Discussion on the Application of Variable-air-volume Air-conditioning System on Ships

被引:0
|
作者
Guo, Junjie [1 ]
Chen, Wu [1 ]
Cai, Zhenxiong [1 ]
Zheng, Chaoyu [1 ]
机构
[1] Jimei Univ, Inst Marine Engn, Xiamen, Fujian, Peoples R China
关键词
Ship; Variable-air-volume system; Application; Control;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A scheme of marine VAV A/C systems was presented in this paper. The system flow is as follows: the return air form air-conditioned cabin is mixed with fresh air before the cooling coil-direct expansion (DX) evaporator. The temperature and humidity of mixed-air through the evaporator are reduced. The processed air is supplied by fan and enters air-conditioned cabins through respective VAV terminals. The following differences between marine VAV A/C systems and land-use VAV A/C systems were introduced in detail (1) the VAV air-distribution system is connected with the refrigerating unit directly, no intermediate chilled water system exists. (2) The system capacity is relatively small and the number of VAV terminals in the system is few, hence the regulation and variation of damper opening in terminals are comparatively frequent. (3) The system load and total supply air flow rate have a large varying range. (4) Controls of system air-side and refrigerating-unit side interfere with each other directly. The controls of supply air humidity, cabin air temperature, supply air static pressure and supply air temperature, and the direct-digital-control DDC technology for the marine VAV A/C system were analyzed. The high-quality control for cabin air temperatures and the desirable independent zoning control were expected to be achieved. It was found that the application of such a system on ships should be feasible and promising.
引用
收藏
页码:413 / 418
页数:6
相关论文
共 50 条
  • [21] Coordinated optimization of the variable refrigerant flow and variable air volume combined air-conditioning system in heating conditions
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    He, Chao
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 904 - 916
  • [22] CGPC: An application to an air-conditioning system
    Petrault, C
    Mehdi, D
    Trigeassou, JC
    [J]. PROCEEDINGS OF THE 1997 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 1997, : 1951 - 1952
  • [23] LIMITATIONS AND PROBLEMS OF VARIABLE-AIR-VOLUME SYSTEMS
    HIGHTOWER, G
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1977, 19 (12): : 39 - 39
  • [24] Genetic-algorithm-optimized fuzzy logic control of a variable air volume air-conditioning system
    Huang, Yonghong
    Li, Nianping
    Yu, Tao
    Shi, Yangchun
    [J]. DYNAMICS OF CONTINUOUS DISCRETE AND IMPULSIVE SYSTEMS-SERIES B-APPLICATIONS & ALGORITHMS, 2006, 13E : 2643 - 2647
  • [25] Indoor air quality and the variable-air-volume bypass filtration system: Chamber experiment
    Moschandreas, DJ
    Choi, SW
    Meckler, MM
    [J]. ENVIRONMENT INTERNATIONAL, 1996, 22 (02) : 149 - 158
  • [26] A proactive fault detection and diagnosis method for variable-air-volume terminals in building air conditioning systems
    Zhao, Yang
    Li, Tingting
    Fan, Cheng
    Lu, Jingchao
    Zhang, Xuejun
    Zhang, Chaobo
    Chen, Shuqin
    [J]. ENERGY AND BUILDINGS, 2019, 183 : 527 - 537
  • [27] Analysis of Fresh Air Volume of Air-conditioning System for Railway Vehicles
    PU Dong
    GAO Fei
    [J]. International Journal of Plant Engineering and Management, 2018, 23 (03) : 172 - 178
  • [28] Modelling and simulation of a variable speed air-conditioning system
    Popescu, M. C.
    Petrisor, A.
    Drighiciu, M. A.
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS (AQTR 2008), THETA 16TH EDITION, VOL II, PROCEEDINGS, 2008, : 115 - 120
  • [29] Application of AFNNC to Fresh Air-conditioning System
    Wang Lili
    Zhang Tao
    [J]. PROCEEDINGS OF THE 2012 24TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2012, : 2777 - 2782