Phagosomal pH determination by dual fluorescence flow cytometry

被引:45
|
作者
Vergne, I
Constant, A
Lanéelle, G
机构
[1] CNRS, Inst Pharmacol & Biol Struct, F-31062 Toulouse, France
[2] Univ Toulouse 3, F-31062 Toulouse, France
关键词
D O I
10.1006/abio.1997.2466
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Several methods have been developed to measure the pH of phagosomes, using fluorescein derivatives as reporter of pH, and spectrofluorimetry, fluorescence microscopy, or how cytometry as quantification technique. All have major disadvantages, including either a slow or inaccurate response. In the present study, pH determination was achieved on J774-cell phagosomes containing dual-labeled zymozan particles using dual fluorescence flow cytometry with an argon-ion laser excitation wavelength at 488 nm. This allowed zymozan-containing macrophages to be distinguished from other cells and their fluorescence to be measured rapidly. The use of a new probe, namely Oregon Green 488 which has a pK(alpha) lower than carboxyfluorescein with the same maximum excitation and emission wavelengths, allowed investigation of pH value below 5. The dual labeling with Oregon Green 488 and carboxytetramethylrhodamine as pH-sensitive and pH-insensitive probes, respectively, overcame the absence of an isobestic point in the Oregon Green 488 spectrum. The phagosomal pH was determined using a calibration curve of phagosomal pH established by adding ionophores in phagocyte suspension and measuring the fluorescence intensity ratio (535 nm/585 nm) for different pHs. A phagosomal pH of 4.5 +/- 0.1 can be accurately determined. This method permits pH measurements down to 4, even in the presence of nonengulfed reporter particles. (C) 1998 Academic Press.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 50 条
  • [31] FLUORESCENCE FLOW-CYTOMETRY AND IMMUNOLOGY APPLIED TO CANCER
    WUNDERLICH, J
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1987, 9 (02): : 133 - 137
  • [32] COMPARATIVE-ANALYSIS OF SURFACE-MEMBRANE IMMUNOGLOBULIN DETERMINATION BY FLOW-CYTOMETRY AND FLUORESCENCE MICROSCOPY
    GEBHARD, DF
    MITTELMAN, A
    CIRRINCIONE, C
    THALER, HT
    KOZINER, B
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1986, 34 (04) : 475 - 481
  • [33] Toward quantitative fluorescence measurements with multicolor flow cytometry
    Wang, Lili
    Gaigalas, Adolfas K.
    Marti, Gerald
    Abbasi, Fatima
    Hoffman, Robert A.
    CYTOMETRY PART A, 2008, 73A (04) : 279 - 288
  • [34] Fluorescence staining and flow cytometry for monitoring microbial cells
    Veal, DA
    Deere, D
    Ferrari, B
    Piper, J
    Attfield, PV
    JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 243 (1-2) : 191 - 210
  • [35] Microfluidic fluorescence in situ hybridization and flow cytometry (μFlowFISH)
    Liu, Peng
    Meagher, Robert J.
    Light, Yooli K.
    Yilmaz, Suzan
    Chakraborty, Romy
    Arkin, Adam P.
    Hazen, Terry C.
    Singh, Anup K.
    LAB ON A CHIP, 2011, 11 (16) : 2673 - 2679
  • [36] FLUORESCENCE QUENCHING - A PRACTICAL PROBLEM IN FLOW-CYTOMETRY
    CHAPPLE, MR
    JOHNSON, GD
    DAVIDSON, RS
    JOURNAL OF MICROSCOPY-OXFORD, 1990, 159 : 245 - 253
  • [37] Visible and near infrared fluorescence spectral flow cytometry
    Nolan, John P.
    Condello, Danilo
    Duggan, Erika
    Naivar, Mark
    Novo, David
    CYTOMETRY PART A, 2013, 83A (03) : 253 - 264
  • [38] Endogenous fluorescence lifetime of viable cells by flow cytometry
    Houston, Jessica P.
    Naivar, Mark
    Martin, John C.
    Goddard, Greg
    Carpenter, Susan
    Mourant, Judith R.
    Freyer, James P.
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES VI, 2008, 6859
  • [39] Digital Analysis and Sorting of Fluorescence Lifetime by Flow Cytometry
    Houston, Jessica P.
    Naivar, Mark A.
    Freyer, James P.
    CYTOMETRY PART A, 2010, 77A (09) : 861 - 872
  • [40] Size and fluorescence measurements of individual droplets by flow cytometry
    Fattaccioli, Jacques
    Baudry, Jean
    Emerard, Jean-Daniel
    Bertrand, Emanuel
    Goubault, Cecile
    Henry, Nelly
    Bibette, Jerome
    SOFT MATTER, 2009, 5 (11) : 2232 - 2238