A new deconvolution method using antidiffusion for high resolution radioisotopic imaging.

被引:0
|
作者
Dornier, C [1 ]
Pousse, A [1 ]
Parmentier, M [1 ]
Delaite, R [1 ]
Kastler, B [1 ]
机构
[1] Univ Franche Comte, Lab Imagerie & Ingn Sante, F-25030 Besancon, France
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radioisotopic investigations are very useful for functional diagnosis. However, visual analysis of images is lowered by blurring due to impulse response size and by their granular aspect due to low statistics. Acquired images result in the convolution between original object and detector spatial impulse response. Classical deconvolution methods used for radioisotopic image restoration fail due to bad signal to noise ratio. A new deconvolution process including two steps is designed. The first stage reduces acquired images statistical noise by applying a 2(nd) order Butterworth low-pass filter. As the detector response shape may also be viewed as a 2D heat diffusion process, the deconvolution is done by running the diffusion equation into minus time. Tests were performed on physical phantom and on clinical thyroid scintigraphies acquired with IRIS (ARIES) high resolution gamma imaging probe. On physical phantom, cold spherical nodules as small as 4 mm in diameter are clearly enhanced on restored images, and diagnosis is improved.
引用
收藏
页码:1388 / 1391
页数:2
相关论文
共 50 条
  • [31] Longitudinal and Case-Control Studies of Human Uterine Peristalses Using High-Resolution Electromyometrial Imaging.
    Wang, Sicheng
    Anderson, Kelsey
    Pizzella, Stephanie
    Sun, Zhexian
    Xu, Haonan
    McNeil, Bri
    Ratts, Valerie
    Wang, Yong
    [J]. REPRODUCTIVE SCIENCES, 2022, 29 (SUPPL 1) : 264 - 264
  • [32] Three dimensional assessment of the trabecular bone structure of the human phalanges using high resolution magnetic resonance imaging.
    Kuhn, B
    Stampa, B
    Heller, M
    Gluer, CC
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 : P304 - P304
  • [33] New optical imaging method for lithography and high-resolution inspections
    Gheen, A
    Wang, Y
    Wang, Z
    [J]. OPTICAL MICROLITHOGRAPHY X, 1997, 3051 : 94 - 105
  • [34] LONGITUDINAL TOMOGRAPHIC RADIOISOTOPIC IMAGING WITH A SCINTILLATION CAMERA - THEORETICAL CONSIDERATIONS OF A NEW METHOD
    MCAFEE, JG
    MOZLEY, JM
    STABLER, EP
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (10) : 654 - &
  • [35] High resolution underwater acoustic image measurement method based on deconvolution
    MEI Jidan
    PEI Yuqing
    SUN Dajun
    SHI Wenpei
    [J]. Chinese Journal of Acoustics, 2020, 39 (04) : 433 - 453
  • [36] High Resolution Radar Range Imaging Method Using Bandwidth Extrapolation
    Chen, Lan
    Chen, Jie
    [J]. 2010 8TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2010, : 6719 - 6723
  • [37] DECONVOLUTION OF SPATIAL-CORRELATION SPECTRA FOR HIGH-RESOLUTION ASTRONOMICAL IMAGING
    AYERS, GR
    [J]. OPTICS LETTERS, 1989, 14 (21) : 1165 - 1167
  • [38] HIGH-RESOLUTION ASTRONOMICAL IMAGING BY ROLL DECONVOLUTION OF SPACE TELESCOPE DATA
    MULLER, M
    WEIGELT, G
    [J]. ASTRONOMY & ASTROPHYSICS, 1987, 175 (1-2) : 312 - 318
  • [39] A new non-invasive method of assessing tumour perfusion and oxygenation using magnetic resonance imaging.
    Goodchild, K
    Saunders, MI
    Griffiths, J
    Taylor, J
    Howe, F
    Robinson, S
    Hoskin, PJ
    Powell, MB
    Baddeley, H
    [J]. BRITISH JOURNAL OF CANCER, 1996, 74 : 55 - 55
  • [40] Detectors for the next generation of high resolution dedicated PET/CT scanners for breast imaging.
    Godinez, F.
    Ferrero, A.
    Chaudhari, A. J.
    Badawi, R. D.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (04) : 661 - 662