Automated Compression Device for Viscoelasticity Imaging

被引:13
|
作者
Nabavizadeh, Alireza [1 ,2 ]
Kinnick, Randall R. [2 ]
Bayat, Mahdi [2 ]
Amador, Carolina [2 ]
Urban, Matthew W. [3 ,4 ]
Alizad, Azra [3 ,4 ]
Fatemi, Mostafa [2 ]
机构
[1] Univ Minnesota Rochester, Biomed Informat & Computat Biol, Rochester, MN 55904 USA
[2] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[3] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[4] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
Creep response; retardation time; ultrasound; viscoelasticity; ACOUSTIC RADIATION FORCE; IN-VIVO; TISSUE ELASTICITY; SOFT-TISSUE; ULTRASOUND ELASTOGRAPHY; EXTRACELLULAR-MATRIX; BREAST-LESIONS; ACQUISITION; PARAMETERS; DISPERSION;
D O I
10.1109/TBME.2016.2612541
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Noninvasive measurement of tissue viscoelastic properties is gaining more attention for screening and diagnostic purposes. Recently, measuring dynamic response of tissue under a constant force has been studied for estimation of tissue viscoelastic properties in terms of retardation times. The essential part of such a test is an instrument that is capable of creating a controlled axial force and is suitable for clinical applications. Such a device should be lightweight, portable, and easy to use for patient studies to capture tissue dynamics under external stress. In this paper, we present the design of an automated compression device for studying the creep response of materials with tissue-like behaviors. The device can be used to apply a ramp-and-hold force excitation for a predetermined duration of time and it houses an ultrasound probe for monitoring the creep response of the underlying tissue. To validate the performance of the device, several creep tests were performed on tissue-mimicking phantoms, and the results were compared against those from a commercial mechanical testing instrument. Using a second-order Kelvin-Voigt model and surface measurement of the forces and displacements, retardation times T-1 and T-2 were estimated from each test. These tests showed strong agreement between our automated compression device and the commercial mechanical testing system, with an average relative error of 2.9% and 12.4%, for T-1 and T-2, respectively. Also, we present the application of compression device to measure local retardation times for four different phantoms with different size and stiffness.
引用
收藏
页码:1535 / 1546
页数:12
相关论文
共 50 条
  • [31] Automated estimate of fish abundance through the autonomous imaging device GUARD1
    Marini, Simone
    Corgnati, Lorenzo
    Mantovani, Carlo
    Bastianini, Mauro
    Ottaviani, Ennio
    Fanelli, Emanuela
    Aguzzi, Jacopo
    Griffa, Annalisa
    Poulain, Pierre-Marie
    MEASUREMENT, 2018, 126 : 72 - 75
  • [32] Real-Time, Automated, Multiobjective, Cloud Computing Whole Slide Imaging Device
    Mallick, Satya Prasanna
    Adithya, K. S.
    Sabui, Ratul
    Naidu, Balu Babu
    Singh, Ranjeet
    Babu, Harish
    Jagadeesh, Gajula
    Amaresh, K. M. Venkata
    Gopal, Ram
    Sharma, Vandana
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [33] An Automated Vertebrae Localization, Segmentation, and Osteoporotic Compression Fracture Detection Pipeline for Computed Tomographic Imaging
    Potter, Ilkay Yildiz
    Rodriguez, Edward K.
    Wu, Jim
    Nazarian, Ara
    Vaziri, Ashkan
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024, 37 (05): : 2428 - 2443
  • [34] Design of a resonator device for in vivo measurement of regional tissue viscoelasticity
    Dhar, Parag R.
    Zu, Jean W.
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 133 (01) : 45 - 54
  • [35] MEASUREMENT OF GLIOMA VISCOELASTICITY USING A HANDHELD PALPATION IMITATION DEVICE
    Hayashi, Shigeto
    Sakuma, Atsushi
    Sasayama, Takashi
    Kohmura, Eiji
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017, VOL 3, 2018,
  • [36] Characterizing the tension-compression asymmetric viscoelasticity of asphalt mixture using the uniaxial tension and compression test
    Tong, Jusheng
    Shen, Kairen
    Ma, Tao
    Zhang, Jinglin
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 350
  • [37] TOURNIQUET COMPRESSION OF A NORPLANT DEVICE
    WRIGHT, TW
    ENNEKING, FK
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (06): : 1006 - 1007
  • [38] Automated region-based hybrid compression for digital imaging and communications in medicine magnetic resonance imaging images for telemedicine applications
    Bairagi, V. K.
    Sapkal, A. M.
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2012, 6 (04) : 247 - 253
  • [39] A device for simultaneous live cell imaging during uni-axial mechanical strain or compression
    Gerstmair, Axel
    Fois, Giorgio
    Innerbichler, Siegfried
    Dietl, Paul
    Felder, Edward
    JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (02) : 613 - 620
  • [40] 3D-printable cell crowding device enables imaging of live cells in compression
    Dow, Liam P.
    Khankhel, Aimal H.
    Abram, John
    Valentine, Megan T.
    BIOTECHNIQUES, 2020, 68 (05) : 275 - 278