A Novel Piezoresistive Accelerometer with SPBs to Improve the Tradeoff between the Sensitivity and the Resonant Frequency

被引:21
|
作者
Xu, Yu [1 ]
Zhao, Libo [1 ]
Jiang, Zhuangde [1 ]
Ding, Jianjun [1 ]
Peng, Niancai [1 ]
Zhao, Yulong [1 ]
机构
[1] Xi An Jiao Tong Univ, Collaborat Innovat Ctr Suzhou Nano Sci & Technol, State Key Lab Mfg Syst Engn, Xian 710049, Peoples R China
来源
SENSORS | 2016年 / 16卷 / 02期
基金
中国国家自然科学基金;
关键词
sensitivity; resonant frequency; SPBs; piezoresistive accelerometer; CANTILEVER-TYPE; DESIGN; SENSORS;
D O I
10.3390/s16020210
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For improving the tradeoff between the sensitivity and the resonant frequency of piezoresistive accelerometers, the dependency between the stress of the piezoresistor and the displacement of the structure is taken into consideration in this paper. In order to weaken the dependency, a novel structure with suspended piezoresistive beams (SPBs) is designed, and a theoretical model is established for calculating the location of SPBs, the stress of SPBs and the resonant frequency of the whole structure. Finite element method (FEM) simulations, comparative simulations and experiments are carried out to verify the good agreement with the theoretical model. It is demonstrated that increasing the sensitivity greatly without sacrificing the resonant frequency is possible in the piezoresistive accelerometer design. Therefore, the proposed structure with SPBs is potentially a novel option for improving the tradeoff between the sensitivity and the resonant frequency of piezoresistive accelerometers.
引用
收藏
页数:15
相关论文
共 23 条
  • [11] Frequency robustness design of electrostatic stiffness resonant micro accelerometer based on error sensitivity
    Zhou W.
    He X.
    Su W.
    Li B.
    Zhang F.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2010, 46 (10): : 14 - 18
  • [12] Novel piezoresistive high-g accelerometer geometry with very high sensitivity-bandwidth product
    Kuells, Robert
    Nau, Siegfried
    Salk, Manfred
    Thoma, Klaus
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 182 : 41 - 48
  • [13] A micromachined piezoresistive high-g accelerometer with high sensitivity and wide frequency-band: Design and modeling
    Wang, ZK
    Zong, DG
    Lu, DR
    Xiong, B
    Wang, YL
    Bao, MH
    INTERNATIONAL JOURNAL OF NONLINEAR SCIENCES AND NUMERICAL SIMULATION, 2002, 3 (3-4) : 307 - 310
  • [14] Sensitivity and temperature behavior of a novel z-axis differential resonant micro accelerometer
    Comi, C.
    Corigliano, A.
    Langfelder, G.
    Zega, V.
    Zerbini, S.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2016, 26 (03)
  • [15] A pre-relaxed FBG accelerometer using transverse forces with high sensitivity and improved resonant frequency
    Li, Kuo
    Li, Yuqing
    Liu, Guoyong
    Tian, Juan
    Wang, Yanchun
    PHOTONICS LETTERS OF POLAND, 2020, 12 (01) : 4 - 6
  • [16] High-Quality Factor FBG-FPI Accelerometer With Adjustable Resonant Frequency and Sensitivity Using Additional Mass
    Geng, Fanxu
    Li, Xingyong
    Liu, Xin
    Li, Shuangshuang
    Wang, Ruohui
    Chen, Fengyi
    Qiao, Xueguang
    IEEE SENSORS JOURNAL, 2024, 24 (24) : 40979 - 40987
  • [17] Quantification of the Tradeoff between Test Sensitivity and Test Frequency in a COVID-19 Epidemic-A Multi-Scale Modeling Approach
    Forde, Jonathan E.
    Ciupe, Stanca M.
    VIRUSES-BASEL, 2021, 13 (03):
  • [18] Multi-objective optimization of a circular dual back-plate MEMS microphone: tradeoff between pull-in voltage, sensitivity and resonance frequency
    Saadatmand, Milad
    Kook, Junghwan
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2019, 25 (08): : 2937 - 2947
  • [19] Multi-objective optimization of a circular dual back-plate MEMS microphone: tradeoff between pull-in voltage, sensitivity and resonance frequency
    Milad Saadatmand
    Junghwan Kook
    Microsystem Technologies, 2019, 25 : 2937 - 2947
  • [20] An alternative solution to improve sensitivity of resonant microcantilever chemical sensors:: comparison between using high-order modes and reducing dimensions
    Lochon, F
    Dufour, I
    Rebière, D
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2): : 979 - 985