Improved real-time multiplex polymerase chain reaction detection of methylenetetrahydrofolate reductase (MTHFR) 677C>T and 1298A>C polymorphisms using nearest neighbor model-based probe

被引:5
|
作者
Agarwal, Raghunath P.
Peters, Stephen M.
Shemirani, Manijeh
von Ahsen, Nicolas
机构
[1] Washington Hosp Ctr, Dept Pathol, Washington, DC 20010 USA
[2] Georgetown Univ Hosp, Washington, DC 20007 USA
[3] Georgetown Univ Hosp, Dept Pathol & Lab Med, Washington, DC 20007 USA
[4] Georgetown Univ Hosp, Dept Lab Med, Washington, DC 20007 USA
[5] Univ Gottingen, Dept Clin Chem, D-3400 Gottingen, Germany
来源
JOURNAL OF MOLECULAR DIAGNOSTICS | 2007年 / 9卷 / 03期
关键词
D O I
10.2353/jmoldx.2007.060035
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The disorders of folate metabolism caused by methylenetetrahydrofolate reductase (MTHFR) gene polymorphisms may lead to several disease states including coronary heart disease, venous thrombosis, and several types of cancer. We have developed a real-time multiplex single-tube polymerase chain reaction procedure on the LightCycler for the detection of the two most commonly occurring variants, 677C > T and 1298A > C, in the MTHFR gene. An improved probe design, based on the nearest neighbor model for nucleic acid-probe duplex stability, resulted in a better separation (Delta T-m similar to 10 degrees C) of melting peaks of the wildtype and mutant alleles than that by the existing method (Delta T-m similar to 3 degrees C) for specimens heterozygous for the 1298A > C polymorphism. Of the 333 blood specimens analyzed by this procedure, we did not find any samples that gave ambiguous results. The specimens with homozygous mutation for one polymorphism were of the wild type for the other variant. The assay was validated by the comparison of the genotyping results of 50 blood specimens from the LightCycler polymerase chain reaction with the conventional restriction fragment length polymorphism procedures. There was 100% concordance of the test results obtained by the two techniques. This assay is reliable, economical, and can be performed by less trained technologists compared with the procedure performed by the conventional restriction fragment length polymorphism technique.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 38 条
  • [31] A New and Improved Method Based on Polymerase Chain Reaction-Restriction Fragment Length Polymorphism (PCR-RFLP) for the Determination of A1298C Mutation in the Methylenetetrahydrofolate Reductase (MTHFR) Gene
    Machnik, Grzegorz
    Zapala, Malgorzata
    Pelc, Ewa
    Gasecka-Czapla, Monika
    Kaczmarczyk, Grzegorz
    Okopien, Boguslaw
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2013, 43 (04): : 436 - 440
  • [32] High-speed prothrombin G→A 20210 and methylenetetrahydrofolate reductase C→T 677 mutation detection using real-time fluorescence PCR and melting curves
    Aslanidis, C
    Nauck, M
    Schmitz, G
    BIOTECHNIQUES, 1999, 27 (02) : 234 - +
  • [33] A method for homogeneous color-compensated genotyping of factor V (G1691A) and methylenetetrahydrofolate reductase (C677T) mutations using real-time multiplex fluorescence PCR
    von Ahsen, N
    Oellerich, M
    Schütz, E
    CLINICAL BIOCHEMISTRY, 2000, 33 (07) : 535 - 539
  • [34] High-speed prothrombin G→A 20210 and methylenetetrahydrofolate reductase C→T 677 mutation detection using real-time fluorescence PCR and melting curves.: (vol 27, pg 234, 1999)
    Aslanidis, C
    Nauck, M
    Schmitz, G
    BIOTECHNIQUES, 1999, 27 (05) : 988 - 988
  • [35] Detection of Citrus leprosis virus C using specific primers and TaqMan probe in one-step real-time reverse-transcription polymerase chain reaction assays
    Choudhary, Nandlal
    Wei, G.
    Govindarajulu, A.
    Roy, Avijit
    Li, Wenbin
    Picton, Deric D.
    Nakhla, M. K.
    Levy, L.
    Brlansky, R. H.
    JOURNAL OF VIROLOGICAL METHODS, 2015, 224 : 105 - 109
  • [36] Detection of hepatitis C virus subtypes 6a, 6n, 6w and mixed infections using a modified multiplex real-time polymerase chain reaction protocol
    Lee, Yuan-Ming
    Chen, Yen-Ju
    Lee, Cheng-Ming
    Kuo, Lou-Hui
    Wong, Wing-Wai
    Chen, Yi-Ming Arthur
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2011, 110 (12) : 762 - 767
  • [37] Detection of MDR1 single nucleotide polymorphisms C3435T and G2677T using real-time polymerase chain reaction: MDR1 single nucleotide polymorphism genotyping assay
    Song P.
    Li S.
    Meibohm B.
    Gaber A.O.
    Honaker M.R.
    Kotb M.
    Yates C.R.
    AAPS PharmSci, 4 (4):
  • [38] Detection of MDR1 single nucleotide polymorphisms C3435T and G2677T using real-time polymerase chain reaction: MDR1 single nucleotide polymorphism genotyping assay
    Song, PF
    Li, S
    Meibohm, B
    Gaber, AO
    Honaker, MR
    Kotb, M
    Yates, CR
    AAPS PHARMSCI, 2002, 4 (04):