24-Hour Monitoring of Intraocular Pressure Fluctuations Using a Contact Lens Sensor: Diagnostic Performance for Glaucoma Progression

被引:7
|
作者
Gaboriau, Thibaut [1 ]
Dubois, Remi [2 ]
Foucque, Boris [1 ]
Malet, Florence [1 ]
Schweitzer, Cedric [1 ,3 ,4 ]
机构
[1] CHU Bordeaux, Dept Ophthalmol, Bordeaux, France
[2] Hop Xavier ArnozanPessac, Electrophysiol & Heart Modeling Inst, IHU Liryc, Pessac, France
[3] Univ Bordeaux, Bordeaux Populat Hlth Res Ctr, Team LEHA, Inserm,UMR 1219, Bordeaux, France
[4] Univ Hosp Pellegrin, Ophthalmol, Pl Amelie Raba Leon, F-33076 Bordeaux, France
关键词
glaucoma; intraocular pressure (IOP); contact lens sensor (CLS); visual field; glaucoma progression; circadian rhythm; VISUAL-FIELD CHANGE; NORMAL-TENSION GLAUCOMA; PRIMARY OPEN-ANGLE; UNTREATED PATIENTS; RATES; REDUCTION; PATTERNS;
D O I
10.1167/iovs.64.3.3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The purpose of this study was to compare 24-hour intraocular pressure (IOP) related fluctuations monitoring between 2 groups of visual field progression rates in patients with open angle glaucoma (OAG). METHODS. Cross-sectional study performed at Bordeaux University Hospital. Twenty -four-hour monitoring was performed using a contact lens sensor (CLS; Triggerfish; SENSIMED, Etagnieres, Switzerland). Progression rate was calculated using a linear regression of the mean deviation (MD) parameter of the visual field test (Octopus; HAAG-STREIT, Switzer-land). Patients were allocated into two groups: group 1 with an MD progression rate <-0.5 dB/year and group 2 with an MD progression rate >=-0.5 dB/year. An automatic signal-processing program was developed and a frequency filtering of the monitoring by wavelet transform analysis was used to compare the output signal between the two groups. A multivariate classifier was performed for prediction of the faster progression group. RESULTS. Fifty-four eyes of 54 patients were included. The mean progression rate was -1.09 +/- 0.60 dB/year in group 1 (n = 22) and -0.12 +/- 0.13 dB/year in group 2 (n = 32). Twenty-four-hour magnitude and absolute area under the monitoring curve were significantly higher in group 1 than in group 2 (group 1: 343.1 +/- 62.3 millivolts [mVs] and 8.28 +/- 2.10 mVs, respectively, group 2: 274.0 +/- 75.0 mV and 6.82 +/- 2.70 mVs respectively, P < 0.05). Magnitude and area under the wavelet curve for short frequency periods ranging from 60 to 220 minutes were also significantly higher in group 1 (P < 0.05). CONCLUSIONS. The 24-hour IOP related fluctuations characteristics, as assessed by a CLS, may act as a risk factor for progression in OAG. In association with other predictive factors of glaucoma progression, the CLS may help adjust treatment strategy earlier.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Continuous 24-Hour Monitoring of Intraocular Pressure Patterns With a Contact Lens Sensor
    Mansouri, Kaweh
    Medeiros, Felipe A.
    Tafreshi, Ali
    Weinreb, Robert N.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (12) : 1534 - 1539
  • [2] Effect of glaucoma medications on 24-hour intraocular pressure-related patterns using a contact lens sensor
    Mansouri, Kaweh
    Medeiros, Felipe A.
    Weinreb, Robert N.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (09): : 787 - 795
  • [3] 24-Hour Contact Lens Sensor Monitoring of Intraocular Pressure-Related Profiles in Normal-Tension Glaucoma and Rates of Disease Progression
    Hoban, Katie
    Peden, Robert
    Megaw, Roly
    Halpin, Patricia
    Tatham, Andrew J.
    OPHTHALMIC RESEARCH, 2017, 57 (04) : 208 - 215
  • [4] Association Between 24-Hour Intraocular Pressure Monitored With Contact Lens Sensor and Visual Field Progression in Older Adults With Glaucoma
    De Moraes, Carlos Gustavo
    Mansouri, Kaweh
    Liebmann, Jeffrey M.
    Ritch, Robert
    JAMA OPHTHALMOLOGY, 2018, 136 (07) : 779 - 785
  • [5] Is 24-hour Intraocular Pressure Monitoring Necessary in Glaucoma?
    Mansouri, Kaweh
    Weinreb, Robert N.
    Medeiros, Felipe A.
    SEMINARS IN OPHTHALMOLOGY, 2013, 28 (03) : 157 - 164
  • [6] Continuous 24 hour intraocular pressure monitoring for glaucoma with a contact lens sensor - time for a paradigm change
    Mansouri, Kaweh
    Weinreb, Robert N.
    SWISS MEDICAL WEEKLY, 2012, 142
  • [7] Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens
    Lorenz, Katrin
    Korb, Christina
    Herzog, Nicola
    Vetter, Jan M.
    Elflein, Heike
    Keilani, Munir M.
    Pfeiffer, Norbert
    JOURNAL OF GLAUCOMA, 2013, 22 (04) : 311 - 316
  • [8] Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor
    Liu, John H. K.
    Mansouri, Kaweh
    Weinreb, Robert N.
    PLOS ONE, 2015, 10 (06):
  • [9] 24-hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using contact lens sensor
    Mottet, B.
    Aptel, F.
    Romanet, J. P.
    Hubanova, R.
    Pepin, J. L.
    Chiquet, C.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [10] Intereye Symmetry of 24-Hour Intraocular Pressure-related Patterns in Untreated Glaucoma Patients Using a Contact Lens Sensor
    Mansouri, Kaweh
    Gillmann, Kevin
    JOURNAL OF GLAUCOMA, 2020, 29 (08) : 666 - 670