List-mode reconstruction methods are used in this case. In this paper, we have contributed towards an assessment of resolution properties of list-mode image reconstruction methods, through an investigation of impulse responses, obtained using Local Impulse Response (LIR) function in Penalized-Likelihood (PL-EM) reconstruction methods with our proposed median root based (MPs) priors and have compared our results with standard quadratic priors (QPs). We have shown that better resolution can be recovered with these priors, whereas standard priors still produce a kind of over-smoothing. We have also presented results for Combine Priors (CPs), a hybrid of standard Quadratic Priors (QPs) and Median Based Priors (MPs), which can be used for better user controlled resolution characteristics, and noise resolution trade-off. Results show that our proposed priors are less sensitive to the parameter value which is a great advantage in PL-EM methods.
引用
收藏
页码:2853 / 2856
页数:4
相关论文
共 50 条
  • [1] Spatially Variant Resolution Modelling for Iterative List-Mode PET Reconstruction
    Bickell, Matthew G.
    Zhou, Lin
    Nuyts, Johan
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [2] Spatially Variant Resolution Modelling for Iterative List-Mode PET Reconstruction
    Bickell, Matthew G.
    Zhou, Lin
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (07) : 1707 - 1718
  • [3] A complete implementation of list-mode reconstruction for PET
    ZHANG Bin1 SHAN Baoci2 YUN Mingkai2 ZHAO Shujun(1
    NuclearScienceandTechniques, 2012, 23 (04) : 219 - 225
  • [4] A complete implementation of list-mode reconstruction for PET
    Zhang Bin
    Shan Baoci
    Yun Mingkai
    Zhao Shujun
    NUCLEAR SCIENCE AND TECHNIQUES, 2012, 23 (04) : 219 - 225
  • [5] Spatiotemporal reconstruction of list-mode PET data
    Nichols, TE
    Qi, JY
    Asma, E
    Leahy, RM
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (04) : 396 - 404
  • [6] Analytic reconstruction methods for list-mode time-of-flight PET
    Kao, Chien-Min
    Guo, Jinxia
    Kim, Heejong
    Xie, Qingguo
    Chen, Chin-Tu
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3492 - 3494
  • [7] Resolution recovery for list-mode reconstruction in SPECT
    Bouwens, LR
    Gifford, H
    Van de Walle, R
    King, MA
    Lemahieu, I
    Dierckx, RA
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 40 - 51
  • [8] Resolution recovery for list-mode reconstruction in SPECT
    Bouwens, LR
    Gifford, H
    Van de Walle, R
    King, MA
    Lemahieu, I
    Dierckx, RA
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08): : 2239 - 2253
  • [9] Calculation of the sensitivity image in list-mode reconstruction for PET
    Qi, Jinyi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2746 - 2751
  • [10] Efficient Rendering of Regions of Response in List-Mode Reconstruction for PET
    Sportelli, Giancarlo
    Ortuno, Juan E.
    Santos, Andres
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4219 - 4221