Automated Compression Device for Viscoelasticity Imaging

被引:13
|
作者
Nabavizadeh, Alireza [1 ,2 ]
Kinnick, Randall R. [2 ]
Bayat, Mahdi [2 ]
Amador, Carolina [2 ]
Urban, Matthew W. [3 ,4 ]
Alizad, Azra [3 ,4 ]
Fatemi, Mostafa [2 ]
机构
[1] Univ Minnesota Rochester, Biomed Informat & Computat Biol, Rochester, MN 55904 USA
[2] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[3] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[4] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
Creep response; retardation time; ultrasound; viscoelasticity; ACOUSTIC RADIATION FORCE; IN-VIVO; TISSUE ELASTICITY; SOFT-TISSUE; ULTRASOUND ELASTOGRAPHY; EXTRACELLULAR-MATRIX; BREAST-LESIONS; ACQUISITION; PARAMETERS; DISPERSION;
D O I
10.1109/TBME.2016.2612541
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Noninvasive measurement of tissue viscoelastic properties is gaining more attention for screening and diagnostic purposes. Recently, measuring dynamic response of tissue under a constant force has been studied for estimation of tissue viscoelastic properties in terms of retardation times. The essential part of such a test is an instrument that is capable of creating a controlled axial force and is suitable for clinical applications. Such a device should be lightweight, portable, and easy to use for patient studies to capture tissue dynamics under external stress. In this paper, we present the design of an automated compression device for studying the creep response of materials with tissue-like behaviors. The device can be used to apply a ramp-and-hold force excitation for a predetermined duration of time and it houses an ultrasound probe for monitoring the creep response of the underlying tissue. To validate the performance of the device, several creep tests were performed on tissue-mimicking phantoms, and the results were compared against those from a commercial mechanical testing instrument. Using a second-order Kelvin-Voigt model and surface measurement of the forces and displacements, retardation times T-1 and T-2 were estimated from each test. These tests showed strong agreement between our automated compression device and the commercial mechanical testing system, with an average relative error of 2.9% and 12.4%, for T-1 and T-2, respectively. Also, we present the application of compression device to measure local retardation times for four different phantoms with different size and stiffness.
引用
收藏
页码:1535 / 1546
页数:12
相关论文
共 50 条
  • [1] Intraoperative Use of an Automated Chest Compression Device
    Dumans-Nizard, Virginie
    Fischler, Marc
    ANESTHESIOLOGY, 2011, 114 (05) : 1253 - 1255
  • [2] AN UNCOMMON COMPLICATION OF AN AUTOMATED CHEST COMPRESSION DEVICE
    Schutte, Bryce
    Frederickson, Joseph A.
    Sahasranaman, Venketraman
    CHEST, 2023, 164 (04) : 5437A - 5437A
  • [3] Automated device equal to manual chest compression
    Slawson, David
    AMERICAN FAMILY PHYSICIAN, 2006, 74 (07) : 1191 - 1192
  • [4] RESUSCITATION, PROLONGED CARDIAC ARREST, AND AN AUTOMATED CHEST COMPRESSION DEVICE
    Risom, Martin
    Jorgensen, Henrik
    Rasmussen, Lars S.
    Sorensen, Anne Marie
    JOURNAL OF EMERGENCY MEDICINE, 2010, 38 (04): : 481 - 483
  • [5] Pericardial laceration after using an automated mechanical chest compression device
    Ondruschka, B.
    Hartwig, T.
    Gries, A.
    Haedrich, C.
    Dressler, J.
    Bernhard, M.
    NOTFALL & RETTUNGSMEDIZIN, 2017, 20 (05): : 424 - 429
  • [6] Shear and compression viscoelasticity in polymer monolayers
    Ferenczi, TAM
    Cicuta, P
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2005, 17 (45) : S3445 - S3453
  • [7] Viscoelasticity of Tendons Under Transverse Compression
    Buckley, C. Paul
    Salisbury, S. T. Samuel
    Zavatsky, Amy B.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (10):
  • [8] Use of an automated chest compression device during CPR in our cath lab
    Koufakis, N.
    Gata, V.
    Theodorakopoulou, A.
    Stasinopoulou, A.
    Antoniadou, F.
    Biliardis, C. H.
    Kazantza, G.
    Latsios, G.
    Tousoulis, D.
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2016, 15 : S91 - S91
  • [9] Modeling of the nonlinear viscoelasticity of polyoxymethylene in tension and compression
    Tscharnuter, D.
    Gastl, S.
    Pinter, G.
    INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 2012, 60 : 37 - 52
  • [10] A biopsy compression device for use in cross-sectional or fluoroscopic imaging
    Dachman, AH
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) : 703 - 705