24-HOUR INTRAOCULAR PREURE RHYTHM IN YOUNG HEALTHY SUBJECTS EVALUATED WITH CONTINUOUS MONITORING USING CONTACT LENS SENSOR

被引:0
|
作者
Chiquet, Christophe [1 ,2 ]
Mottet, Benjamin [1 ,2 ]
Aptel, Florent [1 ,2 ]
Hubanova, Ralitsa [1 ]
Pepin, Jean-Louis [2 ]
Romanet, Jean-Paul [1 ]
机构
[1] CHU Grenoble, Univ Hosp, Dept Ophthalmol, Grenoble, France
[2] Joseph Fourier Univ, INSERM, U1042, Lab Hypoxia & Physiopathol, Grenoble, France
关键词
568 intraocular preure; 465 clinical (human) or epidemiologic studies: systems/equipment/techniques;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
5626
引用
收藏
页数:2
相关论文
共 50 条
  • [1] 24-hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using contact lens sensor
    Mottet, B.
    Aptel, F.
    Romanet, J. P.
    Hubanova, R.
    Pepin, J. L.
    Chiquet, C.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [2] 24-Hour Intra::ular Pressure Rhythm in Young Healthy Subjects Evaluated With Continuous Monitoring Using a Contact Lens Suisor
    Mottet, Benjamin
    Aptel, Florent
    Romanet, Jean-Paul
    Hubanova, Ralitsa
    Pepin, Jean-Louis
    Chiquet, Christophe
    JAMA OPHTHALMOLOGY, 2013, 131 (12) : 1507 - 1516
  • [3] Continuous 24-Hour Monitoring of Intraocular Pressure Patterns With a Contact Lens Sensor
    Mansouri, Kaweh
    Medeiros, Felipe A.
    Tafreshi, Ali
    Weinreb, Robert N.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (12) : 1534 - 1539
  • [4] Short duration intraocular preure patterns detected by a contact lens sensor for 24-hour recording
    Mansouri, Kaweh
    Weinreb, Robert
    Goedkoop, Rene
    Moshtaghi, Mona
    Dorairaj, Syril
    Tafreshi, Ali
    Liu, John
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] Continuous 24-hour intraocular pressure monitoring in normal Chinese adults using a novel contact lens sensor system
    Zhang, Yuning
    Wei, Yifan
    Lee, Ching Hymn Christopher
    Or, Ping Wai
    Karunaratne, Isuru Kaweendra
    Deng, Mingjie
    Yang, Wenxin
    Chong, Iok Tong
    Yang, Yangfan
    Chen, Zidong
    Fan, Yanmei
    Lam, David C. C.
    Yu, Minbin
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024,
  • [6] Hourly Awakening vs Continuous Contact Lens Sensor Measurements of 24-Hour Intraocular Pressure Effect on Sleep Macrostructure and Intraocular Pressure Rhythm
    Aptel, Florent
    Tamisier, Renaud
    Pepin, Jean-Louis
    Mottet, Benjamin
    Hubanova, Ralitsa
    Romanet, Jean-Paul
    Chiquet, Christophe
    JAMA OPHTHALMOLOGY, 2014, 132 (10) : 1232 - 1238
  • [7] 24-Hour Monitoring of Intraocular Pressure Fluctuations Using a Contact Lens Sensor: Diagnostic Performance for Glaucoma Progression
    Gaboriau, Thibaut
    Dubois, Remi
    Foucque, Boris
    Malet, Florence
    Schweitzer, Cedric
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (03)
  • [8] 24-hour Intraocular Pressure Fluctuation Monitoring Using an Ocular Telemetry Sensor: Tolerability and Functionality in Healthy Subjects
    De Smedt, Stefan
    Mermoud, Andre
    Schnyder, Corinne
    JOURNAL OF GLAUCOMA, 2012, 21 (08) : 539 - 544
  • [9] Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor
    Liu, John H. K.
    Mansouri, Kaweh
    Weinreb, Robert N.
    PLOS ONE, 2015, 10 (06):
  • [10] 24-Hour Intraocular Pressure of Young Healthy Humans in Supine Position: Rhythm and Reproducibility
    Mottet, Benjamin
    Chiquet, Christophe
    Aptel, Florent
    Noel, Christian
    Gronfier, Claude
    Buguet, Alain
    Romanet, Jean-Paul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (13) : 8186 - 8191