Defect detection in CFRP by infrared thermography with CO2 Laser excitation compared to conventional lock-in infrared thermography

被引:27
|
作者
Keo, Sam Ang [1 ,2 ]
Brachelet, Franck [1 ,2 ]
Breaban, Florin [1 ,3 ]
Defer, Didier [1 ,2 ]
机构
[1] PRES Lille Nord France, Lab Genie Civil & GeoEnvironm, Lille, France
[2] Fac Sci Appl, F-62400 Bethune, France
[3] Inst Univ Technol, F-62400 Bethune, France
关键词
Carbon fiber; Defects; Non-destructive testing; CO2; Laser; CONCRETE;
D O I
10.1016/j.compositesb.2014.09.018
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a NOT by a CO2 Laser infrared thermography applied to defect detection in CFRP. The CO2 Laser is an infrared laser with the wavelength of 10.6 mu m. This excitation has a controllable heating beam by a geometric relation D = 0.01575.d, which allows to heat the samples at a specific position (placed at the distance "d") and area (of a diameter "D"). The PPT interpretation principle was used to reduce the non-uniformity's effect of the excitation causing inhomogeneous heat. The test with this excitation is much faster than the tests with conventional lock-in thermography method. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [31] Research and Application of Laser Infrared Thermography in Material Defect Detection
    Wang B.
    Dong L.
    Wang H.
    Kang J.
    Guo W.
    Xiang M.
    Cailiao Daobao/Materials Reports, 2020, 34 (03): : 05127 - 05132
  • [32] Spatial and temporal deep learning for defect detection with lock-in thermography
    Schmid, Simon
    Reinhardt, Juliana
    Grosse, Christian U.
    NDT & E INTERNATIONAL, 2024, 143
  • [33] Nondestructive detection of CFRP subsurface defects using transient lock-in thermography
    Luo, Zhitao
    Wang, Han
    Huang, Yangdong
    Shen, Peng
    Zheng, Enlai
    Zhang, Hui
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024,
  • [34] EXPERIMENTAL STUDY ON DEFECTS DETECTION IN GFRP LAMINATES USING LOCK-IN INFRARED THERMOGRAPHY TECHNOLOGY
    Tang, Qing-Ju
    Qu, Ze-Shen
    Xu, Gui-Peng
    Tan, Xin-Jie
    THERMAL SCIENCE, 2024, 28 (2A): : 1169 - 1174
  • [35] EXPERIMENTAL STUDY ON DEFECTS DETECTION IN GFRP LAMINATES USING LOCK-IN INFRARED THERMOGRAPHY TECHNOLOGY
    Tang, Qing-Ju
    Qu, Ze-Shen
    Xu, Gui-Peng
    Tan, Xin-Jie
    THERMAL SCIENCE, 2024, 28 (02): : 1169 - 1174
  • [37] On-power detection of wall-thinned defects using lock-in infrared thermography
    Yoo, Kwae Hwan
    Kim, Ju Hyun
    Na, Man Gyun
    Kim, Jin Weon
    Kim, Kyeong Suk
    NUCLEAR ENGINEERING AND DESIGN, 2014, 280 : 542 - 549
  • [38] Infrared Lock-in Thermography Crack Localization on Metallic Surfaces for Industrial Diagnosis
    Y. Fedala
    M. Streza
    F. Sepulveda
    J.-P. Roger
    G. Tessier
    C. Boué
    Journal of Nondestructive Evaluation, 2014, 33 : 335 - 341
  • [39] The factors study of backside hotspot localization with application Infrared Lock-in Thermography
    Hoe, T. M.
    Ng, K. K.
    PROCEEDINGS OF THE 22ND INTERNATIONAL SYMPOSIUM ON THE PHYSICAL AND FAILURE ANALYSIS OF INTEGRATED CIRCUITS (IPFA 2015), 2015, : 230 - 235
  • [40] Investigation of factors affecting backside hotspot localization in infrared lock-in thermography
    Koh, Nicholas Chiu Yen
    Sim, Kok Swee
    Hoe, Tiong Min
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2015, 14 (03):