Novel experimental approaches to investigate distribution of solar insolation around the tubes in evacuated tube solar collectors

被引:22
|
作者
Jowzi, Mohammad [1 ]
Veysi, Farzad [1 ]
Sadeghi, Gholamabbas [1 ]
机构
[1] Razi Univ, Dept Mech Engn, Fac Engn, Kermanshah, Iran
关键词
Evacuated tube solar collector (ETSC); Experimental study; Radiation around the tube; Theoretical analysis; RADIATION;
D O I
10.1016/j.renene.2018.04.089
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, the exact amount of the rate of irradiance within the ambit of a tube in the evacuated tube solar collector (ETSC) has been measured in various hours of the day by means of a solar meter. Some novel correlations for determining the distribution of insolation intensity around the tube have been proposed by the analysis of experimental data. A correlation is offered by using the results of previous studies and mathematical analysis. The offered correlation is utilized to calculate the direction and the amount of the maximized insolation intensity in cross section area of the tube concerning geographical circumstances, hour angle, and the slope of the collector by denoting the solar radiation distribution function around the section of the tube. Moreover, by integrating around the tube, a correlation for calculation of the whole amount of the absorbed radiation through the absorber has been presented. In the end, the error analysis is conducted and the maximum amount of error for the proposed model is estimated to be 8% before 5 p.m., and at solar noon the amount of error is reported less than 1%. Furthermore, the energy efficiency of the constructed water heater is obtained as 65%. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:724 / 732
页数:9
相关论文
共 50 条
  • [21] Solar Collectors with Evacuated Tubes. Testing Methods - 2.
    Lazzarin, R.
    Grinzato, E.
    1600, (07):
  • [22] Improving the experimental estimation of the incident angle modifier of evacuated tube solar collectors with heat pipes
    Rodriguez-Munoz, J. M.
    Bove, I.
    Alonso-Suarez, R.
    RENEWABLE ENERGY, 2024, 235
  • [23] Thermal characteristics of evacuated tube solar collectors with coil inside: An experimental study and evolutionary algorithms
    Sadeghi, Gholamabbas
    Najafzadeh, Mohammad
    Ameri, Mehran
    RENEWABLE ENERGY, 2020, 151 : 575 - 588
  • [24] Assessment of electricity and hydrogen production performance of evacuated tube solar collectors
    Atiz, Ayhan
    Karakilcik, Hatice
    Erden, Mustafa
    Karakilcik, Mehmet
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (27) : 14137 - 14144
  • [25] On the integration of phase change materials with evacuated tube solar thermal collectors
    Aramesh, M.
    Shabani, B.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 132
  • [26] Thermal and economic analyses of solar desalination system with evacuated tube collectors
    Liu, Xiaohua
    Chen, Wenbo
    Gu, Ming
    Shen, Shengqiang
    Cao, Guojian
    SOLAR ENERGY, 2013, 93 : 144 - 150
  • [27] A comprehensive review of techniques for increasing the efficiency of evacuated tube solar collectors
    Aggarwal, Sorabh
    Kumar, Raj
    Lee, Daeho
    Kumar, Sushil
    Singh, Tej
    HELIYON, 2023, 9 (04)
  • [28] Proof of guaranteed solar yields in solar thermal plants with flat plate and evacuated tube collectors
    Karandashev, Artem
    Eberhardt, Kay
    Gaspar, Paul
    Meißner, Rolf
    Euroheat and Power/Fernwarme International, 2022, 51 (7-8): : 24 - 31
  • [29] ENERGY AND EXERGY EFFICIENCY OF HEAT PIPE EVACUATED TUBE SOLAR COLLECTORS
    Jafarkazemi, Farzad
    Ahmadifard, Emad
    Abdi, Hossein
    THERMAL SCIENCE, 2016, 20 (01): : 327 - 335
  • [30] DESIGN CONSIDERATIONS FOR RESIDENTIAL SOLAR HEATING AND COOLING SYSTEMS UTILIZING EVACUATED TUBE SOLAR COLLECTORS
    WARD, DS
    WARD, JC
    SOLAR ENERGY, 1979, 22 (02) : 113 - 118