Effect of electrode rinse solutions on the electrodialysis of concentrated salts

被引:8
|
作者
Severin, Blaine F. [1 ]
Hayes, Thomas D. [2 ]
机构
[1] Environm Proc Dynam Inc, 4117 Spinnaker Ln, Okemos, MI 48864 USA
[2] Gas Technol Inst, 1700 S Mt Prospect Rd, Des Plaines, IL USA
关键词
Electrodialysis; Concentrated salt; Electrode reaction chemistry; Electrode rinse chemistry; Initiation voltage analysis; Simulation of shale gas waters; MEMBRANE; TECHNOLOGIES; DESALINATION; MONOVALENT; RESISTANCE; SEPARATION; WATER; MODEL; COST;
D O I
10.1016/j.seppur.2021.119048
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The data presented indicate that modest attention to the chemistry of the electrode rinse solution can yield as much as 56% improvement in process efficiency. When operating electrodialysis (ED) with salt concentrations greater than 10,000 mg/l (as NaCl) the amperage can be relatively high even at low voltages. To maximize the overall rate of ion transport from diluate to concentrate, there is a need to minimize resistances in the electrode cells since these can represent as much as 30% of the total resistances in the entire process and in this particular ED unit, represented resistance roughly equivalent to that within the membrane stack. This work describes the performance of a 10-cell pair, 200 cm2 (0.02 m2) per membrane, pilot ED unit operated in batch mode at 5 V potential. The feedstock to the stack was varied from 0.5% to 6% NaCl. Results from Volt-amp profiles (2.0-15 V) were used as the rationale for choosing the preferred electrode rinse solution, 90 g/l (kg/m3) disodium sulfate at pH 12.5. The recommended solution of 30 g/l (kg/m3) disodium sulfate at neutral pH was tested against stronger solutions (60, 90, and 120 g/l (kg/m3) disodium sulfate) at neutral pH and with 1 g/l (kg/m3) sodium hydroxide added to yield solutions at pH 12.5. There were stark differences in the performance of the ED unit between the solutions at pH 7 and those at pH 12.5. The slopes of the Volt-amp profiles improved indicating less resistance to ion flow at pH 12.5. Most of the difference can be attributed to the greater conductivity of sodium hydroxide compared to disodium sulfate, where even a modest addition of 1 g/l (kg/m3) sodium hydroxide increased the conductivity of the solution between 8 and 20% depending on the concentration of disodium sulfate. Most notably, the initiation voltage was 2.39 +/- 0.08 V with solutions at pH 7 and 1.99 V +/- 0.04 V when the rinse solutions were around pH 12.5, a difference of around 0.42 V. Since the full batch runs were performed at 5.0 V, this 0.42 V differential represented a loss of 8% in process efficiency. A series of tests showed a shift in initiation voltage occurred between pH 11.5 and 12.5. Nernst equations for water electrolysis are coupled with a simple flux model that estimates the concentration of hydroxide and hydronium ions at the electrode surfaces. This model indicates that the potential demanded by the electrodes is directly linked to the current. Furthermore, there is a steep drop in the potential demanded by the anode when there is sufficient hydroxide available to generate oxygen from hydroxide as opposed to generation from water. The voltage demand is minimal at pH 12.5 and reflective of the reference standard voltage (just over 1.23 V predicted at 0.1 amps). However, the flux model predicts that the voltage demanded by the electrodes at pH 7 is 1.61 V at 0.1 amps (the lowest amperage measurable with the power pack). Comparing this result to the reference standard (E0 = -1.23 V) yields a satisfactory explanation for the observed difference below reference standard of 0.42 V.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] RAMAN AND INFRARED SPECTROSCOPY OF CONCENTRATED ELECTROLYTE SOLUTIONS AND FUSED SALTS
    HESTER, RE
    [J]. ANNUAL REPORTS ON THE PROGRESS OF CHEMISTRY SECTION A-PHYSICAL & INORGANIC CHEMISTRY, 1969, 66 : 79 - &
  • [42] Immersion electrode for electrodialysis
    Lindner, J
    Figala, N
    [J]. KOLLOID-ZEITSCHRIFT, 1931, 60 (01): : 3 - 6
  • [43] ELECTRODIALYSIS FOR THE RECOVERY OF NICKEL SALTS
    STEWARD, FA
    BAKER, TE
    RESNICK, FJ
    [J]. PLATING AND SURFACE FINISHING, 1985, 72 (05): : 31 - 32
  • [44] ELECTRODIALYSIS OF MONOCARBOXYLIC ACID SALTS
    GRIEVES, RB
    SCHRODT, JT
    KELMAN, S
    [J]. AICHE JOURNAL, 1968, 14 (06) : 963 - &
  • [45] Effect of different aqueous solutions of pure salts and salt mixtures in reverse electrodialysis systems for closed-loop applications
    Micari, M.
    Bevacqua, M.
    Cipollina, A.
    Tamburini, A.
    Van Baak, W.
    Putts, T.
    Micale, G.
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2018, 551 : 315 - 325
  • [46] The effect of neutral salts on ionic reactions in concentrated salt solutions - 1 Monochloroacetate and xanthogenate ionic reactions
    von Kiss, A
    Bossanyi, I
    [J]. RECUEIL DES TRAVAUX CHIMIQUES DES PAYS-BAS, 1934, 53 : 903 - 916
  • [47] Electrodialysis for the concentration of ethanolamine salts
    de Groot, Matheus T.
    Bos, Ardina A. C. M.
    Lazaro, Alicia Pens
    de Rooij, Ralph M.
    Bargeman, Gerrald
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2011, 371 (1-2) : 75 - 83
  • [48] ENGINEERING ASPECTS OF ELECTRODIALYSIS FOR NICKEL PLATING RINSE-WATER
    MARKOVAC, V
    HELLER, HC
    [J]. PLATING AND SURFACE FINISHING, 1982, 69 (01): : 84 - 87
  • [49] RECOVERY OF NICKEL FROM PLATING BATH RINSE WATERS BY ELECTRODIALYSIS
    EISENMANN, JL
    [J]. PLATING AND SURFACE FINISHING, 1977, 64 (11): : 34 - &
  • [50] IONIZATION OF OXYGEN AT A SILVER ELECTRODE IN CONCENTRATED ALKALINE-SOLUTIONS
    KUKUSHKINA, IA
    ZHUTAEVA, GV
    SHTEINBERG, GV
    BAGOTSKII, VS
    [J]. SOVIET ELECTROCHEMISTRY, 1976, 12 (01): : 35 - 39